Strength Analysis and Standardization for Closed Chocks by Using the Finite Elements Method (유한요소법을 이용한 클로즈드 초크의 구조검증 및 표준화에 대한 연구)

  • Jung, Jae-Wook;Lee, Byung-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.2
    • /
    • pp.132-145
    • /
    • 2012
  • Mooring fittings mean various devices and fittings to safely fasten vessels to quays, jetties and sea-floating buoys, etc. They include mooing winches, capstans, chocks, fairleads, guide rollers, bollards, and bitts. Not only the seats and reinforced parts for the installation of fittings but also ropes and chains for mooring and chain stoppers can be also considered. Because of damages to mooring fittings during mooring directly related to large-scale accidents such as the drifting of vessels, mooring fittings with strength appropriate for the physical features of the vessels must be installed. The reinforcement of the vessels on which the mooring fittings are installed must be designed to withstand the loads transferred from the fittings as well. Also mooring fittings with efficient strength should be required because damaged ships lead to sea pollution such as oil or fuel oil spillage. This study has been performed by the Finite Element Method for two aspects of closed chocks which are divided into structure-supporting shapes and working load. In the case of structure-supporting shapes, they have been performed in the field of sheet and bulwark. As for working load, it has been analyzed according to working load direction such as chock's side and below. At first, strength analysis for unique closed chocks has been carried out by using the Finite Element Method, they are applied for the situation when vessels pass by the panama canal. And then the experiment has been done to verify the analyzed date obtained by FEM. The experimental results were found to be similar to the numerical results with up to 16% difference. On the basis of the results obtained, standardization has been carried out by the Finite Element Method for various sizes of closed chocks.

A Study on the Development and Strength Evaluation of the Mooring Fittings with Big Capacity (선박용 대형 계류장비의 개발과 강도 평가)

  • Kim, Young-sig;Kim, Ul-nyeon;Kim, Mi-hee;Kim, Kyoung-youn
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.1-7
    • /
    • 2017
  • It has been developed large mooring fittings having the capacity of 160 tons and 180 tons installed on 170K LNG FSRU. The finite element analysis for the mooring fittings was carried out in order to check the structural integrity and to confirm satisfaction of the rule requirements. The 3 kinds of mooring fittings such as chock, bollard and universal fairlead are selected for FE analysis and load test. According to the FE analysis results, all the stress levels satisfied the acceptance criteria guided by the IACS UR A2, ISO standard, ship rules and OCIMF. As test results under design load, no structural defects were found.

  • PDF

A Study on the Evaluation of Mooring Safety of LNG Ships (LNG선의 계류 안전성의 평가에 관한 연구)

  • 김세원
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.5
    • /
    • pp.373-383
    • /
    • 2000
  • The ship’s safe mooring stability is a principles for the safe cargo handling works at the mooring berth. Today numerous standards, guidelines and recommendations concerning mooring practices, fittings and equipments exist throughout the worldwide maritime industries. In recently, the mooring facilities were constructed as dolphin types at the open sea area apart far from shoreside instead of enclosed coastline area in accordance with increasing ship’s size and for preventing environmental pollution. Therefore the exciting wave condition must be considered as a basic environmental criteria with the wind force and current force for all of the mooring ships at the sea berth facilities. In this study, this added wave force as one of the environmental external forces by using the theoretical formula was applied to the LNG ship in Pyeongtaeg harbor needed the special mooring stability of the sea berth. Through this research, it can be confirmed that wave force is the very important factor in the mooring force and the strength of wave force works much more in the full laden condition than in the lightship condition. And also the wave force changes to non-linear states according to the wave frequency and wave length. In addition, the maximum limit criteria of environmental force of prohibiting the entering ship on the berth and loading works controlled by the port authority concerned of Pyeongtaeg port fully satisfies the condition of the mooring limit force recommended by OCIMF that the safe permitted force of the mooring line have to be within 55 % of MBL.

  • PDF

Development of the Large-Capacity Mooring Fittings according to MEG4(Mooring Equipment Guideline 4) (MEG4(Mooring Equipment Guideline 4) 적용에 따른 대용량 무어링 피팅 개발)

  • Myung-Su Yi;Kwang-Cheol Seo;Joo-Shin Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.950-957
    • /
    • 2023
  • For safe mooring and towing between the ship and port, the equipment must be designed in accordance with the relevant international regulations. However, some small shipyards and engineering companies often do not fully comprehend the core contents. Therefore, the international regulations regarding towing and mooring equipment are reviewed and the bollard and chock are newly developed based on the Mooring Equipment Guideline 4 (MEG4) standards. A bollard is a mooring equipment used to fix a mooring rope to the hull. It has two columns and is mostly used in a figure eight pattern knots under the mooring condition. The chock, which is used to change the mooring rope direction coming into the ship from outside, is manufactured using a casting with curvature. The two mooring equipment are widely used in the stern, bow, and mid-side. Owing to the increase in the size of container vessels and LNG ships, the mooring rope load has increased and the safe working load of the mooring equipment must be revised. This study summarizes and examines the results of the allowable stress method obtained using finite element analysis modelling. To consider the mesh size effect, a reasonable criteria was suggested by referring the existing class guidance. Additionally, the safe working load was verified through nonlinear collapse analysis, and the elastic region against load increments was confirmed. Furthermore, the proposed evaluation method can be used to develop similar equipment in the near future.

Ultimate Strength Assessment of Bollard and Its Foundation Considering Production Costs (생산성을 고려한 볼라드 및 볼라드 지지 구조의 최종강도 평가)

  • Oh, Chang-Min;Choung, Joon-Mo;Cho, Sang-Rai
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.5 s.149
    • /
    • pp.604-610
    • /
    • 2006
  • Common structural rules of JBP(Joint Bulker Project) and JTP(Joint Tanker Project), which will come into effect in 2006, invoke the necessity of the ultimate limit state(ULS) design for ship structures. Even though the many applications of ULS analysis have been performed for ship structures, there have few studies carried out for deck machineries and their supporting structures. Recently four major Korean shipbuilders(DSME, HHI, HHIC, SHI) jointly developed and proposed a new design standards for mooring fittings and also proposed the SWL (Safety Working Load) obtained based on the first yield criterion. In this study, various ultimate strength analyses were performed for bollards and their foundation structures whose yield strengths were quantified by the research consortium. Prior to performing the ultimate strength analyses, the numerical calculation method was substantiated with the test results provided in the joint work report. Based upon the results of this study, it can be concluded that the reinforcements to increase the yield strength are not always resulted in the enhancement of the ultimate strength. Furthermore, the additional production costs for the reinforcements can not be rewarded by the ultimate strength. Therefore, another alternative arrangements should be developed in the view point of ultimate strength.