• 제목/요약/키워드: Monte-Carlo(MC)

검색결과 217건 처리시간 0.025초

확률론적 파괴역학을 도입한 CANDU 압력관의 예리한 결함에 대한 건전성평가 (Integrity Assessment of Sharp Flaw in CANDU Pressure Tube Using Probabilistic Fracture Mechanics)

  • 이준성;곽상록;김영진;박윤원
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.653-659
    • /
    • 2002
  • This paper describes a probabilistic fracture mechanics(PFM) analysis based on Monte Carlo(MC) simulation. In the analysis of CANDU pressure tube, the depth and aspect ratio of an initial semi-elliptical surface crack, a fracture toughness value and delayed hydride cracking(DHC) velocity are assumed to be probabilistic variables. As an example, some failure probabilities of piping and CANDU pressure tube are calculated using MC method with the stratified sampling MC technique, taking analysis conditions of normal operations. In the stratified MC simulation, a sampling space of probabilistic variables is divided into a number of small cells. For the verification of analysis results, a comparison study of the PFM analysis using other commercial code is carried out and a good agreement was observed between those results.

심층 신경망을 이용한 실시간 유도탄 파편 탄착점 및 분산 추정 (Real-Time Estimation of Missile Debris Predicted Impact Point and Dispersion Using Deep Neural Network)

  • 강태영;박국권;김정훈;유창경
    • 한국항공우주학회지
    • /
    • 제49권3호
    • /
    • pp.197-204
    • /
    • 2021
  • 유도탄의 비행 시험 중 고장 또는 비정상적인 기동이 발생하는 경우 비행을 계속하지 않도록 의도적으로 자폭한다. 이때 파편이 발생하며 안전 지역을 벗어났는지 여부를 실시간으로 추정하는 것이 중요하다. 본 논문에서는 Fully-Connected Neural Network(FCNN)를 이용하여 실시간으로 파편의 예상 낙하 영역 및 낙하 시간을 추정하는 방법을 제안한다. 많은 양의 학습 데이터 생성을 위해 Unscented Transform(UT)를 적용하였으며 신뢰도 확보를 위해 Monte-Carlo(MC) 시뮬레이션과 비교하여 파라미터를 선정하였다. 또한 제안한 방법의 추정 결과를 MC와 비교하여 성능을 분석하였다.

MCS를 이용한 고수위 수위-유량관계곡선의 연장에 관한 연구 (Extension of Rating Curve for High Water Level using Monte Carlo Simulation)

  • 문영일;김종석;윤선권
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.683-686
    • /
    • 2008
  • Flood damage has been increased due to the abnormal climate and extreme rainfall. So, quantitative and qualitative hydrologic data should be improved in oder to enhance accuracy of hydrologic forecast. However, research regarding hydrologic data have not been thorough enough. Therefore, in this study, monte carlo simulation was applied to rainfall runoff model to improve the reliability of runoff analysis and risk analysis. Rainfall-Stage-Discharge curve was developed as a consequence of MCS and it is possible to get correct rating curve for high water level.

  • PDF

의학물리 분야에 사용하기 위한 PMCEPT 몬테카를로 도즈계산용 코드 검증 (Verification of the PMCEPT Monte Carlo dose Calculation Code for Simulations in Medical Physics)

  • 금오연
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.21-34
    • /
    • 2008
  • 환자의 CT자료를 기반으로 만들어진 3차원상의 표적물질에 전자 및 광자의 전달 현상을 계산하는 몬테카를로(MC) 도즈계산용 병렬프로그램 (PMCEPT 코드)을 개발하여 베어울프 PC 클러스터에 탑제하였다. 시뮬레이션에서 오차를 최소화하고 코드를 더욱 발전시키기 위해서는 현재의 MC 코드의 한계를 아는 것이 매우 유익하다. 이러한 관점에서 저자는 PMCEPT코드를 이용하여 이질 혹은 동질의 표적물질에서 표준화된 깊이 도즈를 계산하여 잘 알려진 다른 코드들, MCNP5, EGS4, DPM, GEANT4 및 실험결과와 비교를 하였다. PMCEPT결과는 이질 혹은 동질의 표적에서 다른 코드들과 $1{\sim}3%$ 오차 범위 안에서 잘 일치하였다. 계산시간 비교에 있어서도 PMCEPT 코드가 MCNP5 보다는 약 20배, GEANT4코드보다는 약 3배정도 빨랐다. 이러한 결과를 종합하면, PMCEPT코드는 의학물리분야의 시뮬레이션 코드로 사용하기에 매우 좋은 것으로 사료된다.

  • PDF

확률론적 파괴역학 수법의 적용성 검토 (Application of Probabilistic Fracture Mechanics Methodology)

  • 이준성;곽상록;김영진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.667-670
    • /
    • 2001
  • For major structural components periodic inspections and integrity assessments are needed for the safety. However, many flaws are undetectable because sampling inspection is carried out during in-service inspection. Probabilistic integrity assessment is applied to take into consideration of uncertainty and variance of input parameters arise due to material properties and undetectable cracks. This paper describes a Probabilistic Fracture Mechanics(PEM) analysis based on the Monte Carlo(MC) algorithms. Taking a number of sampling data of probabilistic variables such as fracture toughness value, crack depth and aspect ratio of an initial surface crack, a MC simulation of failure judgement of samples is performed. For the verification of this analysis, a comparison study of th PFM analysis using a commercial code, mathematical method is carried out and a good agreement was observed between those results.

  • PDF

Analysis of Interference between UWB and ITS

  • Park, Se-Ho;Kim, Eun-Cheol;Kim, Jin-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제9권4호
    • /
    • pp.202-210
    • /
    • 2009
  • In this paper, we have analyzed the effect of interference between ultra-wideband(UWB) and intelligent transport systems(ITS). The maximum possible UWB emission power and minimum possible distance between UWB devices and ITS are found. In order to analyze the interference, we employ the Monte-Carlo(MC) method. We consider six situations, which are indoor office line-of-sight(LOS), indoor office non-line-of-sight(NLOS), indoor residential LOS, indoor residential NLOS, outdoor rural LOS, and outdoor rural NLOS environments. From the simulation results, it is confirmed that coexistence between UWB and ITS devices can be realized in accordance with the emission mask of 19.3 dB for indoor application or 19.3 dB for an image system. And in the outdoors, coexistence between UWB and ITS devices can be realized if the emission mask is at least 1.6 dB for vehicles' radar systems.

원전 주요기기의 확률론적 평가 기법 (Probabilistic Evaluation Methodology for Nuclear Components)

  • 이준성;곽상록;김영진;박윤원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.459-464
    • /
    • 2001
  • For major nuclear power plant components periodic inspections and integrity assessments are needed for the safety. But many flaws are undetectable due to sampling inspection. Probabilistic integrity assessment is applied to take into consideration of uncertainty and variance of input parameters arise due to material properties, applied load and undetectable flaws. This paper describes a Probabilistic Fracture Mechanics(PFM) analysis based on Monte Carlo(MC) algorithms. Taking important parameters as probabilistic variables such as fracture toughness, crack growth rate and flaw shape, failure probability of major nuclear power plant components is archived as a results of MC simulation. For the verification of these analysis, a comparison study of the PFM analysis using other commercial code, mathematical method is carried out and a good agreement was observed between those results.

  • PDF

2D random walk와 세포 확산 비교 연구

  • 권태진
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.53-60
    • /
    • 2015
  • 본 연구에서는 random walk하는 입자와 암세포 확산을 비교하여 Fick's law를 따르는 확산 모형과 암세포 확산의 차이를 밝힌다. 암세포 확산은 암 전이 메커니즘을 이해하는데 매우 중요하다. 하지만 아직까지 암세포 확산은 정확하게 이해되지 않고 있다. 따라서 이번 연구에서는 가장 간단한 2차원 random walk와 암세포 확산을 비교하고, 동역학적인 차이를 규명해 암세포 확산을 이해하고자 한다. Random walk하는 입자는 EDISON 전산화학 전문센터의 프로그램 중 dynamic Monte Carlo(dynamic MC) 전산 모사 소프트웨어를 이용하여 2차원에서 움직이는 레나드-존스 입자의 운동을 통해 살펴보았다. 암세포 확산은 실제 암세포의 시간에 따른 위치 변화 정보 (세포의 궤적)를 직접 구하여 분석하였다. Dynamic MC 결과는 Fickian 확산 모형을 잘 따르는 것을 평균 제곱 거리와 밀도 함수를 통해 확인할 수 있었다. 암세포 확산의 경우 평균 제곱 거리는 시간에 대해서 선형적으로 비례하지만 밀도 함수는 가우시안 형태로 나오지 않으며 Fick's law를 따르는 확산 모형과 다른 확산 형태를 보인다. 이러한 확산 형태는 암세포의 동역학적인 다양성 때문에 나타나며 각각의 암세포가 다른 운동성을 가지는 것에 기인하는 것으로 보인다.

  • PDF

ZEP520 포토리지스트를 이용한 나노 패턴 형성을 위한 전자빔 리소그래피 공정 모델링 및 시뮬레이션 (Modeling and Simulation of Electron-beam Lithography Process for Nano-pattern Designs using ZEP520 Photoresist)

  • 손명식
    • 반도체디스플레이기술학회지
    • /
    • 제6권3호
    • /
    • pp.25-33
    • /
    • 2007
  • A computationally efficient and accurate Monte Carlo (MC) simulator of electron beam lithography process, which is named SCNU-EBL, has been developed for semiconductor nanometer pattern design and fabrication. The simulator is composed of a MC simulation model of electron trajectory into solid targets, an Gaussian-beam exposure simulation model, and a development simulation model of photoresist using a string model. Especially for the trajectories of incident electrons into the solid targets, the inner-shell electron scattering of an target atom and its discrete energy loss with an incident electron is efficiently modeled for multi-layer resists and heterogeneous multi-layer targets. The simulator was newly applied to the development profile simulation of ZEP520 positive photoresist for NGL(Next-Generation Lithography). The simulation of ZEP520 for electron-beam nanolithography gave a reasonable agreement with the SEM experiments of ZEP520 photoresist.

  • PDF

Molecular Modeling of the Chiral Recognition of Propranolol Enantiomers by a β-Cyclodextrin

  • Kim, Hyun-myung;Jeong, Karp-joo;Lee, Sang-san;Jung, Seun-ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.95-98
    • /
    • 2003
  • Enantioselectivity of the propranolol on β-cyclodextrin was simulated by molecular modeling. Monte Carlo (MC) docking and molecular dynamics (MD) simulations were applied to investigate the molecular mechanism of enantioselective difference of both enantiomeric complexes. An energetic analysis of MC docking simulations coupled to the MD simulations successfully explains the experimental elution order of propranolol enantiomers. Molecular dynamics simulations indicate that average energy difference between the enantiomeric complexes, frequently used as a measure of chiral recognition, depends on the length of the simulation time. We found that, only in case of much longer MD simulations, noticeable chiral separation was observed.