• Title/Summary/Keyword: Monte Carlo 모사기법

Search Result 47, Processing Time 0.026 seconds

Air-traffic dispatching scheduling in terminal airspace (공항접근영역 항공교통 Dispatching 스케줄링 연구)

  • Jeong, Sun-Jo;Cho, Doo-Hyun;Choi, Han-Lim
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.11
    • /
    • pp.973-980
    • /
    • 2016
  • An air traffic management (ATM) has been studied in a variety of fields to utilize an air traffic capacity efficiently and solve a congested air traffic situation due to an increment of an air traffic demand. In this paper, an air traffic management, which is related with controlling and determining the sequencing of an aircraft approaching to an airport, in terminal control area is studied. This paper focuses on scheduling algorithms with a given problem for the air traffic management with operational constraints, such as a space separation, an overtaking on the same air-route, and a route merge point (a scheduling point). For a real-time calculation, the presented algorithms focus on dispatching heuristic rules which are able to assign tasks in a fast time period with an adequate performance, which can be demonstrated as a proper and realistic scheduling algorithm. A simulation result is presented to illustrate the validity and applicability of the proposed algorithm. Each scheduling rule is analyzed on the same static and dynamic air traffic flow scenario with the ATM Monte-Carlo simulation.

Simulation of Low-Density Gas Flows

  • 정찬홍
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.19-28
    • /
    • 2004
  • 유동장의 특성을 구분할 수 있는 척도는 평균자유행로와 특성거리의 비인 누센수이다. 누센수에 따라서 유장은 연속체영역, 미끄럼영역, 천이영역, 및 자유분자영역으로 나누어진다. 고고도에서 비행체 주위의 유동장, 진공에서의 유동장 등이 비연속체영역 즉 저밀도유동장에 해당된다. 비연속체영역에 해당되는 또 다른 중요한 분야는 미세 유동장이다. 최근에 관심이 대두되고 있는 미세항공기(MAV)와 실리콘혁명 이래 유망한 미래기술중의 하나인 MEMS 장치 주위의 유동장 등이 바로 미세 유동장이다. 비연속체영역에서 유체의 이동 및 전달현상을 기술하기 위하여는 Boltzmann 방정식을 해석하여야한다. Navier-Stokes 방정식을 이용한 기존의 CFD 기법이 적용되지 않는 새로운 유동영역이기 때문이다. 본 발표에서는 Boltzmann 방정식의 유력한 해법인 직접모사(Direct Simulation Monte Carlo)법을 이용한 저밀도 유동장 해석이 소개될 것이다. 또한 직접모사법이 이용되기 어려운 다양한 저속 유동장에 대한 해석결과도 소개될 것이다.

  • PDF

Study on the Thruster Plume Behaviors using Preconditioned Scheme and DSMC Method (예조건화 기법과 직접모사법을 이용한 추력기 플룸 거동에 관한 연구)

  • Lee, Kyun-Ho;Kim, Su-Kyum;Yu, Myoung-Jong
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.144-153
    • /
    • 2009
  • To study the plume effects in the rarefied region, the Direct Simulation Monte Carlo(DSMC) method is usually adopted because the plume field usually contains the entire range of flow regime from the near-continuum in the vicinity of nozzle exit through transitional state to free molecular at far field region from the nozzle. The objective of this study is to investigate the behaviors of a small monopropellant thruster plume in the rarefied region numerically using DSMC method. To deduce accurate results efficiently, the preconditioned scheme is introduced to calculate continuum flow fields inside thruster to predict nozzle exit properties used for inlet conditions of DSMC method. By combining these two methods, the rarefied flow characteristics of plume such as strong nonequilibrium near nozzle exit, large back flow region, etc, can be investigated.

  • PDF

Study on Small Thruster Plume using Preconditioned Continuum Scheme and DSMC Method in Vaccum Area (희박영역에서 예조건화 연속체기법과 직접모사법을 이용한 소형 추력기 플룸 거동에 관한 연구)

  • Lee, Kyun-Ho;Lee, Sung-Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.9
    • /
    • pp.906-915
    • /
    • 2009
  • To study the plume effects in the vacuum area, the Direct Simulation Monte Carlo(DSMC) method is usually adopted because the plume field usually contains the entire range of flow regime from the near-continuum in the vicinity of nozzle exit through transitional state to free molecular at far field region from the nozzle. The objective of this study is to investigate the behaviors of a small monopropellant thruster plume in the vacuum area numerically using DSMC method. To deduce accurate results efficiently, the preconditioned scheme is introduced to calculate continuum flow fields inside thruster to predict nozzle exit properties used for inlet conditions of DSMC method. By combining these two methods, the vacuum flow characteristics of plume such as strong nonequilibrium near nozzle exit, large back flow area, etc, can be investigated.

A Monte Carlo Study of Dose Enhancement with kilovoltage and megavoltage photons (몬테칼로 기법을 이용한 kV, MV X선에서의 선량증가 효과 비교 평가)

  • Hwang, ChulHwan;Im, In-Chul;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • Monte Carlo simulations were used to assess dose enhancement effects for 60-, 90-, 120-, and 150-kV X-rays, and for 6- and 15-MV X-rays. The MCNPX code was used for a computer simulation of the ICRU slab phantom, and gold, gadolinium, and iron oxide (Fe2O3) were employed as dose enhancement agents. In consideration of the buildup region of the incident energy, agent concentrations of 5, 10, 15, and 20 mg/g were inserted on the surface of the phantom at a depth of 5 cm. Based on baseline values obtained in the absence of dose enhancement agents, a quantitative analysis was performed by evaluating depth-dependent changes in the absorbed energy and the dose enhancement factor (DEF). A higher concentration of dose enhancement agents led to a greater dose enhancement effect with iron oxide, gadolinium, and gold in descending order. For kilovoltage (kV) X-rays, as the incident energy was decreased and as the energy became closer to the ionization potential of the atoms in the enhancement agent, the dose enhancement effect increased. In the megavoltage (MV) X-ray range, dose enhancement was higher at 6 MV compared with 15 MV. However, the overall dose enhancements were significantly lower compared to the results obtained with kV X-rays.

Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target (이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사)

  • Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.107-114
    • /
    • 2023
  • X-ray fluorescence analysis has been widely used in the field of science and industry because it gives information about elements and their concentrations without destruction of samples. To increase analysis accuracy of fluorescence generated by photons of the transmission-type X-ray tube for mixture and compound samples would be recommend to have strong energy near 10 keV and 20 keV simultaneously. Tungsten of 9.65 keV and molybdenum of 17.48 keV were considered as targets with dual deposition structure for obtaining two strong characteristic X-rays, and the transmission-type X-ray tube was analyzed using Geant4 Monte Carlo simulation. The W-Mo structure resulted in strong characteristic X-ray near 10 keV and 20 keV simultaneously. A structure with Mo-W multilayers of 5 ㎛ thick also gave optimal spectrum. Various material combination and thickness optimization for the dual-structured target can give X-ray spectrum with strong characteristic X-ray of specific energies.

Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste (배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가)

  • Kim Gye-Hong;Oh Won-Zin;Lee Kune-Woo;Seo Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

  • PDF

A Monte Carlo Study of Dose Enhancement according to the Enhancement Agents (몬테칼로 기법을 이용한 방사선 선량증가 물질에 따른 선량증가 효과 평가)

  • Kim, Jung-Hoon;Kim, Chang-Soo;Hwang, Chulhwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.93-99
    • /
    • 2017
  • Dose enhancement effects at megavoltage (MV) X and ${\gamma}-ray$ energies, and the effects of different energy levels on incident energy, dose enhancement agents, and concentrations were analyzed using Monte Carlo simulations. Gold, gadolinium, Iodine, and iron oxide ($Fe_2O_3$) were compared as dose enhancement agents. For incident energy, 4, 6, 10 and 15 MV X-ray spectra produced by a linear accelerator and a Co-60 ${\gamma}-ray$ were used. The dose enhancement factor (DEF) was calculated using an ICRU Slab phantom for concentrations of 7, 18, and 30 mg/g. The DEF was higher at higher concentrations of dose enhancement agents and at lower incident energies. The calculated DEF ranged from 1.035 to 1.079, and dose enhancement effects were highest for iron oxide, followed by iodine, gadolinium, and gold. Thus, this study contributes to improving the therapeutic ratio by delivering larger doses of radiation to tumor volume, and provides data to support further in vivo and in vitro studies.

Development of Stochastic Finite Element Model for Underground Structure with Discontinuous Rock Mass Using Latin Hypercube Sampling Technique (LHS기법을 이용한 불연속암반구조물의 확률유한요소해석기법개발)

  • 최규섭;정영수
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.143-154
    • /
    • 1997
  • Astochastic finite element model which reflects both the effect of discontinuities and the uncertainty of material properties in underground rock mass has been developed. Latin Hypercube Sampling technique has been mobilized and compared with the Monte Carlo simulation method. To consider the effect of discontinuities, the joint finite element model, which is known to be suitable to explain faults, cleavage, things of that nature, has been used in this study. To reflect the uncertainty of material properties, multi-random variables are assumed as the joint normal stiffness and the joint shear stiffness, which could be simulated in terms of normal distribution. The developed computer program in this study has been verified by practical example and has been applied to analyze the circular cavern with discontinuous rock mass.

  • PDF

Application of Probabilistic Technique for the Development of Fire Accident Scenarios in Railway Tunnel (확률론적 기법을 활용한 철도터널의 화재사고 시나리오의 구성)

  • 곽상록;홍선호;왕종배;조연옥
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.302-306
    • /
    • 2004
  • Many long railway tunnels without emergency evacuation system or ventilation system are under construction or in-use in Korea. In the case of tunnel-fire, many fatalities are occur in current condition. Current safety level is estimated in this study, for the efficient investment on safety. But so many uncertainties in major input parameters make the safety estimation difficult. In this study, probabilistic techniques are applied for the consideration of uncertainties in major input parameters. As results of this study, accident scenarios and survival ratio under tunnel fire accident are determined for various conditions.