Effects of Nozzle Locations on the Rarefied Gas Flows and Al Etch Rate in a Plasma Etcher (플라즈마 식각장치내 노즐의 위치에 따른 희박기체유동 및 알루미늄 식각률의 변화에 관한 연구)

  • 황영규;허중식
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1406-1418
    • /
    • 2002
  • The direct simulation Monte Carlo(DSMC) method is employed to calculate the etch rate on Al wafer. The etchant is assumed to be Cl$_2$. The etching process of an Al wafer in a helicon plasma etcher is examined by simulating molecular collisions of reactant and product. The flow field inside a plasma etch reactor is also simulated by the DSMC method fur a chlorine feed gas flow. The surface reaction on the Al wafer is simply modelled by one-step reaction: 3C1$_2$+2Allongrightarrow1 2AIC1$_3$. The gas flow inside the reactor is compared for six different nozzle locations. It is found that the flow field inside the reactor is affected by the nozzle locations. The Cl$_2$ number density on the wafer decreases as the nozzle location moves toward the side of the reactor. Also, the present numerical results show that the nozzle location 1, which is at the top of the reactor chamber, produces a higher etch rate.

Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation (확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구)

  • Lee , Cheol-MIn;Kim , Yoon-Shin;Lee , Tae-Hyung;Kim , Jong-Cheol;Kim , Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

Study on Levenberg-Marquardt for Target Motion Analysis (표적기동분석을 위한 Levenberg-Marquardt 적용에 관한 연구)

  • Cho, Sunil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.148-155
    • /
    • 2015
  • The Levenberg-Marquardt method is a well known solution about the least square problem. However, in a Target Motion Analysis(TMA) application most of researches have used the Gauss-Newton method as a batch estimator, which of inverse matrix calculation may causes instability problem. In this paper, Levenberg-Marquardt method is applied to TMA problem to prevent its divergence. In experiment, its performance is compared with Gauss-Newton in domain of range, course and speed. Monte Carlo simulation reveals the convergence time and reliability of the TMA based on Levenberg-Marquardt.

Feasibility of the 3D Printing Materials for Radiation Dose Reduction in Interventional Radiology (인터벤션 시술 시 환자의 선량감소를 위한 3D 프린팅 재료의 적용성 평가)

  • Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.169-176
    • /
    • 2020
  • Interventional radiology is performed under real-time fluoroscopy, and patients are exposed to a wide range of exposures for a long period of time depending on the examination and procedure. However, studies on radiation protection for patients during an intervention are insufficient. This study aims to evaluate the doses exposed during the intervention and the applicability of 3D printing materials. The organ dose for each intervention site was evaluated using a monte carlo simulatio. Also, the dose reduction effect of the critical organs was calculated when using a shielding device using 3D printing materials. As a result, the organ dose distribution for each intervention site showed a lower dose distribution for organs located far from the x-ray tube. It was analyzed that the influence of scattered rays was higher in the superficial organs of the back of the human body where x-rays were incident. The dose reduction effect on the critical organ using the 3D printing shield showed the highest testis among the gonads, and in the case of other organs, the dose reduction effect gradually decreased in the order of the eye, thyroid, breast, and ovary. Accordingly, it is judged that the 3D printed shield will be sufficiently usable as a shielding device for the radiation protection of critical organs.

Stochastically Dependent Sequential Acceptance Sampling Plans

  • Kim, Won-Kyung
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.3
    • /
    • pp.22-38
    • /
    • 1997
  • In a traditional sequential acceptance sampling plan, it is assumed that the sampled items are independent each other. In this paper, stochastically dependent sequential acceptance sampling plans are dealt when there exists dependency between sampled items. Monte-Calro algorithm is used to find the acceptance and rejection probabilities of a lot. The number of defectives for the test to be accepted and rejected in probability ratio sequential test can be found by using these probabilities. The formula for measures of performance of these sampling plans is developed. Type I and II error probabilities are estimated by simulation. This research can be a, pp.ied to sequential sampling procedures in place of control charts where there is a recognized and necessary dependency during the production processes. Also, dependent multiple acceptance sampling plans can be derived by extending this sequential sampling procedure. As a numerical example, a Markov dependent process model is given, and the characteristics of the sampling plans are examined according to the change of the dependency factor.

  • PDF

Structural Reliability Analysis of the Roket Motor Case considering Uncertainties in Material Properties (재료물성치의 분포를 고려한 로켓모터케이스의 구조 신뢰성 해석)

  • Ro, Young-Hee;Goo, Song-Hoe
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.523-526
    • /
    • 2011
  • This is concerned with the structural reliability analysis(RA) considering uncertainties in material properties. This method is performed by the stochastic process using Kriging with calculating the distribution of probability and equation of limit state for saving calculated and analyzed time. The proposed methodology is applied to the rocket motor case and compared with monte-calro simulation in efficiency and accuracy of this process.

  • PDF

Analysis of Electron Energy Distribution Function and Transport Characteristic in SiH$_4$ Gas Plasma by MCS-BE Method (MCS-BE법을 이용한 SiH$_4$가스 프라즈마중의 전자에너지분포함수와 수송특성해석)

  • 이형윤;하성철;유회영;김상남;임상원;문기석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.154-159
    • /
    • 1997
  • This paper describes the electron transport characteristic in SiH$_4$ gas calculated for range of E/N values from 0.5~300(Td) by the Monte Calro simulation and Boltzmann equation method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters are obtained for TOF method. The results gained that the value of an electron swarm parameter such as the electron drift velocity, the electron ionization coefficients longitudinal and transverse diffusion coefficients, characteristics energy agree with thee experimental and theoretical for a range of E/N. The electron energy distributions function were analysed in monosilane at EN : 30, 50(Td) for a case of equilibrium region in the mean electron energy. The validity of the results obtained has been confirmed by a TOF method.

  • PDF

Sub-pixel Evaluation with Frequency Response Analysis

  • OKAMOTO Koji
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.14-22
    • /
    • 2001
  • The frequency responses on the sub-pixel evaluation technique were investigated using the Monte-calro Simulation technique. The frequency response by the FFT based cross-correlation gives very good results, however, the gain loss does exist for the small displacement, (less than 0.5 pixel). While, the no gain loss is observed in the Direct Cross-correlation, however, the sub-pixel accuracy was limited to be about 0.1 pixel, i.e., it could not detect the small displacement. To detect the higher accurate sub-pixel displacement, the gradient based technique is the best. For the small interrogation area (e.g., 4x4), only the gradient technique can detect the small displacement correctly.

  • PDF

Monte Carlo Simulation for Development of Diagnostic Multileaf Collimator (진단용 다엽콜리메이터 개발을 위한 몬테칼로 시뮬레이션 연구)

  • Han, Su-Chul;Park, Seungwoo
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.595-600
    • /
    • 2016
  • The diagnostic multileaf collimator(MLC) was designed for patient dose reduction in diagnostic radiography We used monte carlo simulation code (MCNPX, LANL, USA) to evaluate efficiency of shielding material for making diagnostic MLC as preliminary study. The diagnostic radiography unit was designed using SRS-78 program according to tube voltage (80,100,120 kVp) and acquired energy spectrums. The shielding material was SKD11 alloy tool steel that is composed of 1.6% carbon(C), 0.4% silicon(Si), 0.6% manganese (Mn), 5% chromium (Cr), 1% molybdenum(Mo) and vanadium(V). The density of it was $7.89g/cm^3$.Using tally card 6, we calculated the shielding efficiency of MLC according to tube voltage. The results was that 98.3% (80 kVp), 95.7 %(100 kVp), 93.6% (120 kVp). We certified efficiency of diagnostic MLC fabricated from SKD11 alloy steel by monte calro simulation. Based on the results, we designed the diagnostic MLC and will develop the diagnostic MLC for reduction of patient dose in diagnostic radiography.

Li2O and Li2CO3 Thin Film Growth by LPMOCVD (LPMOCVD에 의한 Li2O 및 Li2CO3 박막의 증착)

  • Jung, Sang-Chul;Ahn, Ho-Geun;Imaishi, Nobuyuki
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.225-230
    • /
    • 1999
  • Low pressure metal organic chemical vapor deposition (LPMOCVD) of $Li_2O$ solid thin films from Li(DPM) in nitrogen-oxygen or argon-oxygen atmosphere was experimentally investigated by using a small hot wall tubular type reactor. XRD and ESCA analysis revealed that $Li_2CO_3$ film grew in nitrogen-oxygen atmosphere and $Li_2O$ grew in argon-oxygen atmosphere. The grown lithium oxide or carbonate reacted with silicon or silica base materials to produce silicates. The CVD model analysis by means of the well-known micro trench method and Monte Carlo simulation was not fully successful, but a set of data on gas phase reaction rate constant and surface reaction constant was obtained.

  • PDF