• Title/Summary/Keyword: Monotonic load

Search Result 233, Processing Time 0.018 seconds

Flexural Strength Evaluation of Steel Plate-Concrete Composite Beam using Bolted (절곡 강판을 볼트로 체결한 강판-콘크리트 합성보의 휨강도 평가)

  • Han, Myoung-Hwan;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.126-136
    • /
    • 2018
  • A steel-plate concrete composite beam is composed of a steel plate, concrete and shear connector to combine inhomogeneous two materials. The steel plate is assembled by welding an existing composite beam. In this study, new steel-plate concrete composite beam, called a SPC Beam, was developed to reduce the shear connector and improve the workability. The SPC Beam was composed of folding steel plates and concrete, without a shear connector. The folding steel plate was assembled using high strength bolt instead of welding. To improve the workability in field construction, a hat-shaped Cap was attached to the junction with a slab. Monotonic load testing under two points was conducted under displacement control mode. The flexural strength of the specimen for positive moment and negative moment was calculated using the plastic stress distribution method. The test results showed that the flexural strength of the new SPC Beam had 80% of the strength of a complete composite beam. In addition, increasing the composite ratio was possible through clearance controls of the cap. In this study, the performance of the SPC Beam was verified through additional experiments and analyses with the cross-sectional shape and cap as variables, because the representative shape in the positive negative moment region is targeted.

Experimental Study for GFRP Reinforced Concrete Beams without Stirrups (스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2014
  • This paper evaluates the shear strength, behavior and failure mode of reinforced concrete beams with deformed GFRP reinforcing bar. Four concrete beam specimens were constructed and tested. It was carried out to observe failure behavior and load-deflection of simply supported concrete beams subjected to four-point monotonic loading. In order to eliminate of the uncertainty by the shear reinforcements, any stirrups were not used. Variables of the specimens were shear span-depth ratio, effective reinforcement ratio. The dimensions of specimen is 3,300 or $1,950mm{\times}200mm{\times}240mm$. Clear span and shear span were 2,900mm, 1,000mm respectively. Shear span-depth ratios were 6.5 and 2.5. Effective ratios of Longitudinal GFRP reinforcing bar were $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$ and $0.634{\rho}_{fb}$. All beam specimens were broken by diagonal-tension shear and the ACI 440.1R, CSA S806 and ISIS, which was used to design test beams, showed considerable deviation between prediction and test results of shear strengths.

Evaluation of Structural Performance of Reinforced Concrete Beams using Hybrid Retrofitting with Groove and Embedding FRP Rod and CFRP Sheet (표면요철 매입형 FRP봉과 CFRP시트를 복합 보강한 철근콘크리트 보의 구조성능 평가)

  • Ha, Gee-Joo;Ha, Young-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.41-49
    • /
    • 2014
  • In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam using hybrid retrofitting with two materials (groove and embedding FRP rod, CFRP sheet) in existing reinforced concrete buildings. Seven reinforced concrete beams, retrofitted groove and embedding FRP rod (NER series) and groove and embedding FRP rod with CFRP sheet (NERL series), and standard specimen (NBS) were constructed and tested under monotonic loading. Design parameters of test specimens are the amount of groove and embedding FRP rod and lapping CFRP sheet. Test results showed that the maximum load carrying capacity of specimens with groove and embedding FRP rod and groove and embedding FRP rod with CFRP sheet (NERL series) were increased the by 12~46% and 22~77% respectively in comparison with the standard specimen NBS. Test specimens NER series were failed with the adhesion slip and concrete cover separation. And test specimens NERL series were failed with the adhesion slip due to the confining effect of lapping CFRP sheet.