• Title/Summary/Keyword: Monotonic Load

Search Result 233, Processing Time 0.023 seconds

Hysteretic Behavior of RHS Columns Under Random Cyclic Loading Considering Local Buckling

  • Yamada, Satoshi;Ishida, Takanori;Jiao, Yu
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1761-1771
    • /
    • 2018
  • In this paper, a hysteretic model of rectangular hollow section (RHS) columns that includes the deteriorating range caused by local buckling is proposed. The proposed model consists of the skeleton curve, the Bauschinger part that appears before reaching the maximum strength, the strength increasing part of the deteriorating range, and the unloading part. Of these, the skeleton curve, including the deterioration range caused by local buckling, which is considered to be equivalent to the load-deformation relationship under monotonic loading, is obtained through an analytical method. Bi-linear hysteretic models based on experimental results are applied to the Bauschinger part and the strength increasing part. The elastic stiffness is applied to the unloading part. The proposed model is verified by comparing with experimental results of RHS columns under monotonic and cyclic loading.

Micro Computer Tomography Applied Monotonic Pullout Test for Deformed Rebar Bonding Model (이형 철근의 콘크리트 부착 모델 수립을 위한 Micro-CT 활용 단조가력 시험)

  • Jang, Indong;Cho, Junghyun;Yi, Chongku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.192-193
    • /
    • 2020
  • In reinforced concrete adhesion studies, the demolition of the specimen is inevitably involved, and the studies conducted are limited to the macro load-displacement analysis. In order to establish an elaborate model for concrete bonding reinforced rebars, it is necessary to observe the rebar bonding behavior in the in-situ state. In this study, specially manufactured reinforcing bars, micro-UTM and 𝝁-computer tomography (𝝁CT) are used to observe reinforcing bars in the in-situ state. As a result of the monotonic pullout test of the processed reinforcing bar, maximum bond stress were shown to be 16.7MPa, which is slightly higher than the existing 10 to 12 MPa, and then the empty space inside the specimen in which the pullout test was conducted using 𝝁CT was confirmed. Through additional research, the fracture phenomenon of concrete excluding voids will be studied.

  • PDF

A Study on the Cyclic Hardening Property and the Low Cycle Fatigue Behavior of Marine Materials (박용재료(舶用材料)의 반복경화(反復硬化) 및 저(低)싸이클 피로특성(疲勞特性)에 관한 연구)

  • S.M. Cho;K. Horikawa
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.108-116
    • /
    • 1991
  • In the non-linear behavior of many materials, there is difference between the monotonic behavior by static load and the cyclic behavior by cyclic load. In particular, the short fatigue cracks to propagate in elasto-plastic stress concentrations(notches), are governed significantly by the cyclic behavior of materials. Accordingly, it is needed to investigate and compare the monotonic and cyclic behavior of materials. In the pressent study, the stress-strain relations of materials by monotonic and cyclic load tests were examined for 2 kinds of steels(SS41, HT80) and 5 kinds of Al-alloys(A5083-O, A6N01-T5, A7N01-T4, A7016-T6, A7178-T6). And the constants for mechanical properties of the materials were determined by experimental results, Moreover, when a notch was subjected to cyclic load, the effect of cyclic hardening property of materials on the variation of stress-strain amplitude in the notch tip was discussed by the application of Neuber's rule and experiments for a center notched plate.

  • PDF

Load-Displacement Relationship of Passive Vibration Units Composed with a Spring and Vibration-Proof Rubbers (스프링과 방진고무가 융합된 제진장치의 하중-변위 관계)

  • Mun, Ju-Hyun;Im, Chae-Rim;Wang, Hye-Rin;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.226-234
    • /
    • 2021
  • The objective of this study is to establish the fundamental design data for axial load-displacement relationship under axial monotonic or cyclic responses of seismic damping·isolation (SDI) units developed for ceiling structures. The main parameters include the installation of a spring, the number of rubber layer, prestress stress of bolts for connector between the spring and rubbers, and loading type. Test results showed that SDI units with a spring in the core and higher prestress stress of bolts tended to be higher stiffness at the ascending branch and more ductile behavior at the descending branch. This trends more notable for the specimens under monotonic load rather than cyclic loads. Consequently, the energy dissipation of SDI unit can be optimally designed with the following conditions: installation of a spring within 3-layer rubbers and prestress applied to the bolts at 10% of their yielding strength . When compared with the experimental tension capacity of the developed SDI units, the predictions by JIS B 2704-1 and KDS 31 00 are conservative under monotonic loading but higher by approximately 10% under cyclic loading.

An Experimental Study on Failure Behavior of TP316 Stainless Steel Pipe with Local Wall Thinning and Cracking (국부 감육과 균열이 발생한 TP316 스테인리스강 배관의 파괴거동에 관한 실험적 연구)

  • Cheung, Jin Hwan;Kim, In Tae;Choi, Seock Jin;Choi, Hyung Suk;Kim, Hee Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.647-657
    • /
    • 2012
  • Although nuclear power plant piping system is designed conforming to design specifications, the piping systems are deteriorated with increase in service life. In this study, monotonic and cyclic loading tests were carried out on TP316 stainless steel pipe specimens, and the effect of local wall thinning and cracking on failure behavior was investigated. In the tests, 0%, 35% and 75% wall thinning and cracking of initial thickness were artificially introduced to inside elbow and straight pipe specimens, and internal pressures of 20MPa were applied to simulate real operation condition. From the test results, the effect of local wall thinning and cracking on failure mode, ultimate load, number of cycle and strain energy was presented, and maximum bending moment was compared with allowable bending moment calculated by ASME code.

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • v.32 no.4
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

Tensile Load Transmission Capacity of H-shaped Beam by Stud Connectors (스터드 커넥터로 연결된 H형강보의 인장하중 전달성능)

  • Lee, Myung Jae;Choi, Wan Chol;Kim, Won Ki;Kim, Jae Hee;Lee, Sang Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.267-274
    • /
    • 2004
  • The objective of this study is to evaluate tensile load transmission capacity of H-shaped beam about design load by stud connector. The basic test of stud connecter was conducted and two specimens of full-scale size were tested under monotonic tensile loading condition. The parameter of tests is the size of the H-shaped beams. The results show that tensile load transmission capacity of H-shape beam about design load by stud connectors is excellent observing to the design code of steel structures of Architectural Institute of Korea.

Performance Evaluation on Static Loading and Cyclic Loading for Structural Insulated Panels (구조용단열패널의 정적가력과 반복가력 성능 평가)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.

Investigation of the behavior of reinforced concrete hollow-core thick slabs

  • Al-Azzawi, Adel A.;Abed, Sadeq A.
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.567-577
    • /
    • 2017
  • This study presents investigation of the behavior of moderately thick reinforced concrete slabs having hollow cores with different parameters. The experimental part of this investigation includes testing eight specimens of solid and hollow-core slab models having (2.05 m) length, (0.6 m) width and (25 cm) thickness under two monotonic line loads. Load versus deflection was recorded during test at mid span and under load. Numerically, the finite element method is used to study the behavior of these reinforced concrete slabs by using ANSYS computer program. The specimens of slab models are modeled by using (SOLID65) element to represent concrete slabs and (LINK180) element to represent the steel bars as discrete axial members between concrete nodes. The finite element analysis has showed good agreement with the experimental results with difference of (4.71%-8.68%) in ultimate loads. A parametric study have been carried out by using ANSYS program to investigate the effects of concrete compressive strength, size and shape of core, type of applied load and effect of removing top steel reinforcement.

Effects of Load Ratio on Fatigue Crack Growth in a TMT Treated Al-Zn-Mg Alloy (가공열처리한 Al-Zn-Mg 합금의 피로균열 성장거동에 미치는 하중비의 영향)

  • Byun, E.S.;Kim, S.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.4
    • /
    • pp.19-26
    • /
    • 1989
  • Fundmental fatigue crack propagation tests with C-T type specimens were conducted at various load ratios (R) such as 0.1, 0.3 and 0.5 in T6 and Thermomechanically treated (TMT) conditions of 7039 Al alloy. Better mechanical properties from monotonic test as well as fatigue crack propagation were obtained by TMT process owing to uniform distribution of fine microstructures and non-existence of precipitation free zone (PFZ). Through the measurement of Kop and ${\Delta}K$ at various R the concept of effective stress intensity factor range ratio, U was reviewed to asses the load ratio effect on fatigue crack propagation. A relationship between U and variables such as ${\Delta}K$ and R was obtained empirically. This may enable us to predict ${\Delta}K_{eff}$ that is of critical importance for prediction of fatigue crack propagation rate.

  • PDF