• Title/Summary/Keyword: Monochromatic

Search Result 243, Processing Time 0.028 seconds

Distribution of Wave Forces at Points on a Vertical Structure of Semi-Infinite Breakwater Considering Diffraction (회절을 고려한 반무한방파제 형식의 직립구조물에 작용하는 지점별 파력 분포)

  • Jung, Jae-Sang;Lee, Changhoon;Cho, Yong-Sik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.4
    • /
    • pp.240-249
    • /
    • 2016
  • In this study, we investigated wave force distribution at points on a vertical structure of semi-infinite breakwater considering diffraction. Wave forces of monochromatic and random waves on a vertical structure are studied considering diffractions in front and lee side of the breakwater for non-breaking wave condition. We selected width of breakwater are 0 for reference condition. In monochromatic wave case, relative wave force becomes 0 on the head of the breakwater by acting incident wave force and diffracting wave force simultaneously and oscillating patterns of relative wave force occurs based on 1.0 as distance from the head increases. Relative wave force of monochromatic waves decreases as incident wave angle increases. Relative wave force of random waves is defined by using ratio of root mean square and wave force spectrum in this study. The case considering random phase of each wave components are compared to the case which don't consider random phase and both results are almost similar. Relative wave force of random waves is also 0 near the head of the breakwater likewise monochromatic wave. Oscillating pattern of relative wave force of random waves becomes relatively weaker for composition of each wave components as distance from the head increases.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Qualitative Analysis of Film Thickness in Elastohydrodynamic Lubrication (탄성 유체 윤활에서의 유막 두께 측정에 관한 정성적 분석)

  • 최언진;장시열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.147-155
    • /
    • 1999
  • The film thickness and shape of elastohydrodynamic lubrication is measured by optical interferometer, which is the most precise method for EHL film measurement. However the interpretation of the image pattern from optical viscometer is not easy for two-dimensional shape. A newly developed method of image processing makes it possible to evaluate the film thickness and shape in every point of contact region with two dimensional aspects. In this study, we captured film shape of EHL film from the monochromatic incident light with the Image processing method, which uses phase shift method, and obtained the image analysis method for gray level image in order to qualitatively evaluate film shapes.

  • PDF

Study on the Measurement Technology of Fluid Film Thickness with Nanometer Scale by Dichromatic Incident Light (Dichromatic 투사광선에 따른 나노 미터 해상도의 점접촉 유막 두께 측정 연구)

  • 공현상;장시열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.686-689
    • /
    • 2003
  • Many technologies are applied to the measurement of elastohydrodynamic lubrication (EHL) film thickness. In particular, optical in-situ interferometric method has many advantages in making the actual contact behaviors realized with the experimental apparatus. Careful selection of incident lights greatly enhances the fringe resolution up to nanometer scale by using image processing technology. In this work, it is found that dichromatic incident light can provide much finer resolution of EHL film thickness than monochromatic incident light, because it has much more variables of color components to be discriminated among the wavelengths of colors according the variations of EHL film thickness. Some simulated interferometric images are shown how the film thickness is resolutionized in nanometer scale

  • PDF

Subjective appraisal of the appearance on monochromatic light differenced by the eyeball's pigment

  • Muraoka, Tetsuya;Ikeda, Hiroaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1009-1013
    • /
    • 1990
  • In the Orient, most references are made on the visual perception of the eye having the blue iris, even in the case where the reference should be made on the perception by the eye having the dark iris. In order to clarify the difference in the visual perceptions of a monochromatic light, an objective boundary wavelength between hues incident on the dark eyes was obtained and the correlation between the valuesalready reported as having been obtained with the blue eyes was examined. A significant difference was found in the subjective boundary wavelengths of hues depending on the difference in the visual sensitivity distribution on the dark and blue eyes.

  • PDF

Photochromic Behavior and Its Stability of a New Bifunctional Dye Composed of Spirobenzopyran and a Cinnamoyl Moiety

  • Shen Kaihua;Kim Jae Hong;Kim Go Woon;Cho Min Ju;Lee Sang Kyu;Choi Dong Hoon
    • Macromolecular Research
    • /
    • v.13 no.3
    • /
    • pp.180-186
    • /
    • 2005
  • A novel bifunctional dye composed of spirobenzopyran and a cinnamoyl moiety was prepared and its photochromic behavior under the illumination of monochromatic UV light was investigated. This colorless bifunctional dye exhibits typical photochromism in both the film and in solution, through the structural and geometrical transformation from spirobenzopyran to merocyanine accompanied by a photocrosslinking reaction between the cinnamoyl moieties. Two kinds of photochemical reaction were selectively achieved by irradiation with monochromatic UV light at wavelengths of 275 and 365 nm, respectively. The effect of the selective photochemical reaction on the photochromism of the dye and its decaying behavior was investigated.

A Stereo-Vision System for 3D Position Recognition of Cow Teats on Robot Milking System (로봇 착유시스템의 3차원 유두위치인식을 위한 스테레오비젼 시스템)

  • Kim, Woong;Min, Byeong-Ro;Lee, Dea-Weon
    • Journal of Biosystems Engineering
    • /
    • v.32 no.1 s.120
    • /
    • pp.44-49
    • /
    • 2007
  • A stereo vision system was developed for robot milking system (RMS) using two monochromatic cameras. An algorithm for inverse perspective transformation was developed for the 3-D information acquisition of all teats. To verify performance of the algorithm in the stereo vision system, indoor tests were carried out using a test-board and model teats. A real cow and a model cow were used to measure distance errors. The maximum distance errors of test-board, model teats and real teats were 0.5 mm, 4.9 mm and 6 mm, respectively. The average distance errors of model teats and real teats were 2.9 mm and 4.43 mm, respectively. Therefore, it was concluded that this algorithm was sufficient for the RMS to be applied.

Measurement of Film Thickness by Fringe Intensity Analysis in Point Contact Elastohydrodynamic Lubrication (점접촉 탄성 유체 윤활에서의 띠 무의 강도에 의한 유막 두께 측정)

  • 장시열;최언진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.103-113
    • /
    • 1999
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by the image processing method for the monochromatic incident light. Interference between the reflected lights both on Cr coating of glass disk and on super finished ball makes circular fringes, which are regarded as film thickness together with numbering of fringe order. In this study, we developed technology to measure the film thickness by analyzing dark and bright intensity waves which results from monochrome green light. Two typical fringe patterns only with intensity values 3re examined for the measurement of point contact EHL film thickness. We expect that this technology will give valuable clue to improve color image processing analysis for high resolution of EHL film thickness with white incident light.

  • PDF