• 제목/요약/키워드: Monochromatic

검색결과 243건 처리시간 0.031초

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF

Monochromatic Image Analysis of Elastohydrodynamic Lubrication Film Thickness by Fringe Intensity Computation

  • Jang, Siyoul
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1704-1713
    • /
    • 2003
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by image processing method for the images from an optical interferometer with monochromatic incident light. Interference between the reflected lights both on half mirror Cr coating of glass disk and on super finished ball makes circular fringes depending on the contact conditions such as sliding velocity, applied load, viscosity-pressure characteristics and viscosity of lubricant under ambient pressure. In this situation the film thickness is regarded as the difference of optical paths between those reflected lights, which make dark and bright fringes with monochromatic incident light. The film thickness is computed by numbering the dark and bright fringe orders and the intensity (gray scale image) in each fringe regime is mapped to the corresponding film thickness. In this work, we developed a measuring technique for EHL film thickness by dividing the image patterns into two typical types under the condition of monochromatic incident light. During the image processing, the captured image is converted into digitally formatted data over the contact area without any loss of the image information of interferogram and it is also interpreted with consistency regardless of the observer's experimental experience. It is expected that the developed image processing method will provide a valuable basis to develop the image processing technique for color fringes, which is generally used for the measurement of relatively thin films in higher resolution.

Dental arch wires with tooth-like color

  • Chen, Sinn-Wen;Wu, Hsin-Jay;Liu, Chih-Hao;Chien, Yuan-Chun;Hu, Chih-Chang
    • Advances in materials Research
    • /
    • 제1권1호
    • /
    • pp.31-35
    • /
    • 2012
  • Unique tooth-like (milky white) color ${\beta}$-Ti dental arch wires are prepared by anodization in a 1M $H_2SO_4$ electrolyte at $30^{\circ}C$ and 30 V for 88 min and 40 s. Aggregates are formed on these surfaces of the anodized wires with tooth-like colors, and the results are different from those of the anodized wires with monochromatic colors which have smooth oxide surfaces. Similar to the monochromatic wires, the composition of the oxide layer is $TiO_{2-x}$ and the x approaches zero at the outer layer. But different from the amorphous structure observed in monochromatic wires, the oxide layers are partially crystallized with an anatase structure. The milky white colors result from the rough and crystalized oxide layers, not by the interference effect as observed in monochromatic wires.

A measurement of wave length response on light emitting diode by a simplified wavemeter with a semiconductor color sensor

  • Muraoka, Tetsuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1956-1960
    • /
    • 1991
  • This paper describes the measured results upon monochromatic light, compound light, and light emanated from light emitting diodes by a simplified wavemeter with a semiconductor color sensor. Since a single unit element of a semiconductor color sensor with two PN junction photodiodes has been developed, the author has fabricated the simplified wave detector by using the element. The simplified wive detector has been measured results upon monochromatic light, compound light, and light emanated from light emitting diodes. Since luminescent color of each diode locates in luminosity region, comparison of measured values of PD-150 and PD-151 resulted no remarkable difference in averaged wave length. As for monochromatic light, PD-151 showed very cross value to the color filter peak value rather than PD-150. As for compound light, PD-150 has shown such influence of long wave length light which reaches to near infrared ray with respect to PD-151.

  • PDF

COLORED PERMUTATIONS WITH NO MONOCHROMATIC CYCLES

  • Kim, Dongsu;Kim, Jang Soo;Seo, Seunghyun
    • 대한수학회지
    • /
    • 제54권4호
    • /
    • pp.1149-1161
    • /
    • 2017
  • An ($n_1,\;n_2,\;{\ldots},\;n_k$)-colored permutation is a permutation of $n_1+n_2+{\cdots}+n_k$ in which $1,\;2,\;{\ldots},\;n_1$ have color 1, and $n_1+1,\;n_1+2,\;{\ldots},\;n_1+n_2$ have color 2, and so on. We give a bijective proof of Steinhardt's result: the number of colored permutations with no monochromatic cycles is equal to the number of permutations with no fixed points after reordering the first $n_1$ elements, the next $n_2$ element, and so on, in ascending order. We then find the generating function for colored permutations with no monochromatic cycles. As an application we give a new proof of the well known generating function for colored permutations with no fixed colors, also known as multi-derangements.

미국인삼의 광합성에 미치는 단색광의 영향 (Photosynthesis Rate of American Ginseng under the different Monochromatic Light)

  • 이종철
    • Journal of Ginseng Research
    • /
    • 제12권1호
    • /
    • pp.87-91
    • /
    • 1988
  • 일복개량의 일환으로 일복의 피복재선택을 위한 기초자료를 얻고자 적색광, 청색광 및 백색광하에서 미국인삼(Panax quinquefolin L.)의 광합성을 측정하였다. 광질별 광합성량은 전반적으로 적색과, 백색광 및 청색광 순으로 많았으며 그 광합성량의 차이는 조도가 증가할수록 감소되었다. 따라서 일복의 피복물 색상은 적색으로 하는 것이 인삼(미국인삼) 생육에 유이할 것임을 시사되었다.

  • PDF

다층박막 거울을 이용한 단색 엑스선 획득 (Acquisition of Monochromatic X-ray Using Multilayer Mirror)

  • 천권수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.179-184
    • /
    • 2010
  • 나노 공간분해능을 갖는 영상을 얻기 위한 경엑스선 현미경 시스템에서는 단색 엑스선이 요구된다. 엑스선관에서 발생되는 화이트 빔으로부터 8.4 keV의 텅스텐 $L_{\alpha}$ 특성방사선을 84% 이상 반사시킬 수 있는 5.65 nm의 단위막 두께를 가지는 C/W 다층박막 거울을 설계하였고, 이온빔 스파터링 장치를 이용하여 $50{\times}50\;mm$ 크기로 제작하였다. 제작된 C/W 다층박막 거울은 99.5% 이상의 균일도(Uniformity)를 가지며, TEM 사진을 이용해 그 구조를 확인하였다. 8.05 keV의 구리 특성방사선을 광원으로 하는 엑스선 반사율 측정 장치를 이용한 다층박막 거울의 반사율을 측정함으로써 C/W 다층박막 거울의 8.4 keV에서의 반사율을 예상할 수 있었다. 제작된 C/W 다층박막 거울과 엑스선관을 이용하여 8.4 keV의 특성방사선을 획득함으로써 단색 엑스선을 획득하였다. 이때의 반사율은 77.1%였고, 단색 엑스선의 반치폭은 0.21 keV이었다. 엑스선관에서 높은 효율로 단색 엑스선을 획득할 수 있어 실험실 규모의 경엑스선 현미경 장치의 광원으로써 사용될 수 있는 가능성을 확인하였고, 다층박막 거울의 단위막 두께를 수 나노미터로 제작한다면 17.5 keV의 몰리브덴 특성방사선에 해당하는 단색 엑스선을 얻어 유방촬영에도 적용할 수 있을 것이다.

해안구조물 전면의 Stem Wave 특성에 관한 연구 (Effects of Stem Wave on the Vertical Breakwater)

  • 박효봉;윤한삼;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.138-143
    • /
    • 2001
  • Based on mild slope equation and parabolic approximation the forward diffraction of monochromatic waves by a straight breakwater are studied numerically. The characteristics and effects of stem wave along breakwater and the relations between the stem wave and incident wave angle are discussed.

  • PDF