• Title/Summary/Keyword: Monitoring well

Search Result 2,877, Processing Time 0.03 seconds

Occurrence Pattern of Intussusception according to the Introduction of Rotavirus Vaccine: An Observational Study at a University Hospital (로타바이러스 백신 도입에 따른 장겹침증 발생 경향: 한 대학병원 관찰 연구)

  • Nam, Hye Na;Lim, Kyung In;Tchah, Hann;Ryoo, Eell;Sun, Yong Han;Cho, Hye-Kyung
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.202-208
    • /
    • 2016
  • Purpose: Rotavirus vaccine (RV) was introduced in Korea since 2007, and intussusception (IS) remains an important safety concern. This study investigated the trend of IS occurrence related to RV as well as the temporal relevance between vaccination and IS in children. Methods: We collected data of the patient aged ${\leq}18$ years with IS admitted to Gachon University Gil Medical Center, 2003 to 2015. For the patients that have occurred since 2008, the immunization records of RV were collected. The proportion of cases <1 year was calculated by the year and the temporal relationship between vaccination and IS occurrence was analyzed. Results: A total of 696 IS cases were noted. The cases <1 year were 30.7% (214/696). Although the incidence of all IS has increased over the 13-year period (from 74.1 in 2003 to 89.5 in 2015, linear by linear association, P=0.003), the incidence of IS <1 year has not increased (from 56.9 in 2003 to 53.3 in 2015, P=0.910), and the proportion of cases <1 year has decreased (from 35.4 in 2003 to 18.8 in 2015, P=0.000). Of 128 cases <1 year since 2008, 53.9% received RV. In the vaccinated group, 10 cases of IS occurred within 30 days, and eight cases did within 31 to 60 days. Numbers of IS after first, second, and third dose were three, 10, and five cases, respectively. Conclusions: Occurrence of IS in children <1 year of age did not increase since the introduction of RV. Further monitoring is essential for evaluation of vaccine safety.

In Situ Surfactant Flushing of Contaminated Site (계면 활성제를 이용한 In Situ 토양 세척)

  • 염익태;안규홍
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.9-24
    • /
    • 1997
  • Surfactant-aided in situ soil flushing has been proposed as an alternative for the expensive and time consuming 'pump and treat' technology in remediation of contaminated soil and groundwater Injected surfactants can effectively solubilize contaminants sorbed to the soil matrix or nonaqueous phase liquids(NAPLs) in residual saturation. The contaminants solubilized in groundwater are recovered and treated further. The theoretical background of the technology and the results of the field operations, mostly in the US. were summarized. In addition, the factors crucial to the successful application of the technology were discussed. Cost analyses and technical limitations in current applications were also discussed. In conclusion, it is likely that in situ surfactant flushing become a viable option for soil remediation in limited cases. Currently, further advances with respect to operation cost and to treatment efficiency are required for more extensive application of the technology. However, the current trends in soil remediation, specially the growing emphasis on risk based corrective action and natural attenuation, will increase the competitiveness of the technology. For example, removal of easily washable contaminants by short term soil flushing followed by long term monitoring and natural attenuation can greatly reduce the operation cost and time.

  • PDF

The Monitoring of Heavy Metals in Human Bloods of Middle School Students (중학생의 혈액 중 중금속 모니터링)

  • Park Hee Ra;Kim Meehye;Kwun Ki-Sung;Kim Soon Ki;Heo Su-Jeong;Kim Kwang_Jin;Yum Tae-Kyung;Choi Kwang Sik;Kim Soo Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • This study was conducted to estimate the contents of heavy metals including lead, cadmium, zinc, copper as well as iron status(serum iron, total iron binding capacity, feritin etc)in blood samples of middle school students(n=300). The contents of heavy metals were determined using the GF-AAS (Graphite furnace Atomic Absorption Spectrophotometer). The microwave digestion method and dilution method were compared. The dilution method showed the better recovery and detection limit than microwave digestion method. The values of toxic metals in whloe blood of boys & girls were 3.46 & 3.05 for Pb,0.063 & 0.065 for Cd respectively (ug/dL). Also the values of trace metals in serum of boys & girls were 105.9 & 92.6 for Zn, 98.3 & 99.0 for Cu respectively (ug/dL). The prevalence of iron deficiency was $7.5\%$ in 146 boys and $14.3\%$ in 156 girls. The mean values of lead in girls were higher in iron deficiency, iron deficiency anemia and anemia groups than normal group. The mean values of lead and zinc were higher in boys compared to those in girls(P<0.05), the mean values of cadmium and copper in boys were similar to those in girls. Our results of toxic metals such as Pb & Cd showed lower to CDC's(Centers for Disease Control) blood lead levels of concern for children, 10 ug/dL.

An Evaluation of the Accuracy of Mini-Wright Peak Flowmeters in Patients with Asthma and Chronic Obstructive Pulmonary Disease (천식 및 만성폐쇄성폐질환 환자에서 Mini-Wright Peak Flowmeter로 측정한 최대호기유속의 정확도)

  • Choi, Won-Il;Han, Seung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.310-319
    • /
    • 2001
  • Background : The peak flowmeter is very useful in monitoring of out-patients as well as those in emergency departments because of its convenience and simplicity with low cost. There have been many studies aimed at determining the accuracy and reproducibility of the peak flow meter in normal population. However, there is a paucity of reports regarding its accuracy in patients with chronic obstructive pulmonary disease(COPD) or asthma. The accuracy of the peak expiratory flow(PEF) measured with a mini-Wright peak flowmeter was assessed by a comparison with the results of a mass flow sensor. Methods : The PEF measurements were performed in 108 patients aged 19-82 years presenting with either a chronic obstructive lung disease or asthma before and after inhaling salbutamol. The PEF measurements from the mini-Wright flowmeter were compared with those obtained by the calibrated mass flow sensor. Results : The average of the readings taken by the mini-Wright meter were 37-39 l/min higher than those taken by the mass flow sensor. The average percentage error of the mini-Wright meter were higher, ranging less than 300 l/min. The mean of the differences between the values obtained using both instruments (the bias)$\pm$limits of agreement(${\pm}2$ SD) were $37.1{\pm}90\;l/min$ for the PEF(p<0.001). Conclusions : The mini-Wright peak flowmeter overestimated the flows in patients with COPD or asthma. It was also found that the accuracy of the mini-Wright peak flowmeter decreased in its mid to low range. The limits of agreement are wide and the difference between the two instruments is significant. Therefore, the measurements made between the two types of machines in patients with asthma or COPD cannot be used interchangeably.

  • PDF

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

Study of the UAV for Application Plans and Landscape Analysis (UAV를 이용한 경관분석 및 활용방안에 관한 기초연구)

  • Kim, Seung-Min
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • This is the study to conduct the topographical analysis using the orthophotographic data from the waypoint flight using the UAV and constructed the system required for the automatic waypoint flight using the multicopter.. The results of the waypoint photographing are as follows. First, result of the waypoint flight over the area of 9.3ha, take time photogrammetry took 40 minutes in total. The multicopter have maintained the certain flight altitude and a constant speed that the accurate photographing was conducted over the waypoint determined by the ground station. Then, the effect of the photogrammetry was checked. Second, attached a digital camera to the multicopter which is lightweight and low in cost compared to the general photogrammetric unmanned airplane and then used it to check its mobility and economy. In addition, the matching of the photo data, and production of DEM and DXF files made it possible to analyze the topography. Third, produced the high resolution orthophoto(2cm) for the inside of the river and found out that the analysis is possible for the changes in vegetation and topography around the river. Fourth, It would be used for the more in-depth research on landscape analysis such as terrain analysis and visibility analysis. This method may be widely used to analyze the various terrains in cities and rivers. It can also be used for the landscape control such as cultural remains and tourist sites as well as the control of the cultural and historical resources such as the visibility analysis for the construction of DSM.

Development and Application of Multi-Functional Floating Wetland Island for Improving Water Quality (수질정화를 위한 다기능 인공식물섬의 개발과 적용)

  • Yoon, Younghan;Lim, Hyun Man;Kim, Weon Jae;Jung, Jin Hong;Park, Jae-Roh
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.221-230
    • /
    • 2016
  • Multi-functional floating wetland island (mFWI) was developed in order to prevent algal bloom and to improve water quality through several unit purification processes. A test bed was applied in the stagnant watershed in an urban area, from the summer to the winter season. For the advanced treatment, an artificial phosphorus adsorption/filtration medium was applied with micro-bubble generation, as well as water plants for nutrient removal. It appeared that the efficiency of chemical oxygen demand (COD) and total phosphorus (T-P) removal was higher in the warmer season (40.9%, 45.7%) than in the winter (15.9%, 20.0%), and the removal performance (suspended solid, chlorophyll a) in each process differs according to seasonal variation; micro-bubble performed better (33.1%, 39.2%) in the summer, and the P adsorption/filtration and water plants performed better (76.5%, 59.5%) in the winter season. From the results, it was understood that the mFWI performance was dependent upon the pollutant loads in different seasons and unit processes, and thus it requires continuous monitoring under various conditions to evaluate the functions. In addition, micro-bubbles helped prevent the formation of anaerobic zones in the lower part of the floating wetland. This resulted in the water circulation to form a new healthy aquatic ecosystem in the surrounding environment, which confirmed the positive influence of mFWI.

Proteinases and their Inhibitors in Cartilage and Synovial Fluid Acquired from a Canine Osteoarthritic Model (개 퇴행성 관절염 모델을 이용한 연골과 활액 내 단백질 분해 효소와 억제제의 작용 연구)

  • Seo, Jae-Won;Lee, Hae-Beom;Kim, Nam-Soo;Lee, Young-Hoon;Kang, Hyung-Sub;Kim, In-Shik;Park, Sang-Youel
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.144-149
    • /
    • 2009
  • Chondrocytes and synovial fluid derived markers are used to monitor for osteoarthritis(OA). Specific inhibitors, known as tissue inhibitors of metalloproteinases(TIMP), regulate the proteolytic activity of matrix metalloproteinases(MMP). This study investigated whether MMP and TIMP levels were altered in synovial fluid and cartilage following the experimental induction of OA in canines. Twenty mature beagle dogs underwent a unilateral surgical transection of the cranial cruciate ligament and the medial collateral ligament as well as a medial meniscectomy. Matrix metalloproteinase-2 and MMP-9 levels were assayed using Western blot and TIMP-2 levels were measured with enzyme-linked immunosorbent assays four weeks after OA induction. Increased MMP-2 expression was observed in chondrocytes isolated from cartilage following OA induction, but MMP-9 expression decreased. Matrix metalloproteinase-2 and MMP-9 levels in synovial fluid from the OA induced joint significantly increased compared to those of the sham group. Tissue inhibitors of metalloproteinase-2 concentrations were higher in chondrocytes from the OA cartilage, yet TIMP-2 remained lower in the synovial fluid of OA. This suggests the elevated release of MMP-9 over MMP-2 into the synovial fluid following the cartilage degradation-related death of chondrocytes after OA. Osteoarthritis can be further deteriorated by increased MMP activity in the synovial fluid because TIMP-2 exist low concentration into the extracellular matrix. As a result, MMP activity, particularly MMP-9 activity, can be useful as a biomarker in diagnosing and monitoring the early stages of canine OA.

Use of Antimicrobial Agents for the Treatment of Inpatients in Chonbuk National University Hospital (전북대학교병원 입원환자에서의 항생제 사용 실태)

  • Song, Jae Ho;Kim, Jung Soo
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.225-232
    • /
    • 2000
  • Purpose : The use antimicrobial agents is one of the important strategies for the treatment and prophylaxis of microbial infections. But injudicious abuse and misuse of antimicrobial agents is problem to add an extra weight on medical fee, increase of resistant bacteria and side effects according to the antibiotic use. This study was performed to establish the pertinent use of antimicrobial agent in Chonbuk National University Hospital(CNUH). Characteristics of antibiotics use was analysis by reviewing the medical records of patients admitted to CNUH during the period of May 1998. Methods : One thousand eight hundred and thirty three patients were enrolled in this study(medical division 1,014 cases, surgical division 819 cases). Medical records were retrospectively reviewed to classify the rate of antibiotics use, name of antibiotics used, appropriateness of antibiotics use. Results : The overall rate of antibiotic usage in CNUH was 67.2%(1,231/1,833), showing higher rate in surgical division(89.6%) compare to that of medical division(49.0%). Among 1,231 patients to whom antimicrobial agents were given, only 125(10.2%) were treated with single antimicrobial agents. 311(25.3%) were treated with two antimicrobial agents, and 795(64.5%) patients received 3 or more antibiotics. ${\beta}$-lactams(56.4%) were most frequently used followed by aminoglycosides(35.3%), the others(4.9%) and quinolons(3.4%). Amoxicillin-clavulanate was the mostly commonly used antibiotics followed by amoxicillin and unasyn. Prophylactic use of antibiotics was carried in seven hundred six patients(57.4%), mostly in surgical division, which can be considered somewhat inappropriate in the initiation time and duration of antibiotic use. Conclusion : Importance of monotherapy and appropriate prophylactic antibiotic use should be emphasized. Strategies of antibiotics use, such as restriction of drug use, continuous monitoring system, flow sheet system should be considered to reduce antibiotics use and establish the appropriate use of antibiotics as well as inhibiting the occurrence of resistant strains.

  • PDF