• Title/Summary/Keyword: Monitoring at a long distance

Search Result 54, Processing Time 0.024 seconds

The Use of Unmanned Aerial Vehicle for Monitoring Individuals of Ardeidae Species in Breeding Habitat: A Case study on Natural Monument in Sinjeop-ri, Yeoju, South Korea (백로류 집단번식지의 개체수 모니터링을 위한 무인항공기 활용연구 - 천연기념물 209호 여주 신접리 백로와 왜가리 번식지를 대상으로 -)

  • Park, Hyun-Chul;Kil, Sung-Ho;Seo, Ok-Ha
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.1
    • /
    • pp.73-84
    • /
    • 2019
  • In this research, it is a basic study to investigate the population of birds using UAVs. The research area is Ardeidae species(ASP) habitat and has long-term monitoring. The purpose of the study is to compare the ASP populations which analyzed ground observational survey and UAVs imagery. We used DJI's Mavic pro and Phantom4 for this research. Before investigating the population of ASP, we measured the escape distance by the UAVs, and the escape distances of the two UAVs models were statistically significant. Such a result would be different in UAV size and rotor(rotary wing) noise. The population of ASP who analyzed the ground observation and UAVs imagery count differed greatly. In detail, the population(mean) on the ground observation was 174.9, and the UAVs was 247.1 ~ 249.9. As a result of analyzing the UAVs imagery, These results indicate that the lower the UAVs camera altitude, the higher the ASP population, and the lower the UAVs camera altitude, the higher the resolution of the images and the better the reading of the individual of ASP. And we confirmed analyzed images taken at various altitudes, the individuals of ASP was not statistically significant. This is because the resolution of the phantom was superior to that of mavic pro. Our research is fundamental compared to similar studies. However, long-term monitoring for ASP of South Korea's by ground observation is a barrier of the reliability of the monitoring result. We suggested how to use UAVs which can improve long-term monitoring for ASP habitat.

Long Distance Identification of Water and Oil using an Ultraviolet Fluorescence Measurement System (원거리의 물과 오일을 구별할 수 있는 UV형광측정시스템 개발과 분석에 대한 연구)

  • Baek, Kyung-hoon;Lee, Joon-seok;Jeon, Su-jeong;Park, Bo-ram;Park, Seong-wook
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.266-270
    • /
    • 2022
  • Owing to the rising volume of seaborne trade, oil spills damage the marine environment for over 250 yearly. Thus, various analysis methods such as the Fourier-transform infrared (FTIR), Raman spectroscope, and gas chromatography are used to monitor oil spills at sea, but these methods are expensive. Recently, to reduce operational costs, an underwater fluorometer was adopted. However, this approach is not ideal for the remote sensing of oil spills because the device gets submerged in the sea. In this study, we have designed and developed a monitoring system that uses ultraviolet fluorescence to detect spilled oil or water from a distance, as well as proposed an analyzing method defining based on water Raman signal and QF535. Each fluorescence spectrum of water, oil (crude oil), and Bunker A was obtained using the system, and was calculated and analyzed from the spectrum individually. Based on the results of the analysis, we could successfully identity water and oil at a long distance.

Analysis and Simulation of SF6 Tracer Experiments for Tracking the Pollutant Transport (오염물질 이동 추적을 위한 SF6 추적자 실험 분석과 모사 연구)

  • 김영성;조성호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.397-410
    • /
    • 1998
  • Tracer experiments were performed 4 times in December 1992 on the relatively flat terrain and nearby building area adjacent to the Taedok Science Town in Korea. Each experiment was continued for relatively short period of 1 or 2 hours with intermittent release of SF6 up to 2.07g/s at 10m height. Movement of tracer plume was tracked by a continuous tracer analyzer installed on an air monitoring van. Simulation with INPUFF was carried out to analyze and predict experiments. Measured profiles of tracer plume were narrow and sharp while predicted profiles by INPUFF were broad and slowly varied. Tracer plumes were detected at a short distance of 0.5 to 2.2 km mainly due to intermittent release and high value of lower detectable limit. Various experimental conditions were tested by INPUFF simulation in order to find desirable conditions. Higher wind speed and less variable wind direction could yield longer distance of plume tracking only when the lower detectable limit was sufficiently low. Distance of plume tracking was long and did not much depend on the lower detectable limit in stable atmospheric conditions.

  • PDF

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

A Study of Development of a Remote Monitoring Data Acquisition System using TCP/IP Protocol (TCP/IP Protocol을 이용한 원격 감시용 계측 시스템 개발에 관한 연구)

  • 문경록;이주열;김재문
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.173-176
    • /
    • 2002
  • DAS(Data Acquisition System) as a ground support equipment has played a critical role in proving the status of ready-to-fire of a rocket system before launch. But it is hard to implement and place a real-time measuring system in a control room at a long distance from the vehicle. In this paper DAS is introduced by being located at the LEC(Launch Equipment Container)[1], 50 meters away from the rocket and connected to remote monitoring system via fiber optics with TCP/IP protocol by means of client/server algorithm. Therefore real-time data acquisition and storage are guaranteed and a convenient and useful MMI (Man-Machine Interface) can be developed.

  • PDF

A Real Time Monitoring for Water Quality of River (수질자동모니터링시스템의 설치 현황과 전망)

  • Ryu, Jae-Kuen
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.

Development of n Remote Monitoring System for TFT-LCD Panel Test Automation (TFT-LCD 채널검사 자동화를 위한 원격 모니터링 시스템 개발)

  • Park, Hyoung-Keun;Lee, Seung-Dae;Kim, Sun-Youb
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.483-487
    • /
    • 2007
  • In this study, we develop a new remote monitoring system for TFT-LCD panel test automation. Having to realtime monitor of Ti-Con board, this system needs to discrimination whether breakdown or not that is able to transmit processing data for engineer at long distance place using TCP/IP. The result of the development, that can be fast opposition to the breakdown and the multiple processing

  • PDF

Implementation of the 3 axes Attitude Control Sensor System (3축 자세 제어용 센서 시스템의 구현)

  • Jeong, Jong-Won;Choi, Woo-Jin;Ji, Suk-Jun;Lee, Ki-Young;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2329-2331
    • /
    • 2001
  • In this paper, were developed the 3 axes attitude control sensor system to control and monitoring the moving object. The proposed sensor system has been studied in Japan, America for a year ago. But it is high expensive and has a difficulty in application. To overcome these problems, proposed the 3 axes attitude control sensor system is low cost and easily applied. Proposed sensor system is equipped with the 3 gyro sensors, 2 tilt sensors and 3 MR sensors using 80C51 microprocessor for signal processing. It's output value transmit at long distance using RS232 serial communication protocol. We expect this system shall have a good performances in many applications of control and monitoring the moving object.

  • PDF

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Regional Image Noise Analysis for Steel-tube X-ray Image (강판튜브 엑스선 영상의 영역별 영상잡음 특성분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.32-34
    • /
    • 2007
  • The X-ray projection system has long been used for steel-tube inspection and weld monitoring. The thickness of tubes and welded areas is based on the evaluation of radiographic shadow projections. The traditional tangential measurement estimates the distance of border lines of the projected wall shadows of a tube onto a radiographic image detector. The detected image in which although there is a variety of noise may be sectioned into several partitions according to its specific blocks. Imaging noise originates from most of elements of the system, such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc. The tangential projection incorrectness and noise influence on imaging quality. In this paper we first sectionalize the X-ray image on the basis of vertical contrast difference. And next functional and statistic analysis are carried on at each region. Geometrical distance and unsharpness of the edge caused by visual evaluation uncertainties are also discussed.

  • PDF