• Title/Summary/Keyword: Monitoring Guideline

Search Result 241, Processing Time 0.023 seconds

Two-stage damage identification for bridge bearings based on sailfish optimization and element relative modal strain energy

  • Minshui Huang;Zhongzheng Ling;Chang Sun;Yongzhi Lei;Chunyan Xiang;Zihao Wan;Jianfeng Gu
    • Structural Engineering and Mechanics
    • /
    • v.86 no.6
    • /
    • pp.715-730
    • /
    • 2023
  • Broad studies have addressed the issue of structural element damage identification, however, rubber bearing, as a key component of load transmission between the superstructure and substructure, is essential to the operational safety of a bridge, which should be paid more attention to its health condition. However, regarding the limitations of the traditional bearing damage detection methods as well as few studies have been conducted on this topic, in this paper, inspired by the model updating-based structural damage identification, a two-stage bearing damage identification method has been proposed. In the first stage, we deduce a novel bearing damage localization indicator, called element relative MSE, to accurately determine the bearing damage location. In the second one, the prior knowledge of bearing damage localization is combined with sailfish optimization (SFO) to perform the bearing damage estimation. In order to validate the feasibility, a numerical example of a 5-span continuous beam is introduced, also the noise robustness has been investigated. Meanwhile, the effectiveness and engineering applicability are further verified based on an experimental simply supported beam and actual engineering of the I-40 Bridge. The obtained results are good, which indicate that the proposed method is not only suitable for simple structures but also can accurately locate the bearing damage site and identify its severity for complex structure. To summarize, the proposed method provides a good guideline for the issue of bridge bearing detection, which could be used to reduce the difficulty of the traditional bearing failure detection approach, further saving labor costs and economic expenses.

Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET (EPANET을 이용한 상수도 관망의 잔류염소 거동 예측)

  • 유희종;김주원;정효준;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.

Switch to Olanzapine from Clozapine or Risperidone and 12-months Follow Up (Clozapine과 Risperidone에서 Olanzapine으로 교체 연구 : 12개월 추적연구)

  • Cho, Bang Hyun;Jung, In Kwa;Paik, Jong Woo
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.140-146
    • /
    • 2001
  • In clinical setting, treatment-refractoriness, medication induced tardive dyskinesia and amenorrhea in chronic schizophrenia are frequently problematic. However, there are few guideline solving these problem available to clinicians. The goal of this study was collecting clinical data on clinical effectiveness and predictors of response of switching to olanzapine. We attempted to switch to olanzapine from risperidone and clozapine in chronic 31(risperidone 17, clozapine 14) schizophrenia and schizoaffective disorder patients suffering from sustained symptoms, weekly blood monitoring, medication induced tardive dyskinesia and amenorrhea. Previous antipsychotics dosage was gradually decreased for 2 or 3weeks, at the same time olanzapine dosage was gradually increased. At baseline, after 1 week, after 2 weeks and after 4 weeks we checked Brief Psychiatric Rating Scale, Clinical Global Impression Scale, Sympson-Angus Rating Scale, Barnes Akathisia Rating Scale and followed up after 12 months. Successful switch after 4 weeks was achieved in 25 patients(clozapine 9(64.2%), risperidone 16(94.1%)). Overall, mean BPRS and CGI scores increased significantly. Successful maintenance after 12 months was achieved in 17 patients(clozapine 5(35.7%), risperidone 12(70.5%)). Overall, mean BPRS and CGI scores increased significantly too. Switching to olanzapine from other atypical antipsychotics is recommendable in chronic schizophrenia with treatment refractoriness and drug induced side effect.

  • PDF

Technical Status of Confined Disposal Facilities for Dredged Materials (준설토 처리를 위한 해상처분장 기술 현황)

  • Oh, Myoung-Hak;Yoon, Gil-Lim;Oh, Young-Min
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.383-385
    • /
    • 2012
  • Confined Disposal Facilities(CDF) are an effective and commonly used management option for contaminated dredged material. CDF is an engineered contstruction for containment of contaminated dredged material to control potential releases to the environment. Although the concept is simple, constructing a CDF is a complex and non-standard process. In the process of planning a CDF, many different fields of expertise have to be considered, such as civil engineering, landscaping, chemistry, legislation, social impact, and environmental engineering. This paper provides the concise overview of common guidance on CDF.

  • PDF

The Preventing and Diagnosis of Ultra High Voltage Substation Devices and Combination with An Automation System of A Substation (초고압 변전기기의 예방진단 및 종합 자동화)

  • Yang, Hang-Jun;Kim, Kyung-Geun;Kim, Sung-Sik;You, Jeong-Sik;Kim, Hong-Suk;Lee, Hahk-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.275-277
    • /
    • 2001
  • In this paper a preventative and diagnostic system for high and ultra high voltage electric power transmission apparatus is proposed to secure substation normal operation. The proposed system consists of monitoring sub-system and diagnostic sub-system, which are mainly for GIS and main transformer, and the system will be applied for newly established 765kV class substation in Korea. Some guideline for combination with substation control system are presented, and engineering solution as an improved substation automation system is also proposed.

  • PDF

Hydrochemical Characteristics and Changes by Rainfall in the Jungrang River (강우에 의한 중랑천의 수질 특성 변화 연구)

  • Kim, Youn-Tae;Kim, Yu Lee;Woo, Nam-Chil;Hyun, Seung Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.666-671
    • /
    • 2006
  • Effects of a rainfall event (July 28, 2005) on the hydrochemical characteristics of the Jungrang river, the biggest tributary of the Han river, was investigated. Significant spatial variations in the hydrochemical characteristics were observed. At JR2 location, concentrations of T-N and T-P were relatively low indicating occurrence of active oxidation in the stepped drop structure. At JR3 location, concentrations of Na, K, Cl, $NH_4-N$ and EC were elevated suggesting increased discharge from the nearby waste-water treatment plant and tributaries. The rain event diluted major dissolved ion concentrations in the river by 12~52%. The $NO_3-N$ levels were preserved during the rain then increased about twofold after rainfall, suggesting increased discharge of nitrate-contaminated groundwater. Heavy metals including Cd, Co, Cr, Cu and Pb were not detected in all water samples and the leachates from surface sediment samples. Concentrations of Fe, Mn, Al and Zn were below the Korean Drinking Water Guideline. Results of this study suggested that establishment of water-quality monitoring protocols describing temporal and spatial variations in parameters sensitive to rainfall events, relatively steady factors, and contaminant sources is required.

Development of 3MW Wind Turbine for IEC Wind Class IIa (3MW급 IEC Wind Class IIa 풍력발전시스템 개발)

  • Lee, K.H.;Lee, S.I.;Woo, S.W.;Oh, I.G.;Park, J.P.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.236-239
    • /
    • 2011
  • This paper introduces the design concepts and characteristics of WinDS3000$^{TM}$(TC IIa) which is a trade name of Doosan's 3MW offshore/onshore wind turbine. WinDS3000$^{TM}$(TC IIa) has been designed in consideration of high Reliability, Availability, Maintainability and Serviceability (RAMS) and low cost of electricity (CDE) for the TC IIa condition based on GL guideline. An integrated drive-train design with an innovative three-stage gearbox has been introduced to minimize nacelle weight of the wind turbine and to enhance a high reliability for transmission. A permanent magnet generator with full converter system has been introduced to get higher efficiency in partial load operation and grid-friendly system for both 50 Hz and 60 Hz. A pitch-regulated variable speed control system has been introduced to control wind turbine power while generator reaction torque can be adjusted almost instantaneously by the associated power electronics. The wind turbine has been also equipped with condition monitoring and diagnostic systems in order to meet maintainability requirements.

  • PDF

Guidelines for the Establishment and Vitalization Scheme on Facility of Nature Environmental Conservation and its Utilization (자연환경보전·이용시설 가이드라인 및 활성화방안)

  • Choi, Jaeyong;Park, Sohyun;Lee, Dong Kun;Shin, Kyungjoon;Hong, Taesik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.4
    • /
    • pp.36-51
    • /
    • 2006
  • Although the demand and necessity for the facilities of nature environmental conservation and its utilization have been increased recently, the local governments has been experiencing difficulties to launch the facilities since there are no confirmed principles or guidelines for the direction of the facility and distinctions from the ordinary parks. In this regard, the aim of this paper is to provide the overall framework for establishing the facility by equipping checklists from planning to operational stage. The stages are disengaged into 5 steps of siting feasibility, planning, preliminary environmental assessment and environmental impact assessment, design, construction, and operation. This paper also include the recommendations to vitalize the existing facilities, of which expansion of educational program development; utilization of various manpower; provision of appropriate settings; strengthened monitoring; and increased public relations. Furthermore, it is suggested to consider the strengthened local characteristics, reviewing management plan at the stage of applying a new facility establishment to the concerned authority, fostering experts, and expansion of the facilities through restoration of environmentally damaged areas for a new facility.

Cardiopulmonary Resuscitation: New Concept

  • Lee, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • Cardiopulmonary resuscitation (CPR) is a series of life-saving actions that improve the chances of survival, following cardiac arrest. Successful resuscitation, following cardiac arrest, requires an integrated set of coordinated actions represented by the links in the Chain of Survival. The links include the following: immediate recognition of cardiac arrest and activation of the emergency response system, early CPR with an emphasis on chest compressions, rapid defibrillation, effective advanced life support, and integrated post-cardiac arrest care. The newest development in the CPR guideline is a change in the basic life support sequence of steps from "A-B-C" (Airway, Breathing, Chest compressions) to "C-A-B" (Chest compressions, Airway, Breathing) for adults. Also, "Hands-Only (compression only) CPR" is emphasized for the untrained lay rescuer. On the basis of the strength of the available evidence, there was unanimous support for continuous emphasis on high-quality CPR with compressions of adequate rate and depth, which allows for complete chest recoil, minimizing interruptions in chest compressions and avoiding excessive ventilation. High-quality CPR is the cornerstone of a system of care that can optimize outcomes beyond return of spontaneous circulation (ROSC). There is an increased emphasis on physiologic monitoring to optimize CPR quality, and to detect ROSC. A comprehensive, structured, integrated, multidisciplinary system of care should be implemented in a consistent manner for the treatment of post-cardiac arrest care patients. The return to a prior quality and functional state of health is the ultimate goal of a resuscitation system of care.

The measured contribution of whipping and springing on the fatigue and extreme loading of container vessels

  • Storhaug, Gaute
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.1096-1110
    • /
    • 2014
  • Whipping/springing research started in the 50'ies. In the 60'ies inland water vessels design rules became stricter due to whipping/springing. The research during the 70-90'ies may be regarded as academic. In 2000 a large ore carrier was strengthened due to severe cracking from North Atlantic operation, and whipping/springing contributed to half of the fatigue damage. Measurement campaigns on blunt and slender vessels were initiated. A few blunt ships were designed to account for whipping/springing. Based on the measurements, the focus shifted from fatigue to extreme loading. In 2005 model tests of a 4,400 TEU container vessel included extreme whipping scenarios. In 2007 the 4400 TEU vessel MSC Napoli broke in two under similar conditions. In 2009 model tests of an 8,600 TEU container vessel container vessel included extreme whipping scenarios. In 2013 the 8,100 TEU vessel MOL COMFORT broke in two under similar conditions. Several classification societies have published voluntary guidelines, which have been used to include whipping/springing in the design of several container vessels. This paper covers results from model tests and full scale measurements used as background for the DNV Legacy guideline. Uncertainties are discussed and recommendations are given in order to obtain useful data. Whipping/springing is no longer academic.