• Title/Summary/Keyword: Monitoring Evaluation

검색결과 2,572건 처리시간 0.029초

수중 방사선 감시체계 구축을 위한 실시간 방사선 준위 모니터링 센서 개발 (Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System)

  • 박혜민;주관식
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.96-100
    • /
    • 2015
  • In the present study, we developed a real-time radiation-monitoring sensor for an underwater radiation-monitoring system and evaluated its effectiveness using reference radiation sources. The monitoring sensor was designed and miniaturized using a silicon photomultiplier (SiPM) and a cerium-doped-gadolinium-aluminum-gallium-garnet (Ce:GAGG) scintillator, and an underwater wireless monitoring system was implemented by employing a remote Bluetooth communication module. An acrylic water tank and reference radiation sources ($^{137}Cs$, $^{90}Sr$) were used to evaluate the effectiveness of the monitoring sensor. The underwater monitoring sensor's detection response and efficiency for gamma rays and beta particles as well as the linearity of the response according to the gammaray intensity were verified through an evaluation. This evaluation is expected to contribute to the development of base technology for an underwater radiation-monitoring system.

P.C. BOX 교량의 재하시험 및 원격계측 유지관리 시스템 (Load Test and Remote Monitoring of P.C. Box Girder Bridge)

  • Lee, Sung-Woo;Doobyong Bae;Lee, Sun-Goo
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.122-131
    • /
    • 1995
  • Load test for newly introduced precast segmental bridge is carried out to experimentally evaluate load carrying capacity, Analysis accompanied with the test is also performed and the results are used in the evaluation. In addition to initial evaluation of the bridge by load test, remote dynamic monitoring system to perform realtime assessment of the bridge condition is also under development. In this paper the procedure and results of load test and evaluation are presented along with introduction of dynamic monitoring system.

  • PDF

선도기술개발사업 1단계 평가사례 연구

  • 임윤철;이철원
    • 기술경영경제학회:학술대회논문집
    • /
    • 기술경영경제학회 1997년도 제11회 하계학술발표회 논문집
    • /
    • pp.266-285
    • /
    • 1997
  • This paper addresses a methodology for monitoring the first phase('92-'94) progress and its strategic implication of Highly Advanced National R&D Program(HAN or G7 project) in Korea. The conceptual framework and its strategic thrust of the interim evaluation, which is the main focus of this paper, was designed both by reviewing related literature and by analyzing the unique characteristics of the HAN Program. Actual monitoring or interim evaluation was initiated by the G7 Planning and Evaluation Committee, which was established for advising, directing, and monitoring the HAN Program, with the help of large number of experts from various industries, universities, and research institutes. The monitoring results had been reported to the related ministries and project coordinating agencies. According to the suggestion made by the G7 Planning and Evaluation Committee, several projects were suffered structural changes and one was dropped.

  • PDF

The application of a fuzzy inference system and analytical hierarchy process based online evaluation framework to the Donghai Bridge Health Monitoring System

  • Dan, Danhui;Sun, Limin;Yang, Zhifang;Xie, Daqi
    • Smart Structures and Systems
    • /
    • 제14권2호
    • /
    • pp.129-144
    • /
    • 2014
  • In this paper, a fuzzy inference system and an analytical hierarchy process-based online evaluation technique is developed to monitor the condition of the 32-km Donghai Bridge in Shanghai. The system has 478 sensors distributed along eight segments selected from the whole bridge. An online evaluation subsystem is realized, which uses raw data and extracted features or indices to give a set of hierarchically organized condition evaluations. The thresholds of each index were set to an initial value obtained from a structure damage and performance evolution analysis of the bridge. After one year of baseline monitoring, the initial threshold system was updated from the collected data. The results show that the techniques described are valid and reliable. The online method fulfills long-term infrastructure health monitoring requirements for the Donghai Bridge.

750kW 풍력발전기의 소음실증 (Noise Test and Evaluation of a 750kW Wind Turbine Generator)

  • 김석현;허욱;이현우
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

Structural performance monitoring of an urban footbridge

  • Xi, P.S.;Ye, X.W.;Jin, T.;Chen, B.
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.129-150
    • /
    • 2018
  • This paper presents the structural performance monitoring of an urban footbridge located in Hangzhou, China. The structural health monitoring (SHM) system is designed and implemented for the footbridge to monitor the structural responses of the footbridge and to ensure the structural safety during the period of operation. The monitoring data of stress and displacement measured by the fiber Bragg grating (FBG)-based sensors installed at the critical locations are used to analyze and assess the operation performance of the footbridge. A linear regression method is applied to separate the temperature effect from the stress monitoring data measured by the FBG-based strain sensors. In addition, the static vertical displacement of the footbridge measured by the FBG-based hydrostatic level gauges are presented and compared with the dynamic displacement remotely measured by a machine vision-based measurement system. Based on the examination of the monitored stress and displacement data, the structural safety evaluation is executed in combination with the defined condition index.

녹화영상 활용 학습법이 학생들의 '환자-의사관계'에서의 자기성찰에 미치는 영향 (The Effect of Recorded Video Monitoring on Students' Self Reflection of Patient-Physician Interaction)

  • 주미선;황지영;김재명;강재구
    • 의학교육논단
    • /
    • 제19권2호
    • /
    • pp.83-89
    • /
    • 2017
  • The aim of this study is to examine the effect of recorded video monitoring on students' self-reflection after completing their clinical performance examination. Taking into account the particular cases involved in the examination, the present study utilized history-taking, physical examination, and patient education as bases for evaluating information-establishment ability, and asking, listening, understanding, explaining, and connectedness as the bases for evaluating patient-physician interaction ability. Student self-monitoring through recorded video feedback was carried out three days after completion of their clinical performance examination. Students self-evaluated their performance with a 10-point scale before and after self-monitoring. The results of this study show that students have a general tendency to lower their own self-evaluation scores after self-monitoring. Although there was not a statistically significant change of interrelationship in the information-establishment ability evaluation, there was a meaningful change of interrelationship in the patient-physician interaction ability evaluation after self-monitoring; specifically, in the case of acute lower abdominal pain, a high correlation was found (r=0.31, p=0.02) between the evaluation scores of standardized patients and students related to patient-physician interaction ability. This implies that self-monitoring enables the students to acquire a reflective viewpoint from which to evaluate their own performance. Therefore, it can be said that self-monitoring through recorded video feedback is a valuable method for students to use in reviewing their performance in patient-physician interactions.

풍력발전기 소음 성능 실증 (Noise Performance Test and Evaluation of a Wind Turbing Generator)

  • 김석현;김태형;박무열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

필댐 안전관리를 위한 계측기 중요도의 평가기법 (Evaluation Technique of Importance of Monitoring Systems for Earth and Rockfill Dam Safety)

  • 이종욱;김재홍;오병현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.874-882
    • /
    • 2009
  • Continuous monitoring of dam performance is essential to earth and rockfill dams safety because it has to be guaranteed for safety during construction period of course and from initial impounding to a long term maintenance period of dam. Among the 31 dams managed by Kwater at present, the proportion of dams being over 20 years after completion of construction is 42% and it is estimated that the loss rate of monitoring devices will be increase as times. Monitoring devices would be impossible to repair since those are mostly installed in the dam body and foundation. If repairing of monitoring devices is possible, the expenditure will be expensive. Therefore reasonable decision making for abandonment, repair and alternation for loss of monitoring devices would be needed through the establishment of key instrument for earth and rockfill dam safety. In this study the process of monitoring for safety were modeled by failure modes of dams, adverse conditions related to failure mode, indicators of adverse condition and monitoring devices The relationship between failure mode and monitoring devices were systematically analyzed and established and evaluation technique for qualifying the importance of monitoring devices were presented.

  • PDF

RAMS evaluation for a steel-truss arch high-speed railway bridge based on SHM system

  • Zhao, Han-Wei;Ding, You-Liang;Geng, Fang-Fang;Li, Ai-Qun
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.79-92
    • /
    • 2018
  • The evaluation theory of reliability, availability, maintainability and safety (RAMS) as a mature theory of state evaluation in the railway engineering, can be well used to the evaluation, management, and maintenance of complicated structure like the long-span bridge structures on the high-speed railway. Taking a typical steel-truss arch bridge on the Beijing-Shanghai high-speed railway, the Nanjing Dashengguan Yangtze River Bridge, this paper developed a new method of state evaluation for the existing steel-truss arch high-speed railway bridge. The evaluation framework of serving state for the bridge structure is presented based on the RAMS theory. According to the failure-risk, safety/availability, maintenance of bridge members, the state evaluation method of each monitoring item is presented. The weights of the performance items and the monitoring items in all evaluation levels are obtained using the analytic hierarchy process. Finally, the comprehensive serving state of bridge structure is hierarchical evaluated.