• 제목/요약/키워드: Monitor Unit (MU)

검색결과 42건 처리시간 0.032초

Excell 프로그램을 통한 치료선량(M. U) 계산 (Monitor Unit calculation through Excell program)

  • 임광채;조은주;조선행
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.28-32
    • /
    • 1999
  • Verifying the treatment value(Monitor Unit) unnecessarily involves too many simple and repetitive calculation processes, that is, individual computation process using the data(PDD value, Scp Factor, SSD Factor, Tray Factor) on the data book. We intend to minimize the time required to check the Monitor Unit through computerized calculation. Using $^{\ast}(multiplication)$, /(division), +(sum), if function, among others, which are present in the Excell program, MS office program, the Monitor Unit was obtainable through A/P value, Scp Factor and PDD value, Wedge Factor. From the verification of the computations of Monitor Unit for 60 patients previously treated, we were able to obtain an error rate of ${\pm}0.028MU$. Computerized calculation of the Monitor Unit could save the burden of Technologist.

  • PDF

다이오드 어레이를 이용한 Siemens사의 Primus 선형가속기의 저 MU 특성 분석 (Analysis of Low MU Characteristics of Siemens Primus Linear Accelerator using Diode Arrays for IMRT QA)

  • 김주리;이레나;이경자
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.164-171
    • /
    • 2008
  • 세기조절방사선치료를 임상에 도입하는데 있어서 가장 중요한 관건 중 하나는 총 부여선량(monitor unit, MU)이 작을 경우에 조사량을 측정하는 방법이다. 따라서 본 연구에서는 다이오드 어레이를 사용하여 방사선량의 선형도, 선량 평탄도와 대칭도, 다엽조리개 위치 정확도 등을 점검할수 있는 방법에 대해 연구하였다. 6 MV와 10 MV, 2가지의 방사선이 조사되는 Simens Primus 선형가속기에서 멀티 다이오드 어레이를 사용하여 측정하였다. 총 부여선량의 안정도는 2가지 에너지에서 모두 측정되었다. 6 MV 에너지에서 선량의 선형도 오차는 20 MU, 10 MU, 5 MU, 4 MU, 2 MU 조사 시 각각 2.1, 3.4, 6.9, 8.6, 15.4%이었다. 10 MV 에너지 경우는 선량의 선형적 오차가 더 커서 2 MU 조사 시 최대 오차는 22%였다. 이러한 오차들은 D1_C0 값을 조절하여 교정하였을 경우는 모든 측정 값에서 2% 이내로 감소하였다. 선량 편평도와 대칭도는 교정 없이도 허용오차 범위에 포함되었다. 다이오드 배열장치를 사용하거나, 필름 측정을 이용하여 측정한 경우 picket fence test 값은 비슷한 결과를 나타내었다. 다이오드 어레이는 세기조절 방사선 치료시 방사선 안정도, 대칭도, 편평도, 및 다엽조리개의 위치정확도를 검사할 때 편한 방법이다. 또한 Siemens 선형가속기는 일반적인 D1-C0값이 0으로 되어 있는데, 강도조절 방사선치료를 사용할 때는 D1-C0값을 총 부여선량이 20이하일 때 방사선의 안정도가 큰 오차를 보이므로 반드시 D1_C0값을 조절하여 교정해야 한다.

  • PDF

다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구 (A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field)

  • 김주호;이상규;신현경;이석;나수경;조정희;김동욱
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.155-160
    • /
    • 2005
  • 목 적 : 전산화단층 모의치료조준(CT simulation)과 선량 계획 장비(RTP)의 발전으로 많은 저자들에 의해 종양부 위의 선량을 증가시키고 인접한 장기의 선량을 효과적으로 감소시킬 수 있는 3차원 입체 조형 치료(Conformal therapy)와 조사면내 선량 보강 기법(Field in field technique)이 자주 소개되어지고 있다. 이러한 치료 기법은 많은 수의 조사면을 사용함으로써 조사면이 증가할수록 10 MU이하의 극히 적은 기계적 입력치(monitor unit, MU)를 사용하기도 한다. 통상 일반적으로 사용되어지는 선량에 대한 정보(beam data)는 이보다 훨씬 많은 100 MU이상 혹은 그보다 높은 안정적인 출력을 기대할 수 있는 상태에서 측정되어지므로 극히 적은 기계적 입력치에서도 기존에 측정되어진 선량 정보와 동일한 선량분포를 구현할 수 있는지 반드시 확인하여야 한다. 따라서 본 연구에서는 극히 적은 기계적 입력치(MU)에서의 선량적 안정성을 알아보고 향후 정도 관리지침에 활용코자 한다. 대상 및 방법 : 본원에서 사용 중인 선형가속기 Varian 2100C/D의 6 MV, 10 MV(USA)와 Varinan 600C의 4 MV(USA)의 에너지를 사용하여 $10{\times}10cm^2$ 조사면에서 90 MU를 90 MU, 45 MU, 30 MU, 18 MU, 9 MU, 6 MU로 각각 1, 2, 3, 5, 10, 15 회씩 나누어 조사하였다. 전리함(pinpoint farmer type chamber, PTW, GERMANY)를 이용하며 4 MV, 6 MV는 5 cm, 10 MV는 10 cm 깊이, SAD 100 cm에서 물 팬텀을 이용하며 조사면내의 출력을 측정하였고, 측정용 필름(X-omat V, Kodak, USA)을 이용하며 높은 선량을 나타내는 90 MU, 30 MU에서의 편평도와, 대칭도를 비교하였고 일반적인 medical film(AGFA USA)을 이용하여 낮은 선량을 보이는 9MU에서 조사면내 편평도와, 대칭도를 비교하여 선질의 특성 변화를 관찰하였다. 결 과 : 전리함을 이용한 측정에서 2100C/D는 90 MU와 9 MU에서 1 MU 당 선량(cGy/MU)은 6 MV와 10 MV에서 90 MU를 1회에 조사한 것과 비교하여 약 1.6% 정도 증가하였고 2100C는 0.5%, 1.3%가 각각 증가하였다. 600C 또한 1.6% 증가하였으나 6 MU에서 약 3% 차이를 나타내었다. 편평도와 대칭도는 장비와 에너지에 따라 1%에 2.9%까지 차이가 있었으나 전체적으로 적은 MU에서 약간 더 균등하였고 극히 적은 MU로 인한 차이는 확인할 수 없었다. 결 론 : 각각의 실험에서 선량적 차이는 허용되어지는 범위이하의(출력<3%, 편평도<${\pm}3%$, 대칭도<2%, ICRU report 50)오차를 모임으로써 보유한 장비에 따라 정도에 차이는 있을 수 있으나 본원에서 사용 중인 장비에서 극히 적은 MU의 사용이 현저한 선량적 오차를 유발하진 않는 것으로 사료되어진다. 그러나 정도 관리 시 그 오차를 확인하는 과정은 장비의 사용과 수명에 따라 지속적으로 관리되어져야 할 것이다.

  • PDF

타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성 (Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines)

  • 정은교;장재길;송세욱;김정호
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램 (A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems)

  • 김희정;박양균;박종민;최창헌;김정인;이상원;오헌진;임천일;김일한;예성준
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.231-240
    • /
    • 2008
  • 방사선치료계획시스템의 MU계산 결과를 포괄적이고 독립적으로 검증할 수 있고 빔데이터 관리를 위한 사용자 친화적인 프로그램을 개발하였다. 선량계산의 정확성을 향상시키기 위해서 축이탈 인자, 빔 경화효과, 비균질성 보정 등의 요소를 계산 알고리듬에 포함하였고 상시적 정도관리 결과로 측정된 빔데이터로의 경신이 용이하도록 하였다. 기준깊이, SSD 등의 측정조건이 다를 때에 보정하는 알고리듬을 구현하였다. 상용 스프레드시트의 워크시트 함수를 빔데이터베이스 접근에 사용하였고, Visual Basic for Application (VBA) 개발환경을 사용하여 graphic user interface (GUI)를 구현하였다. 프로그램의 정확도를 평가하기 위하여 동일한 빔 데이터를 가진 치료계획 시스템을 이용하여 213개의 경우에 대한 팬톰의 선량을 계산하고 비교하였다. 또한 3차원 입체조형방사선 치료를 받은 17명의 환자데이터로부터 108개의 MU계산 기록을 추출하여 본 프로그램에서 계산된 MU와 비교하였다. 가상의 팬톰을 대상으로 계산을 수행한 결과, 과도한 비균질 영역계산을 제외하면 계산된 MU가 치료계획시스템과 3% 이내에서 잘 일치하였고, 환자 데이터를 이용한 계산에서도 과도한 비균질 영역 계산을 제외한 모든 계산에서 최대오차가 5% 이하로 나타났다. VBA 및 Microsoft Excel 워크시트 인터페이스를 이용하여 임상에 이용될 빔데이터 자료의 자동 생성 및 빔데이터 비교 템플릿 등의 용이성이 판명되었다. 본 프로그램을 이용하여 치료계획시스템의 정확성을 포괄적으로 검증할 수 있으므로 치료계획시스템의 정도관리 및 환자의 독립적 선량검증을 효과적으로 수행할 수 있다. 빔데이터베이스 생성 기능을 이용하여 빔데이터의 주기적 관리 경신 및 대단위 빔데이터베이스의 모니터링을 효율적으로 수행할 수 있다.

  • PDF

Tailored Blank 용접을 위한 감시제어장치 개발 (Development of Monitor & Controller for Tailored Blank Welding)

  • 장영건;유병길;이경돈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.323-327
    • /
    • 1996
  • Gap and thickness difference information between blanks are often necessary for tailored blank welding quality evaluation , optimum welding parameters selection and evaluation of shearing machine, blink allocation device accuracy and clamping device. We develope 3D vision system and camera unit using structured lighting for this purpose. A simple ar d efficient scheme for gap and thickness feature recognition Is developed as well as measurements. Experimental results shows this system measuring accuracy is 10 ${\mu}{\textrm}{m}$ and 16${\mu}{\textrm}{m}$ for gap and thickness difference respectively The data are expexed to be useful for preview gap control.

  • PDF

Building a Graphite Calorimetry System for the Dosimetry of Therapeutic X-ray Beams

  • Kim, In Jung;Kim, Byoung Chul;Kim, Joong Hyun;Chung, Jae-Pil;Kim, Hyun Moon;Yi, Chul-Young
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.810-816
    • /
    • 2017
  • A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak). The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit) for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of $0.798J/{\mu}C$, $0.389J/{\mu}C$, and $0.352J/{\mu}C$ at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

전립선암의 방사선치료에서 토모테라피와 VMAT의 치료계획에 따른 유용성 평가 (Usefulness Evaluation on the Treatment Plan of Tomotherapy and VMAT in Radiotherapy for Prostate Cancer)

  • 허광명;한재복;최남길
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.449-457
    • /
    • 2015
  • 전립선암의 방사선치료에서 토모테라피와 용적변조회전치료(volumetric modulated arc therapy, VMAT)의 치료계획에 따른 유용성 평가를 위해 흡수선량, 선량체적곡선(dose volume histogram, DVH), 치료효율성, MapCHECK2를 이용한 선량 검증 정확도 결과를 각각 비교 분석하였다. 대상으로는 2014년 7월부터 12월까지 H 대학병원 방사선종양학과에서 토모테라피 치료를 받은 전립선암 환자 중 12명을 무작위로 선택하였다. 흡수선량과 DVH를 분석한 결과 종양조직과 방광에서 두 방사선 치료계획이 근소한 차이를 나타냈지만 처방선량의 오차범위인 -5%에서+3%안에 포함됐고 정상조직 부작용 확률 권고치인 견딤선량 범위를 넘지 않았다. 치료시간은 2.5배 짧고 MU(monitor unit)도 10.3배 작아 VMAT가 치료효율성이 높았다. 선량정확도는 모두 95% 이상의 통과기준에 포함 되었으며 VMAT가 2.3% 더 높게 나타났다. 토모테라피와 VMAT 모두 종양조직에 적합한 선량이 흡수되었으며 정상조직의 견딤선량 범위를 넘지 않아 선량분포특성에서 큰 차이는 없었다. 하지만 치료시간이 짧고, total MU가 낮아 치료효율성이 좋고 선량 검증의 정확도 또한 우수한 VMAT를 선택하는 것이 치료에 더 유용할 것으로 사료된다.

두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향 (Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer)

  • 홍주완;정윤주;원희수;장남준;최지훈;석진용
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.105-111
    • /
    • 2010
  • 목 적: 세기변조방사선치료(intensity modulated radiation therapy; IMRT) 계획에는 여러 가지 beam parameter가 적용되어 치료계획을 수립하게 된다. 본 연구에서는 세기변조방사선치료 계획 시 선량율(dose rate) 변화가 이하선 선량에 미치는 영향을 알아보고자 한다. 대상 및 방법: 두경부암 환자 중 비인강암(nasopharyngeal carcinoma, NPC) 세기변조방사선치료를 시행한 10명의 환자를 대상으로 하였다. 동일한 조건하에 환자의 CT영상을 3 mm 두께로 획득하고 치료계획시스템은 Eclipse (Ver 7.1, Varian, Palo Alto, USA)를 사용하였다. 치료계획은 6 MV 에너지, 8개의 조사면, 그리고 동일한 dose volume constraint를 적용하였고, 선량율을 300, 400, 500 MU/min으로 각각 다르게 적용하였다. 수립된 세 개의 치료계획을 통해 이하선 mean dose를 산출하여 10명의 환자 평균치로 분석하였고, 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida)를 사용하여 이하선 부위의 선량을 검증하였다. 그리고 총 Monitor Unit (MU)과 조사시간을 비교하였다. 결 과: 선량율 변화에 따른 이하선 mean dose는 선량율을 300 MU/min에서 400, 500 MU/min 변화 시켰을 때 평균 0.8, 2.0% 증가하였고, 총 MU 또한 평균 5.4, 10.6% 증가하였다. 2D diode Array를 사용한 이하선 부위의 선량측정에서도 증가 추세가 나타났으며 총 조사시간의 차이는 1-2분 정도로 선량율에 따라 큰 변화가 없었다. 결 론: 본 연구결과 선량율이 증가하면 총 MU가 현저히 늘어났고 그에 따라 이하선 선량도 증가하는 유의한 상관관계를 보였으나, 치료시간 단축효과는 크지 않았다. 그러므로 세기변조방사선치료 계획 시 적절한 선량율을 적용하여 이하선 선량을 줄인다면 방사선치료로 인한 이하선의 후기 부작용(late side effect)을 줄일 수 있을 것으로 사료된다.

  • PDF