• Title/Summary/Keyword: Monitor Height

Search Result 103, Processing Time 0.024 seconds

Geoid Determination in South Korea from a Combination of Terrestrial and Airborne Gravity Anomaly Data

  • Jekeli, Christopher;Yang, Hyo Jin;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_2
    • /
    • pp.567-576
    • /
    • 2013
  • The determination of the geoid in South Korea is a national imperative for the modernization of height datums, specifically the orthometric height and the dynamic height, that are used to monitor hydrological systems and environments with accuracy and easy revision, if necessary. The geometric heights above a reference ellipsoid, routinely obtained by GPS, lead immediately to vertical control with respect to the geoid for hydrological purposes if the geoid height above the ellipsoid is known accurately. The geoid height is determined from gravimetric data, traditionally ground data, but in recent times also from airborne data. This paper illustrates the basic concepts for combining these two types of data and gives a preliminary performance assessment of either set or their combination for the determination of the geoid in South Korea. It is shown that the most critical aspect of the combination is the gravitational effect of the topographic masses above the geoid, which, if not properly taken into account, introduces a significant bias of about 8 mgal in the gravity anomalies, and which can lead to geoid height bias errors of up to 10 cm. It is further confirmed and concluded that achieving better than 5 cm precision in geoid heights from gravimetry remains a challenge that can be surmounted only with the proper combination of terrestrial and airborne data, thus realizing higher data resolution over most of South Korea than currently available solely from the airborne data.

Changes in the Health Life of the Elderly Through the Handle Height of Walking Assistant Vehicle Article : Emphasizing on State Anxiety, Heart Rate and Fall Efficacy (보행보조차 손잡이 높이에 따른 노인들의 건강생활의 변화 : 상태불안과 심박수, 낙상효능감을 중심으로)

  • Son, Sung-Min;Kwag, Sung-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.519-528
    • /
    • 2020
  • Purpose of this study is to analyze the changes in state anxiety, heart rate, and fall efficacy of the elderly through the handle height of walking assistant vehicle (WAV). The subjects were 32 elderlies. WAV was in the form of strollers, and it's handle height was set as 48% of a subject's total height. Also, it's height was divided into 48, 43, 38%. To measure the state anxiety, Korean State-Trait Anxiety Inventory was used and to measure the heart rate, Fitbit Charge 2 wrist heart rate monitor was used. To measure the fall efficacy, Fall Efficacy Scale-Korea was used. As the results of state anxiety and heart rate, the statistically significant increase showed continuously through the decrease of the handle height of WAV. As the results of fall efficacy, the statistically significant decrease showed continuously through the decrease of the handle height of WAV. In all of the post hoc test, the results of the state anxiety and fall efficacy showed significant difference among the each handle height of WAV and the results of the heart rate showed significant difference between the 48, 43% and 38% handle height of WAV. Thus, to decrease the state anxiety and heart rate and increase the fall efficacy of the elderly, the handle height of WAV should be properly positioned and considered to adjust to 48% of the user's total height.

Effect of Visual Block, Task Type, and Participation in an Exercise Program on Static Balance in the Elderly (시각 차단, 과제 유형, 및 운동프로그램 참여가 노인의 정적 균형에 미치는 영향)

  • Woo, Young-Keun;Yi, Chung-Hwi;Cho, Sang-Hyun;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.1-15
    • /
    • 2003
  • The purpose of this study was to assess the effect of visual block (eyes open or closed), mental task type, and participation in an exercise program on static balance in the elderly. The subjects were 34 elderly (>65 years old) residents of a social welfare institute in Gyeonggi-do. We measured the following variables. Berg balance scale, mini mental state examination, balance performance monitor (sway area, path, and maximal sway velocity), age, weight, height and whether the subject participated in an exercise program. Scores for the Berg balance scale and mini mental state examination were evaluated to assess static balance ability either alone (single task paradigm) or while performing a mental task (dual task paradigm). Static balance variables that were measured included sway area, path, and maximal sway velocity. Each test was repeated three times. Multiple regressions analysis was used to examine the effect of each variable on static balance ability. For the dual task paradigm, static balance was affected by whether the subject participated in an exercise program. The Berg balance scale score for subjects with their eyes open was affected by whether they participated in an exercise program, while this variable in addition to the height and weight of subjects were determining variables in subjects with their eyes closed. As a result, whether subjects participated in an exercise program affected their static balance irrespective of whether their eyes open or closed. Therefore, regular exercise is recommended for elderly people and further research is needed to examine the relationship between static and dynamic balance while performing mental tasks such as cognition and attention.

  • PDF

Monitoring The Children's Health Status and Forecasting Height with Nutritional Advice

  • Nguyen, Kim Ngan;Ton, Nu Hoang Vi;Vu, Tran Minh Khuong;Bao, Pham The
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.680-692
    • /
    • 2018
  • Children's health is interesting to parents and society. A system that assists to monitor the development of their children and gives nutritional advices is an interesting of parents. In this study, we present a system that allows to track the heights and weights of a child since he/she was born up to adulthood, to predict his age of puberty, and to provide nutritional advice. Particularly, it predicts the height in near future and the adult stature for detecting the child with abnormal development. We applied Sager's model for predicting the height in near future by using interpolation and regression techniques before puberty. After determining the puberty time, we proposed a model for predicting the height. Then we applied fuzzy logic for evaluating the health status and providing nutritional advice. Our system predicted stature in near future with error bound of $1.7361{\pm}0.0397cm$ in girls and $2.4020{\pm}0.0799cm$ in boys. Our model also gave a reliable adult stature prediction with error bound of $0.3507{\pm}0.2808cm$ in girls and $1.3414{\pm}0.7024cm$ in boys. At the same time, the nutrition was provided appropriately in terms of protein, lipid, glucid. We implemented a program based on this research. Our system promises to improve the health of every child.

Factors influencing Video Display Terminal Syndrome in Clinical Nurses (임상간호사의 영상표시단말기 증후군 및 영향요인)

  • Kwon, Yunhee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.4
    • /
    • pp.485-494
    • /
    • 2016
  • Purpose: The present research is a descriptive study aimed at understanding clinical nurses' Video display terminal (VDT) syndrome and identifying the factors that affect their VDT syndrome. Methods: Data were collected from 239 clinical nurses working in two metropolitan cities. Research tools included subject's VDT syndrome assessing musculoskeletal, ophthalmic, dermal, psychiatric, and whole body syndromes. The data were analyzed using frequency analysis, average and standard deviation, t-test, One-way ANOVA, and multiple regression analysis with the SPSS/WIN 20.0 program. Results: The subjects' VDT syndrome score was 1.34 out of 5. There were significant differences in participating subjects' VDT syndrome, hospital's size, working unit, health status, diagnosis of illness, having an Order Communication System (OCS), having an Electronic Medical Record (EMR) System, continuous VDT working for more than one hour, break time during VDT use, VDT use time, comfort of the chair, adjustability of the height of the chair, size of the VDT's desk, distance between the monitor and the user's eyes, resolution of the monitor, and frequency of eye exercise during VDT use. According to the research, influencing factors on VDT syndrome in clinical nurses included size of the VDT's desk, frequency of eye exercise during VDT use, having an EMR system, break time during VDT use, diagnosis illness, and having an OCS' system. Conclusion: The findings from this study can be used as a basis for future VDT syndrome prevention education and programs for clinical nurses.

Achalasia Previously Diagnosed as Gastroesophageal Reflux Disease by Relying on Esophageal Impedance-pH Monitoring: Use of High-Resolution Esophageal Manometry in Children

  • Pyun, Jung Eun;Choi, Da Min;Lee, Jung Hwa;Yoo, Kee Hwan;Shim, Jung Ok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.18 no.1
    • /
    • pp.55-59
    • /
    • 2015
  • Gastroesophageal reflux disorder (GERD) is the most common esophageal disorder in children. Achalasia occurs less commonly but has similar symptoms to GERD. A nine-year old boy presented with vomiting, heartburn, and nocturnal cough. The esophageal impedance-pH monitor revealed nonacidic GERD (all-refluxate clearance percent time of 20.9%). His symptoms persisted despite medical treatment for GERD, and he was lost to follow up. Four years later, he presented with heartburn, solid-food dysphagia, daily post-prandial vomiting, and failure to thrive. Endoscopy showed a severely dilated esophagus with candidiasis. High-resolution manometry was performed, and he was diagnosed with classic achalasia (also known as type I). His symptoms resolved after two pneumatic dilatation procedures, and his weight and height began to catch up to his peers. Clinicians might consider using high-resolution manometry in children with atypical GERD even after evaluation with an impedance-pH monitor.

Tube phonation in water for patients with hyperfunctional voice disorders: The effect of tube diameter and water immersion depth on bubble height and maximum phonation time (과기능적 음성장애 환자의 물저항발성: 튜브 직경과 물 깊이가 물거품 높이 및 최대발성지속시간에 미치는 영향)

  • Min Gyeong Kim;Seong Hee Choi;Jong-In Youn
    • Phonetics and Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.31-40
    • /
    • 2023
  • Tube phonation in water has been widely used for voice training among semi-occluded vocal tract (SOVT) exercises in which the patient bubbles with phonation keeping the tube submerged in water. This study aims to investigate the effect of tube diameter and water depth on bubble height and maximum phonation time (MPT) for patients with hyperfunctional voice disorders. Seventeen patients with hyperfunctional voice disorders were asked to bubble with sustained /u/ at the different inner diameters of tube (5, 7, and 10 mm), water depth (4, 7, and 10 cm). A water resistance phonation biofeedback system using a water height sensor was used for recording bubble height and MPT. The bubble height was significantly changed by the tube diameter while MPT was significantly changed with the tube diameter and water depth. Although the wider tube presented significantly lower bubble height for a given depth, relatively consistent bubble height was maintained. Depending on the water depth, the bubble height did not significantly differ for a given tube diameter. In addtion, MPT significantly decreased with water depth and a wider tube led significantly shorter MPT. A water level-driven water resistance biofeedback system provided useful information on bubble characteristics and vocal fold vibration depending on tube diameter and water depth. It can be useful to monitor the breath support during water resistance phonation for patients with hyperfunctional voice disorders.

PIEZOELECTRIC VERTICAL BONE AUGMENTATION USING SANDWICH TECHNIQUE IN ATROPHIC MANDIBLE: TWO CASES REPORT (Sandwich technique을 이용한 하악골 증대술의 치험 보고)

  • Lee, Ji-Soo;Lee, Jung-Kwang;Lee, Hyun-Jin;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.276-282
    • /
    • 2008
  • Objective: This is to report the efficacy of the sandwich technique for bone augmentation in a moderate atrophic posterior mandible through clinical and histological results in two cases. Subjects and Method: Two patients selected had moderate bone resorption in left lower edentulous area. Sandwich osteotomy using the piezosurgery was performed and the osteomized alveolar segments were elevated by 6mm in each two patients. The interpositional mineral allograft materials were inserted in the atrophic posterior mandibles. After four months healing period, bone biopsies in the grafted areas and placement of dental implants were performed. In both cases, panoramic views were taken preoperatively to measure the alveolar bone height for diagnosis, to monitor patient healing, and to evaluate bone healing and bone gain. Results: Sufficient vertical bone height was gained by using the sandwich technique and implants were placed successfully. In radiological evaluation, there was minimal resorption of bone height after the second operation and in histomorphometric evaluation, they showed favorable new bone formation without inflammation in the grafted areas. Conclusion: The sandwich technique can be an effective choice for augmenting vertical bone height in the atrophic mandible. More of cases and long term follow-up are needed to evaluate bone resorption and implant prognosis.

Lower Extremity Muscle Activity on the Obstacle Gait in Older Parkinson Diseases (파킨슨 환자들의 장애물 보행 향상을 위한 하지의 근육 활동 규명)

  • Lim, Bee-Oh;Kim, Mi-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.141-148
    • /
    • 2007
  • Falls associated with tripping over an obstacle can be dangerous, yet little is known about the strategies used for stepping over obstacles in older Parkinson disease. The purpose of this study was to investigate the lower extremity muscle activity on the obstacle gait according to obstacle height in older Parkinson diseases. The obstacle gait of 7 older Parkinson disease was examined during a 5.0 m approach to, and while stepping over, obstacles of 0, 25, 52, and 152mm. Seven pairs of surface electrodes(Noraxon MyoResearch, USA) were attached to the right-hand side of the body to monitor the adductor longus(AL), gluteus medius(GME), gluteus maximus(GMA), biceps femoris(BF), rectus femoris(RF), gastrocnemius(GA), tibialis anterior(TA). Electromyography data were filtered using a 10Hz to 350 Hz Butterworth band-pass digital filter and normalized to the maximum value in the analyzed phases. A one-way ANOVA for repeated measures was employed for selected electromyography variables to analyze the differences of the height of four obstacles. The results showed significant differences between 0.0mm and 25, 52, and 152mm obstacle height in TA and GA activities during the second phase(swing phase). But the more increase obstacle height, the more not increase the muscle activities. This means that the Parkinson disease stepping over obstacle inefficiency. To prevent and reduce the frequency of falls, elderly Parkinson disease maintained and improved their balance, muscular strength, neuromuscular control and mobility.

Ground-based Observations of the Polar Region Space Environment at the Jang Bogo Station, Antarctica

  • Kwon, Hyuck-Jin;Lee, Changsup;Jee, Geonhwa;Ham, Young-Bae;Kim, Jeong-Han;Kim, Yong Ha;Kim, Khan-Hyuk;Wu, Qian;Bullett, Terence;Oh, Suyeon;Kwak, Young-Sil
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.185-193
    • /
    • 2018
  • Jang Bogo Station (JBS), the second Korean Antarctic research station, was established in Terra Nova Bay, Antarctica ($74.62^{\circ}S$ $164.22^{\circ}E$) in February 2014 in order to expand the Korea Polar Research Institute (KOPRI) research capabilities. One of the main research areas at JBS is space environmental research. The goal of the research is to better understand the general characteristics of the polar region ionosphere and thermosphere and their responses to solar wind and the magnetosphere. Ground-based observations at JBS for upper atmospheric wind and temperature measurements using the Fabry-Perot Interferometer (FPI) began in March 2014. Ionospheric radar (VIPIR) measurements have been collected since 2015 to monitor the state of the polar ionosphere for electron density height profiles, horizontal density gradients, and ion drifts. To investigate the magnetosphere and geomagnetic field variations, a search-coil magnetometer and vector magnetometer were installed in 2017 and 2018, respectively. Since JBS is positioned in an ideal location for auroral observations, we installed an auroral all-sky imager with a color sensor in January 2018 to study substorms as well as auroras. In addition to these observations, we are also operating a proton auroral imager, airglow imager, global positioning system total electron content (GPS TEC)/scintillation monitor, and neutron monitor in collaboration with other institutes. In this article, we briefly introduce the observational activities performed at JBS and the preliminary results of these observations.