• Title/Summary/Keyword: Molecular pump

Search Result 108, Processing Time 0.029 seconds

Effect of Clearance between a Rotor and Stator of a Disk-Type Drag Pump on the Pumping Performance (고속 회전하는 원판형 드래그펌프 회전익과 고정익 사이 간극이 배기 성능에 미치는 영향)

  • Kwon, Myoung-Keun;Lee, Soo-Yong;Hwang, Young-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1640-1645
    • /
    • 2004
  • The pumping characteristics of a single-stage disk-type drag pump ( DTDP ) are calculated,for the variation of the vertical clearance between a rotor and stator and of the radial clearance between a rotor and casing wall, by the three-dimensional direct simulation Monte Carlo (DSMC)method. The gas flow mainly belongs to the molecular transition flow region. Spiral channels of a DTDP are cut on the both the upper and lower sides of a rotating disk, but the stationary disks are planar. As a consequence of results, the vertical and radial clearances have a significant effect on the pumping performance. Experiments are performed under the outlet pressure range of 0.4 $^{\sim}$ 533 Pa. When the numerical results are compared to the experimental data, the numerical results agree well qualitatively.

  • PDF

Rarefied Gas Flows in Spiral Channels of a Disk-Type Drag Pump (원판형 드래그펌프내의 희박기체유동)

  • Hwang, Young-Kyu;Heo, Joons-Sik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.82-87
    • /
    • 2000
  • The direct simulation Monte Carlo (DSMC) method is applied to investigate the flow field of a disk-type drag pump. The pumping channels are cut on both sides of a rotating disk. The rotor has 10 Archimedes' spiral blades. In the present DSMC method, the variable hard sphere model is used as a molecular model, and the no time counter method is employed as a collision sampling technique. For simulation of diatomic gas flows, the Larsen-Borgnakke phenomenological model is adopted to redistribute the translational and internal energies.

  • PDF

Effect of Vertical Clearance Between a Rotor and Stater of a Disk-Type Drag Pump on the Performance (원판형 드래그펌프 회전자와 고정자 사이의 간극이 성능에 미치는 영향)

  • Kwon, Myoung-Keun;Hwang, Young-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1501-1510
    • /
    • 2004
  • The pumping characteristics of a single-stage disk-type drag pump (DTDP) are calculated for the variation of the vertical clearance between a rotor and stator by the three-dimensional direct simulation Monte Carlo (DSMC) method. The gas flow mainly belongs to the molecular transition flow region. Spiral channels of a DTDP are cut on the both the upper and lower sides of a rotating disk, but a stationary disk is planar. The interaction between molecules is described by the variable hard-sphere model. The no time counter method is used as a collision sampling technique. The vertical clearance has a significant effect on the pumping performance. Experiments are performed under the outlet pressure range of 0.4∼533 Pa. When the numerical results are compared with the experimental data, the numerical results agree well quantitatively

Ultralow Intensity Noise Pulse Train from an All-fiber Nonlinear Amplifying Loop Mirror-based Femtosecond Laser

  • Dohyeon Kwon;Dohyun Kim
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.708-713
    • /
    • 2023
  • A robust all-fiber nonlinear amplifying loop-mirror-based mode-locked femtosecond laser is demonstrated. Power-dependent nonlinear phase shift in a Sagnac loop enables stable and power-efficient mode-locking working as an artificial saturable absorber. The pump power is adjusted to achieve the lowest intensity noise for stable long-term operation. The minimum pump power for mode-locking is 180 mW, and the optimal pump power is 300 mW. The lowest integrated root-mean-square relative intensity noise of a free-running mode-locked laser is 0.009% [integration bandwidth: 1 Hz-10 MHz]. The long-term repetition-rate instability of a free-running mode-locked laser is 10-7 over 1,000 s averaging time. The repetition-rate phase noise scaled at 10-GHz carrier is -122 dBc/Hz at 10 kHz Fourier frequency. The demonstrated method can be applied as a seed source in high-precision real-time mid-infrared molecular spectroscopy.

Oxidative Stress Is Decreased in Off-pump Versus On-pump Coronary Artery Surgery

  • Gonenc, Aymelek;Haclsevki, Aysun;Bakkaloglu, Beyhan;Soyaglr, Aylin;Torun, Meral;Karagoz, Haldun;Simsek, Bolkan
    • BMB Reports
    • /
    • v.39 no.4
    • /
    • pp.377-382
    • /
    • 2006
  • Oxidative stress occurs in patients undergoing coronary artery bypass operation. The aim of this study was to investigate the difference in oxidative stress in off-pump versus on-pump coronary artery bypass surgery. In the present study, in serial blood samples, plasma malondialdehyde (MDA) as index of lipid peroxidation, red blood cells glutathione peroxidase (GPx) and superoxide dismutase (SOD) were measured to compare the extent of oxidative stress in 30 patients undergoing OPCAB (off-pump coronary artery bypass grafting), 12 patients undergoing CABG (on-pump coronary artery bypass grafting) and 18 healthy controls. In CABG group, MDA levels increased significantly from $2.87{\pm}0.62\;nmol/mL$ before anesthesia and $2.87{\pm}0.65\;nmol/mL$ after anesthesia to $3.05{\pm}0.66\;nmol/mL$ after ischemia (p < 0.05). Similarly, SOD levels also elevated significantly from $661.58{\pm}78.70\;U/g$ Hb before anesthesia and $659.42{\pm}81.21\;U/g$ Hb anesthesia induction to $678.08{\pm}75.80\;U/g$ Hb after ischemia (p < 0.01, p < 0.01, respectively). In OPCAB group, only SOD levels increased from $581.73{\pm}86.24\;U/g$ Hb anesthesia induction to $590.90{\pm}88.90\;U/g$ Hb after reperfusion (p < 0.05). Glutathione peroxidase levels were not changed according to blood collection times in both of CABG group or OPCAB group (p > 0.05). Our results show that only mild signs of oxidative stress is found after reperfusion in OPCAB operation compared with CABG operation. Further studies are needed in order to confirm this hypothesis.

Molecular Aspects of Organic Ion Transporters in the Kidney

  • Cha, Seok-Ho;Endou, Hitoshi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.107-122
    • /
    • 2001
  • A function of the kidney is elimination of a variety of xenobiotics ingested and wasted endogenous compounds from the body. Organic anion and cation transport systems play important roles to protect the body from harmful substances. The renal proximal tubule is the primary site of carrier-mediated transport from blood into urine. During the last decade, molecular cloning has identified several families of multispecific organic anion and cation transporters, such as organic anion transporter (OAT), organic cation transporter (OCT), and organic anion-transporting polypeptide (oatp). Additional findings also suggested ATP-dependent organic ion transporters such as MDR1/P-glycoprotein and the multidrug resistance-associated protein (MRP) as efflux pump. The substrate specificity of these transporters is multispecific. These transporters also play an important role as drug transporters. Studies on their functional properties and localization provide information in renal handling of drugs. This review summarizes the latest knowledge on molecular properties and pharmacological significance of renal organic ion transporters.

  • PDF

Efficiency Analysis of Thermal Transpiration According to Knudsen Number for Application to Micro-propulsion System (마이크로 추진장치에 적용을 위한 누센수에 따른 열적발산원리의 효율분석)

  • Jung, Sung-Chul;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.5
    • /
    • pp.483-490
    • /
    • 2008
  • Minimization of nozzle induces many flow losses in micro-propulsion system. In this study, we studied about thermal transpiration based micro propulsion system to overcome these losses. Thermal transpiration device(Knudsen pump) having no moving parts can self-pump the gaseous propellant by temperature gradient only (cold to hot). We designed, fabricated the Knudsen pump and analyzed pressure gradient efficiency of membrane according to Knudsen number under vacuum condition. Experimental results showed that thick membranes are more effective than thin membranes in transition flow regime, and pressure gradient efficiency according to Knudsen number is increased to maximum 82% apart from membrane thickness in free molecular regime.

The Effect on Performance of Disk-type Drag Pump Channel-type (원판형 드래그펌프 채널형상의 성능에 미치는 영향)

  • Kwon, Myoung-Keun;Lee, Seung-Jae;Hwang, Young-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.816-821
    • /
    • 2003
  • The pumping characteristics of a disk-type drag pump (DTDP) from free molecular flow region to the slip flow region are calculated by the direct simulation Monte Carlo (DSMC) method. In this study, the pumping performance is studied numerically for several channel depths. The interaction between molecules is modeled by variable hard-sphere (VHS). The no time counter method is used as a collision sampling technique. The clearance between rotor and stator is considered an effect on performance. Spiral channels are cut on both upper and lower sides of rotating disks, and stationary disks are planar. A three-dimensional DSMC method for the analysis of steady rarefied flows in a single-stage DTDP has been developed. Velocity and density fields were obtained by the DSMC simulation in the rotor. The present experimental data in the outlet pressure range of $7.5{\times}10^{-3}{\sim}4$ Torr were compared with the DSMC results in the single-stage DTDP. Comparison between the experimental data and DSMC results showed good agreement.

  • PDF

Effects of Collection Methods on Recovery Efficiency, Maturation Rate and Subsequent Embryonic Developmental Competence of Oocytes in Holstein Cow

  • Wang, Zheng-guang;Yu, Song-dong;Xu, Zi-rong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.4
    • /
    • pp.496-500
    • /
    • 2007
  • Holstein cow ovaries obtained at a slaughterhouse were used to study the influence of the oocyte collection methods (slicing, puncture, aspiration I and II) on recovery efficiency and subsequent in vitro maturation and embryonic development competence of immature oocytes recovered. In the slicing method, the whole ovarian was chopped into small pieces with a surgical blade. In the puncture method, the whole ovarian surface was punctured by 18-g needle. In other 2 aspiration methods, collected oocytes by aspirating from the visible follicles using an 18-g needle attached to a 5 ml syringe (aspiration I) or using a constant negetive pressure (-80 mmHg) with a vacuum pump (aspiration II). The oocytes were classified into 4 classes on the basis of the morphology of cumulus cells and cytoplasmic appearance of oocyte. Slicing ($9.6{\pm}0.4$) and puncture ($9.7{\pm}0.4$)yielded a larger number of oocytes per ovary than other two aspiration methods (aspiration I and II were $5.8{\pm}0.3$and $5.6{\pm}0.4$, respectively) (p<0.05). The number of the highest quality oocytes (grade A) per ovary was significantly higher in slicing ($4.2{\pm}0.2$) and puncture ($4.6{\pm}0.1$) methods than in other methods (aspiration I and II were $1.2{\pm}0.2$ and $1.4{\pm}0.2$, respectively) (p<0.05). The rate of nuclear maturation of the highest and higher quality oocytes (grade A and grade B, respectively) was not affected by the oocytes collection methods. The oocytes collection methods also did not influence subsequent embryonic developmental competence after in vitro fertilization with M II stage oocytes. It is concluded that slicing and puncture methods of the ovaries can be used as an alternative techniques to aspiration by the syringe or vacuum pump.