Development of High Precision Machining Technology (초정밀 표면 형상 가공기술 개발)

  • 이응숙
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.435-440
    • /
    • 2000
  • In this study, we aims to develop the machining technology for the ultra precision surface and profile accuracy. For this purpose, we construct the electrolytic in process grinding system (ELID grinding) and apply to the cylindrical and internal grinding. Through the various machining experiments such as SCM steel., ceramics, tungsten carbide etc., we have obtained nanometer surface roughness. And we have applied this mirror grinding technique to hydraulic manual valve and mold core of mini disk optical pick-up base. For the development of fine mechanical part machining technology, e have made multi fiber optical connector using fine grinding technology. And constructed micro drilling system with process monitoring system which is possible to drill 50${\mu}{\textrm}{m}$ diameter hole.

  • PDF

A Study on the Deteriorated Cause Analysis of Mold Type Potential Transformer (몰드형 계기용 변압기의 소손원인 해석에 관한 연구)

  • Choi, Chung-Seog;Kim, Hyug-Soo;Shong, Kil-Mok;Kim, Hyung-Rae;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1557-1559
    • /
    • 2000
  • In this paper, we intend to establish the judgement of electrical fire through analysis of PT(Potential Transformer) using the power installation. The columnar structure and the void generated by abrupt heat grew at the tenter of boundary-face on the metallurgical microscope analysis. The detection of OK lines was confirmed by EDX(Energy Dispersive X-ray spectroscopy) as melting and recombination due to the layer-short of the wiring. We found that the thermal-weight decrease occurred at 300$^{\circ}C$ in case of being the thermal-deterioration on the base of the result that analyzed the insulated-materials by using TGA, and the thermal reaction limited-value of PT insulator was about 300$^{\circ}C$ on the DSC curve. As this analysis, we confirmed what the layer-short appeared in the wiring of PT.

  • PDF

Investigation of Adhesion Mechanism at the Metal-Organic Interface Modified by Plasma - Part I

  • Sun, Yong-Bin
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.123-126
    • /
    • 2002
  • For the mold die sticking mechanism, the major explanation is that EMC filler of silica wears die surface roughened, which results in increase of adhesion strength. As big differences in experimental results from semiconductor manufacturers are dependent on EMC models, however, chemisorptions or acid-base interaction is apt to be also functioning as major mechanisms. In this investigation, the plasma source ion implantation (PSII) using $O_2$, $N_2$, and $CF_4$ modifies sample surface to form a new dense layer and improve surface hardness, and change metal surface condition from hydrophilic to hydrophobic and vice versa. Through surface energy quantification by measuring contact angle and surface ion coupling state analysis by Auger, major governing mechanism for sticking issue was figured out to be a complex of mechanical and chemical factors.

  • PDF

Investigation of Adhesion Mechanism at the Metal-Organic Interface Modified by Plasma Part I

  • Sun, Yong-Bin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.4
    • /
    • pp.31-34
    • /
    • 2002
  • For the mold die sticking mechanism, the major explanation is that the silica as a filler in EMC (epoxy molding compound) wears die surface to be roughened, which results in increase of adhesion strength. As the sticking behavior, however, showed strong dependency on the EMC models based on the experimental results from different semiconductor manufacturers, chemisorption or acid-base interaction is apt to be also functioning as major mechanisms. In this investigation, the plasma source ion implantation (PSII) using $O_2, N_2$, and $CF_4$ modifies sample surface to form a new dense layer and improve surface hardness, and change metal surface condition from hydrophilic to hydrophobic or vice versa. Through surface energy quantification by measuring contact angle and surface ion coupling state analysis by Auger, major governing mechanism for sticking issue was figured out to be a complex of mechanical and chemical factors.

  • PDF

Plasma Aided Process As Alternative to Hard Chromium Electroplating

  • Kwon, Sik-Chol;Lee, K.H.;Kim, J.K.;Kim, M.;Lee, G.H.;Nam, K.S.;Kim, D.;Chang, D.Y.
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.1
    • /
    • pp.48-58
    • /
    • 2003
  • This paper will present an overview of toxicity of hexavalent chromium as well as effort for its replacement by a wide spectrum of alternative materials and technologies. Cr-based materials such as trivalent electrodeposit will be one of strong candidates for hard chromium by surface modification of its surface hardness. Ni-base alloy deposits has proved its application in specific mold for glass. HVOF has been studied in aircraft and military sector. There are still under way of development for commercially available alternatives. To date, no single coating has been identified as universal process as comparable to conventional hard chromium electroplating.

A Study on the Form Accuracy Improvement of Mold Core for F-Theta Lens (F-Theta Lens 금형코어 형상정도 향상에 관한 연구)

  • Kim S.S.;Jeong S.H.;Kim H.U.;Kim H.J.;Kim J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.777-780
    • /
    • 2005
  • The global consumption of aspheric surfaces will expand rapidly on the Electronics and Optical Components Information and Communications, Aerospace and Defense, and Medical optics markets etc. We must research on market, technology forecast and analysis of aspheric surfaces that is a principle step of ultra precision machine technology with a base one of optical elements. Especially, F-theta lens is one of the important parts in LSU(Laser scanning unit) because it affects on the optical performance of LSU dominantly. The core is most of important to produce plastic F-theta lens by plastic injection molding method, which is necessary to get the ultra-precision aspheric and non-axisymmetric machine processing technology.

  • PDF

The Development of 3D based On-Machine Measurement Operating System (3D 기반의 기상측정 운영시스템 개발)

  • 윤길상;최진화;조명우;김찬우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.145-152
    • /
    • 2004
  • This paper proposed efficient manufacturing system using the OMM (on-machine measurement) system. The OMM system is software based 3D modeler for inspection on machine and it is interfaced tool machine with RS232C. The software is composed of two inspection modules that one is touch probe operating module and the other is laser displacement sensor operating module. The module for touch probe has need of inspection feature that extracted it from CAD data. Touch probe moves to workpiece by three operating modes as follows: manual, general and automatic mode. The operating module of laser displacement sensor is used inspection for profile and very small hole. An Advantage of this inspection method is to be able to execute on-line inspection during machining or after it. The efficiency of proposed system which can predict and definite the machining errors of each process is verified, so the developed system is applied to inspect the mold-base(cavity, core).

Evaluation of Microhardness of Bulk-base Composite Resins According to the Depth of Cure (Bulk-base 복합 레진의 중합 깊이에 따른 미세경도 평가)

  • No, Yoomi;Shin, Bisol;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.335-340
    • /
    • 2017
  • Composite resin becomes an essential material in pediatric dentistry. However, incremental filling of composite resin to minimize the polymerization shrinkage takes time. To reduce the polymerization shrinkage, clinicians and researchers have focused on bulk-filling materials. Bulk-base composite resin is newly introduced as bulk-filling composite resin. The purpose of this study was to evaluate microhardness profile of bulk-base composite resin according to the depth of cure. A high flow bulk-base material and a low flow bulk-base material were used for experimental group, and a conventional composite resin was used for control group. Each group consist of 20 specimens, $3.5{\times}3.5{\times}5.0mm$ mold was used to make specimen. Specimens were sectioned at the 2 mm and the 3 mm depth with milling machine. Microhardness profile was measured at the surface, 2 mm depth, 3 mm depth, and 4 mm depth. Microhardness of control group showed statistically significant difference (p < 0.05) according to the polymerization depth. In contrast, experimental group showed no statistically significant difference, except between 0 mm and 4 mm at HFB, 0 mm and 2 mm, 0 mm and 3 mm at MFB. At the surface and the 2 mm depth, the control group showed higher microhardness than the experimental groups (p < 0.05). However, at the 4 mm depth, the experimental groups showed significantly higher microhardness (p < 0.05). The results from this study, the bulk-base composite resin showed higher microhardness at the 4 mm and lower microhardness at the surface and the 2 mm depth. Therefore, if bulk-base resin overcomes the mechanical weakness, it could be considered using in pediatric dentistry.

Occurrence of Gray Mold Caused by Botrytis cinerea on Okra in Korea (Botrytis cinerea에 의한 오크라 잿빛곰팡이병)

  • Choi, JangNam;Choi, InYoung;Lee, KuiJae;Lee, JungNo;Cho, SeongWan;Shin, HyeonDong;Galea, Victor
    • Research in Plant Disease
    • /
    • v.24 no.4
    • /
    • pp.302-307
    • /
    • 2018
  • From 2014 to 2016, approximately 5% of okra fruit were observed displaying gray mold symptoms at the research field of Jeollabuk-do Agricultural Research and Extension Services, Korea. The symptoms observed were water-soaked, brown or gray spots, and abundant mycelial with conidia appearing on the infected fruit. Initial infection commenced from the base of fruit and gradually moved to the pod, where it finally resulted in collapse. Colonies on potato dextrose agar were gray to grayish brown, felted and cottony expanding 65-80 mm after one week. The fungus formed several black sclerotia ranging $1.0-3.5{\times}0.5-3.0mm$ on the Petri dish after two weeks. The conidia were one-celled, ellipsoidal or ovoid, colorless or pale brown, and $6.2-15.4{\times}5.0-10.4{\mu}m$. Conidiophores arose solitary or in groups, straight or flexuous, septate, with an inflated basal cell brown to light brown, and measured $85-450{\times}10.0-40.0{\mu}m$. On the basis of the morphological characteristics and phylogenetic analyses of internal transcribed spacer rDNA, the fungus was identified as Botrytis cinerea Pers. Pathogenicity of a representative isolate was proved by artificial inoculation, fulfilling Koch's postulates. To our knowledge, this is the first report on the occurrence of B. cinerea on okra in Korea.

Treatment of Edentulous Patient with Neutral Zone Technique : A Clinical Case (무치악 환자 에서 Neutral Zone 방법을 적용한 임상 증례)

  • Kim, Yongsik;Lee, Byunguk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.2
    • /
    • pp.107-112
    • /
    • 2001
  • The prosthodontic treatment of severely resorbed edentulous patients has been one of the frustrating areas due to extensive loss of tissues. The integrated neuromuscular balance among tongue, lip, and cheek is compromised. The retention, stability, and support are the three major factors to influence the clinical outcome. Fish described a denture as having three surface, with each surface playing an independent and important role in the over all fit, stability, and comfort of the denture. He recommended that the polished surface should be a series of inclines so that pressure from muscular activity will retain dentures. Within the denture space there is an area that has been termed the neutral zone. The neutral zone is that area in the mouth where, during function, the forces of the tongue pressing outward are neutralized by the forces of the cheeks and lips pressing inward. According to Jacobson and Krol, neuromuscular control interacts to provide retention and the relationship of polished surface of denture base to the surrounding muscular structure of orofacial capsule facilitates the stability and retention. This neutral zone concept has been demonstrated with various modification by a number of authors. The theory used to develop the denture base contours is based on the belief that the muscle should functionally mold not only the border but the entire polished surface. Lott and Walsh reported the clinical success on complete mandibular dentures with application of neutral zone concept. A number of studies demonstrated that denture stability and retention are more dependent on correct position of the teeth and correct contour of external surfaces of the denture in a severely resorbed alveolar ridge. This article presents a prosthodontic approach to treatment of a edentulous patient using neutral zone technique to improve the retention and stability of the prosthesis.

  • PDF