• Title/Summary/Keyword: Moisture meter

Search Result 96, Processing Time 0.026 seconds

Comparison of Equilibrium Moisture Contents for Conventional Kiln Dried- and High Temperature Dried Softwood Lumber by Moisture Content Determination (관행열기건조(慣行熱氣乾操)와 고온건조(高溫乾燥) 침엽수재(針葉樹材)의 함수율(含水率) 측정법(測定法)에 의한 평형함수율(平衡含水率) 비교(比較))

  • Jung, Hee-Suk;Smith, William B.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.37-42
    • /
    • 1994
  • The adsorption of water vapor and equilibrium moisture content(EMC) of the specimens for four softwood species dried by conventional- and high temperature method and equilibrated to 15% of the target EMC condition at 25$^{\circ}C$ were determined by oven drying method and with moisture meters. The amount of adsorption for high temperature dried red pine was significantly higher than that of conventional kiln dried wood, while those of eastern white pine, eastern hemlock and Norway spruce were not significantly different between drying methods. EMCs of these four species determined by oven drying method and with capacitive admittance moisture meter were not significantly different between drying methods. EMC of high temperature dried red pine determined with resistance moisture meter was significantly higher than that of conventional kiln dried wood. But EMCs of other species did not show significant difference between drying methods. EMCs of conventional and high-temperature dried wood determined with electronic moisture meters, especially in the case of the capacitive-admittance moisture meter measurement, were lower than that determined by oven drying method.

  • PDF

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

Effects of Density, Temperature, Size, Grain Angle of Wood Materials on Nondestructive Moisture Meters

  • Pang, Sung-Jun;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.40-50
    • /
    • 2019
  • The aim of this study was to investigate the effects of density, temperature, size, and grain direction on measurement of moisture contents (MC) of wood materials non-destructively. The MC of different sizes of solid wood, glulam, and CLT from larch (larix kaempferi, $560kg/m^3$) and pine (pinus koraiensis, $430kg/m^3$) were measured using the dielectric type and resistance type meters. The specimens were conditioned in the environmental chamber to be equilibrium moisture content (EMC) of 12 % and 19 %. When density setting in dielectric type meter was increased from $400kg/m^3$ to $600kg/m^3$, the MCs of specimen (S-L-100-E) were decreased from 13.4 % to 11.3 %. However, when wood group (WG) setting in resistance type meter was changed from WG1 to WG4, the measured MCs were increased from 9.2 % to 12.3 %. When temperature setting in resistance type meters was changed from 0 to $35^{\circ}C$, the MC was decreased from 17.0 % to 13.0 %. The MCs measured by dielectric type meter for larger specimens (S-L-100-E_11.3 %, G-L-240-E_11.7 % and C-L-120-E_12.8 %) were higher than those of small size specimens (S-L-30-E_8.7 %, G-L-150-E_10.3 %, and C-L-90-E_9.7 %). The MCs measured by resistance type meter for larger specimens (G-L-240-E_11.6 % and C-L-120-E_13.3 %) were also higher than those of small size specimens (G-L-150-E_10.4 %, and C-L-90-E_11.8 %). The resistance type meter was not affected by the grain direction but the dielectric type meter were affected by the grain direction. The MC measured by resistance type meter for G-L-120-E perpendicular to grain direction was 11.5 % and the measured MC parallel to grain direction was 11.3 %. The MC measured by dielectric type meter parallel to grain direction (12.1 %) was higher than that measured perpendicular to grain direction (10.7 %).

The moisture measurement of sintering material by the NIR simulator (근적외선 분광법을 이용한 simulator를 통한 소결원료 수분측정)

  • 이진우;정재인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1273-1275
    • /
    • 1996
  • Moisture measurements of s intering materials were performed using the simulator which can simulate various conditions taking place at the belt-conveyor of sintering process. The moisture sensor used in this experiment is NIR moisture meter(JE-330, KETT Electric Lab.). Using the simulator, we measured the moisture contents of sintering materials at different conditions. We found that the moisture content decreased as the rotation speed increased and the size of the sintering materials became smaller.

  • PDF

Estimation of Wood Oven-Dry Density by Using a Portable Dielectric Moisture Meter (휴대용 유전율식 수분계를 이용한 목재의 전건밀도 추정)

  • Kang, Chun-Won;Lim, Ho-Mook;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.629-639
    • /
    • 2017
  • Tripitaka Koreana in Haein Temple, Hapcheon Province is the most historical and largest heritage in this country, however the species of their blocks have yet been unknown. A nondestructive test method is necessary to investigate their species. The oven-dry density of wood was measured by inversely using the principle of high frequency moisture meter. The oven-dry densities of more than 100 domestic species of specimens estimated by measurement method and high frequency moisture meter were compared and following conclusions were obtained. There was highly close correlation between the oven-dry density estimated by measurement method and the oven-dry density estimated by high frequency moisture meter. The densities of Tripitaka Koreana that was a global cultural heritage could be correctly estimated by using high frequency moisture meter and the equilibrium moisture content under which Tripitaka Koreana equilibrated, thus, it was expected to provide the key to species identification.

Development of Correction Equation and Characteristics Evaluation for Moisture Meter of Microwave Resistance Type (고주파 저항방식 함수율계의 보정식 개발 및 특성평가)

  • Jeon, Hong-Young;Kang, Tae-Hwann;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.35 no.3
    • /
    • pp.175-181
    • /
    • 2010
  • This study compared moisture content measured by moisture meter of microwave resistance type(MMMRT) and standard moisture content of paddy, and developed the correction equation using linear and curvilinear regression analysis, and to explore its significance test. The correction factor according to the range of moisture content was developed to improve the measurement precision of MMMRT. The results were as followings. The coefficients of determination of correction equation by linear and curvilinear regression analysis with comparing the MMMRT and standard moisture content were 0.946 and 0.968, respectively. The moisture content error of MMMRT and standard moisture content measured after the MMMRT were corrected by moisture content rate of every 5% using the correction equation by curvilinear regression analysis appeared with 0~0.5% and 0.9~1.8% respectively in the moisture content range of 15~20% and 20~25%.

Correlation between Determining Values of Sectional Equilibrium Moisture Contents of Larix leptolepis and Populus euramericana I - 476 grown in Mt. Jiri (지리산산(智異山産) 일본 잎갈나무재(材)와 포플러재(材)의 단면별(斷面別) 평형함수율(平衡含水率)(EMC) 측정치(測定値)와 그 상관성(相關性))

  • Hwang, Jeung;Moon, Chang Kuck
    • Journal of Korean Society of Forest Science
    • /
    • v.59 no.1
    • /
    • pp.63-66
    • /
    • 1983
  • Sectional equilibrium moisture contents of Larix leptolepis and Populus euramericana I-476 were determined, their correlations and significances were investigated. Among the ovendry moisture contents. electric moisture meter determining values and the estimative values through chemical equilibria formula, there were significant correlations, 1-5% level, at whole sections in Larix leptolepis. However, in Populus euramericana there was only significant correlation between ovendry moisture content values and electric moisture meter determining values.

  • PDF

A Study on the Determination of Density and Moisture Content of Asphalt Concrete Pavement and Subgrade Using Nuclear Density Meter (방사선측정치를 이용한 아스콘 포장 및 노상의 현장밀도와 함수비 측정에 관한 연구)

  • 진성기;도덕현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.4
    • /
    • pp.103-116
    • /
    • 1994
  • The objective of this study was to determine the criteria for density and moisture content measurements made with a nuclear density meter on common materials in the construction field. The study also sought to test a full-type nuclear density meter in controlling the density of overlay layers( 2.5~5.0cm). In order to determine the accuracy and reliablility of nuclear guage measurements made on construction materials, laboratory and field tests were conducted. Wooden blocks( 65 x 45 ${\times}$ 50 cm) and a special steel compactor( 4.7kg) were constructed in order to carry out tests which were conducted on three different materials; coarse gramed soil, fine grained soil, and AC material. Throughout all laboratory and field tests, the nuclear density and moisture content were determined using Humboldt 5OOLP nuclear gauge. The tests on subgrade material entailed obtaining density measurements by means of both the sand replacement method and the nuclear density meter. The results of the sand replacement method were then compared to the readings recorded bu the meter. As in the subgrade material tests, density measurements made during AC pavement tests were also determined using the unclear meter in addition to a second means; through the core method. The meter readings and core densties were compared as was done in the tests on subgrade materials. The correlation between the results of the sand replacement test( also, the core method) and meter readings on subgrade material was then determined. Sirnilarly, the observed results were then analyzed through linear regression. The tests to determine thin-lift density by means of a full-type nuclear density meter also conducted on the overlay layers( about 4. 8cm thickness) above AC pavements at road construction sities in Korea.

  • PDF

Developement of Soil Moisture Meter using Capacitance Probe (정전용량 탐침을 이용한 토양수분 측정장치 개발)

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seung-Seok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.65-68
    • /
    • 2001
  • This study was conducted to develop a soil moisture meter using capacitance probe. A parallel cylinder type capacitance probe (C-probe) was fabricated The 5 MHz of crystal oscillator was constructed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model for volumetric water content having oscillation frequency changes at 5 MHz as independent variables presented the determination coefficient of 0.979 and root mean square error of $0.031\;cm^{3}cm^{3}$ for all soil samples. A prototype soil moisture meter consisting of the sample container, C-probe, oscillator, frequency counter and related signal procession units presented the correlation coefficient of 0.987 and the root mean square error of $0.032\;cm^{3}cm^{3}$ as compared with the oven drying method for unknown soil samples.

  • PDF

The effect of moisture on the efficiency of wet gas meter (수분이 습식 가스미터의 성능에 미치는 영향)

  • Jang, Seok;Yoon, Bok-Hyun;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.278-282
    • /
    • 2000
  • 상온 기체 유량 표준 시스템에서 물을 실링액으로 사용하는 습식 가스미터의 성능시험을 하였다. 습식 가스미터의 출구에서 습도를 측정하여 이를 보정에 사용하였다. 보정의 결과로 습식 가스미터가 가지고 있던 오차가 현저히 감축되는 것으로 보아 수분이 습식 가스미터의 성능에 지대한 영향을 미치는 것으로 본 실험에서 보여졌다. 이 결과로서 습식 가스미터의 성능 향상 및 국내 기술 개발에 유용한 데이터로 사용될 수 있을 것으로 기대된다.

  • PDF