• Title/Summary/Keyword: Moisture measurement

Search Result 561, Processing Time 0.026 seconds

Viscosity and Dynamic Rheological Properties of Job's-tears as a Function of Moisture Content (수분함량에 따른 율무가루의 점도변화 및 동적물성 특성에 관한 연구)

  • Yoon, Won-Byung;Kim, Byung-Yong;Shin, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.932-938
    • /
    • 1997
  • Changes in viscosity and dynamic theological properties of Job's-tears were measured by Bohlin dynamic tester as a function of moisture, and measurement was performed within a linear viscoelastic range. The result of the shear stress vs shear rate of Job's-tears at different moisture contents $(50{\sim}75%)$ was applied to mathematical models and Herschel-Bulkley model showed the highest correlation coefficient. Lower moisture content (55%) produced higher yield stress and consistency index, but lower flow behavior index, whereas higher moisture content showed reverse effects. Job's-tears with $50{\sim}70%$ moisture contents showed a higher storage modulus (G') than loss modulus (G') at all frequencies, showing a higher concentrated polymer characteristics. However, higher moisture content (>75%) showed crossover point between G' and G', and frequency dependency. As the moisture content was increased, the amount of viscoelastic properties such as G', G', complex viscosity decreased during heating, and initial temperature and miximum value of viscoelastic properties shifted to higher temperatures, representing the moisture-dependence of Job's-tears upon theological properties.

  • PDF

A simple practical method for determination of moisture transfer coefficient of mature concrete using a combined experimental-numerical approach

  • Chari, Mehdi Nemati;Shekarchi, Mohammad;Ghods, Pouria;Moradian, Masoud
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.367-388
    • /
    • 2016
  • In this paper, a simple practical method is introduced in which a simple weight measurement of concrete and finite element numerical analysis are used to determine the moisture transfer coefficient of concrete with a satisfactory accuracy. Six concrete mixtures with different water-to-cementitious material (w/cm) ratios and two pozzolanic materials including silica fume and zeolite were examined to validate the proposed method. The comparison between the distribution of the moisture content obtained from the model and the one from the experimental data during both the wetting and drying process properly validated the performance of the method.With the proposed method, it was also shown that the concrete moisture transfer coefficient considerably depends on the pore water saturation degree. The use of pozzolanic materials and also lowering w/cm ratio increased the moisture transfer coefficient during the initial sorption, and then, it significantly decreased with an increase in the water saturation degree.

Computational Analysis of the Heat/Moisture Characteristics and Heat Load of Underground Structures (열.수분 동시이동 모델을 이용한 지하구조물 및 주변지반의 열수분성상 예측에 관한 연구)

  • Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.901-905
    • /
    • 2008
  • This study was conducted to clarify the heat load characteristics and heat and moisture behavior of underground structures. The authors achieved this by carrying out a numerical analysis using simple heat diffusion and simultaneous heat and moisture transfer equations based on measurement data. This paper presents the results of a numerical analysis on the heat load characteristics and heat and moisture behavior of an underground basement and its surrounding ground under a condition of internal heat generation. The authors found it difficult to predict the heat behavior and heat load of the underground basement by simple heat diffusion alone. Accurate prediction of the thermal environment and heat load requires careful consideration of the influences of moisture and precipitation

  • PDF

NEAR INFRARED SPECTROSCOPY, A POWERFUL TECHNIQUE IN HUMAN SKIN STUDY : PART I METHOD RELIABILITY AND INFLUENTIAL PARAMETERS

  • Snieder, Marchel;Wiedemann, Sophie;Hansen, Wei G.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3101-3101
    • /
    • 2001
  • Near Infrared spectroscopy (NIR) used on human skin measurement was explored in the past decade. Many publications in different journals and magazines discussed the feasibility of the NIR technique for cosmetic product property studies. Based upon the results of pioneers, we have pursued some work of the NIR instrument coupled with a probe module for skin measurement in vivo and vitro. In part I of this paper, the specific Near Infrared spectroscopy instrument stability, human subject conditions and other parameters, which could affect the measurements reproducibility are discussed. Second derivative NIR spectra and Principle Components Analysis (PCA) are utilised for data interpretation. In part II of this paper, the relationship of human skin moisture and ageing, the gender information and finally, the discovery of penetration depth of NIR incident light on skin are reported. A theoretical penetration depth calculation equation is proposed. In part III, the study results of a couple of commercial skin care products effect will be described. The skin lotions were applied on human skin (in vivo) in order to exam the NIR feasibility to monitor the changes of moisture level. The results are consistently positive. From our primary study, it can conclude that the NIR is potentially a very powerful instrument for skin condition diagnostics, either for cosmetic and/or for medication purposes.

  • PDF

Comparative Experimental Study on the Evaluation of the Unit-water Content of Mortar According to the Structure of the Deep Learning Model (딥러닝 모델 구조에 따른 모르타르의 단위수량 평가에 대한 비교 실험 연구)

  • Cho, Yang-Je;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.8-9
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data. The multi-input deep learning model is as accurate as 24.25% higher than the OLS linear regression model, which shows that deep learning can more effectively identify the nonlinear relationship between high-frequency moisture sensor data and unit quantity than linear regression.

  • PDF

Numerical Analysis and Experimental Measurement of Hygroscopic Warping Effects for Cellulose Fibres (셀룰로스 복합소재에서의 수분에 의한 뒤틀림 변형효과를 위한 수치해석적 실험적 연구)

  • Kim, Byeong-Sam;Kim, Ki-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.117-123
    • /
    • 2004
  • The prediction to the hydroscopic moisture warping behaviors is analyzed for cellulose-based laminates using a numerical method base on a modified classical laminate(MCL) theory for hygroscopic moisture deformations with cycling testing data. The experimental measurement of the interferometric hygroscopic warping effects, moisture generator, and curvature of cellulose reinforced epoxy laminates is studied under cyclic environmental conditions using a Moire interferometer coupled. Accurate determination of curvatures provides a description of dimensional stability evolution; the tools for validation of computational internal stress and for the warpage prediction in model safety.

Estimation of High-Resolution Soil Moisture Using Sentinel-1A/B SAR and Soil Moisture Data Assimilation Scheme (Sentinel-1A/B SAR와 토양수분자료동화기법을 이용한 고해상도 토양수분 산정)

  • Kim, Sangwoo;Lee, Taehwa;Chun, Beomseok;Jung, Younghun;Jang, Won Seok;Sur, Chanyang;Shin, Yongchul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.11-20
    • /
    • 2020
  • We estimated the spatio-temporally distributed soil moisture using Sentinel-1A/B SAR (Synthetic Aperture Radar) sensor images and soil moisture data assimilation technique in South Korea. Soil moisture data assimilation technique can extract the hydraulic parameters of soils using observed soil moisture and GA (Genetic Algorithm). The SWAP (Soil Water Atmosphere Plant) model associated with a soil moisture assimilation technique simulates the soil moisture using the soil hydraulic parameters and meteorological data as input data. The soil moisture based on Sentinel-1A/B was validated and evaluated using the pearson correlation and RMSE (Root Mean Square Error) analysis between estimated soil moisture and TDR soil moisture. The soil moisture data assimilation technique derived the soil hydraulic parameters using Sentinel-1A/B based soil moisture images, ASOS (Automated Synoptic Observing System) weather data and TRMM (Tropical Rainfall Measuring Mission)/GPM (Global Precipitation Measurement) rainfall data. The derived soil hydrological parameters as the input data to SWAP were used to simulate the daily soil moisture values at the spatial domain from 2001 to 2018 using the TRMM/GPM satellite rainfall data. Overall, the simulated soil moisture estimates matched well with the TDR measurements and Sentinel-1A/B based soil moisture under various land surface conditions (bare soil, crop, forest, and urban).

Experimental on the Accuracy of Soil Water Content Measurement Using TDR (TDR을 이용한 토양함수비 측정의 정확성에 대한 실험)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.86-96
    • /
    • 1999
  • Laboratory experiment was performed for the TDR to measure the soil moisture, and the results, were compared with the design water content and the one measured by oven-try method. Sand and kaolinite were used . Varaiables for the experiment were water content (10-50%), void ration (0.7 -1.3), mixture rate of kaolinite (10-30%), and measurement methods (TDR and oven-dry). In all cases , TDR method showed very accurage and reliable results , and average error and error range were far lews than the oven-dry method which is widely used. Considerable error was noticed when water contnet was 50% where saturation was achieved for both methods. Therefore, TDR was thought to be applicable to the field moisture measurement if it is unsaturated. For field scale application of TDR, more research and verification of the accuracy with diverse soil conditions including physical ,chemical and mineral properties are recommended.

  • PDF

Effects of Chogam-Tang on Rat Skin Induced the Allergic Contact Dermatitis (백서(白鼠)에 유도된 알러지성 피부염에 대한 초감탕(椒甘湯)의 효과)

  • Yoon, Hui-Sung;Park, Owe-Suk;Kim, Hee-Jeong;Kim, Keoo-Seok;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.18 no.3
    • /
    • pp.44-54
    • /
    • 2005
  • Background and Objectives: Allergic contact dermatitis is a common environmental health issue and seriously affect the patient's quality of life. The more our environment industrialized, the number of material that could cause the allergic contact dermatitis has been increased, consequently the prevalence of allergic contact dermatitis has been increased. In oriental medicine, clinically Chogam-Tang has been used fur the treatment of allergic dermatitis, eczema, atopic dermatitis etc. The objective of this study is to investigate the effects of Chogam-Tang on allergic contact dermatitis Meterial and Methods: Fifteen Sprague-Dawley rats were divided into three groups: normal, control, experimental group. Control and experimental group were induced allergic contact dermatitis, by DNCB. Experimental group was orally administered the Chogam-Tang. Each group was observed after 24, 48 and 72 hours. Contact hypersensitivity assay, melanin-erythema measurement, pH measurement skin moisture measurement and biopsy were performed. Results: 1. In contact hypersensitivity assay, experimental group showed decreased ear swelling compared with control group at 48hours. 2. ln melanin measurement there was no difference in three groups. 3. In erythema measurement experimental group showed reduction at 48. 72 hours. 4. In pH measurement, experimental group and control group showed increase in pH but there was no statistical significance. 5. In skin moisture measurement, experimental group showed higher skin moisture level than control group at 24 hours and showed lower skin moisture level at 72 hours, but there was no statistical significance. 6. In biopsy, experimental group showed decrement of Iymphocyte as time goes by, and regeneration of keratin layer was increased compared with normal group. Conclusions: Chogam-Tang shows anti-inflammatory effect in biopsy, improves hydration levels of skin, decreases erythema level on allergic contact dermatitis.

  • PDF

Condition of Facial Skin by Non-invasive Measurement and Lipid.Moisture Type of the Facial Ski by Subjective Self-consciousness in Some Middle-aged Women (중년여성의 자각하는 유.수분 유형과 비침습적 방법으로 측정한 안면피부상태)

  • Kang, Soo-Kyung;Ryu, So-Yeon;Park, Jong
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.279-283
    • /
    • 2005
  • The content of lipid or moisture and index of erythema or melanin on each facial part of 170 urban middle-aged women without dermic disease was measured by non-invasive method. This measurement intended to understand the skin condition on each facial part of middle-aged women, and to determine the correlation between objective measured values and subjective symptom of lipid content/moisture content. The results was summarized as follows. At each facial Part, the order of moisture content was eye rims, forehead, and cheek and that of lipid content was forehead, eye rims, and cheek. The erythema index was in the order oi forehead, cheek and eye rims and melanin index, in the order of eye rims, forehead and cheek. It turned out that the middle-aged women generally lacked lipid content rather than moisture one. The objective measured values of lipid content coincided with subjective symptom of lipid type. The lipid content, erythema index and melanin index showed correlation significantly.