• Title/Summary/Keyword: Moist Air Density

Search Result 7, Processing Time 0.022 seconds

Moist Air Density Calculation for Air Condition (공기 상태량에 대한 습공기 밀도 계산)

  • Kim, Jong-Woo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.105-111
    • /
    • 2014
  • Generally the lower part of the Earth's atmosphere, which is 20km above the ground, is called "air." The composition of this area is almost consistent consisting of nitrogen, oxygen, and other gases. Air density refers to the mass per unit volume of earth atmosphere. Though air is made of the mixed gases in a constant composition, the water vapor is one of the very changeable components. The density of moist air is lower than the dry one at the same temperature and pressure. As the density varies according to the pressure and temperature, this paper attempts to explore the main factors in the air quantity calculation by examining first the density calculation process according to the air property, and second the relation between the actual and standard air flow.

The Unsteady Cavity Flow Oscillation in Supersonic Moisture Air Stream (초음속 습공기 유동에서 비정상 공동유동의 진동)

  • Shin, Choon-Sik;Lee, Jong-Sung;Kim, Heuy-Dong;Setoguchi, Toshiaki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.341-344
    • /
    • 2008
  • Numerical simulations have been carried out for a supersonic two-dimensional flow over open, rectangular cavities (length-to-depth ratios are L/D = 1.0) in order to investigate the effect of non-equilibrium condensation of moist air on supersonic flows around the cavity for the flow Mach number 1.83 at the cavity entrance. In the present computational investigation, a condensing flow was produced by an expansion of moist air in a Laval nozzle. The results obtained showed that in the case with non-equilibrium condensation for L/D = 1.0, amplitudes of oscillation in the cavity became smaller than those without the non-equilibrium condensation. Furthermore, the occurrence of the non-equilibrium condensation reduced the peaks of power spectrum density and the frequency of the flow field oscillation increased in comparison with the case of $S_0$ = 0.

  • PDF

Modeling for Frost Growth on a Cold Plate (냉각 평판에서 서리 성장 모델링)

  • Yang, Dong-Keun;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1546-1551
    • /
    • 2004
  • This paper presents a mathematical model to predict the frost properties and heal and mass transfer within the frost layer formed on a cold plate. The laminar flow equations for the air-side are analyzed. and the empirical correlations of local frost properties are employed in order to predict the frost layer growth. The correlations of local frost density and effective thermal conductivity of frost layer, obtained from various experimental conditions, are derived as functions of various frosting parameters (Reynolds number, frost surface temperature, absolute humidity and temperature of moist air, cooling plate temperature, and frost density). The numerical results are compared with experimental data and the results of various models to validate the present model, and agree well with experimental data within a maximum error of 10%. The heat and mass transfer coefficients obtained from the numerical analyses are presented, as the results, it is found that the model for frost growth using the correlation of heat transfer coefficient without solving air flow have a limitation in its application.

  • PDF

Drawing of Twenty Kinds of State and Process on Psychrometric Chart (습공기선도 상에 20 종류의 상태 및 과정 값의 작도)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

Comparison of Sampling Methods for On-Farm Use Quick Test Procedure of Soil Nitrate (토양의 질산태질소 현장검정을 위한 시료 채취방법 비교)

  • Kang, Seong-Soo;Kim, Ki-In;Chung, Keun-Yook;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.1
    • /
    • pp.32-37
    • /
    • 2005
  • The procedure of soil sampling for on-farm quick test of soil nitrate is very important to improve practical application without weighing or drying soil. To improve application of test strip reflectometer as a quick on-farm analytical procedure for the estimation of soil nitrate concentration, three sampling methods such as gravimetric sampling (GS), particle density sampling (PDS) and bulk density sampling (BDS) for on-farm analytical procedure were investigated with twelve soils of 45 to $281mg\;kg^{-1}$ nitrate nitrogen concentration. The nitrate nitrogen concentrations measured from different soils were compared with two analytical methods, ion electrode method as a standard laboratory analysis (SLA) and test strip reflectometer at three moisture conditions, viz. air dried soil, 20 and 40% of maximum water holding capacity (MWHC). Nitrate nitrogen concentration measured by test strip reflectometer was significantly correlated with that of SLA, and the coefficients of variation (CV) were in the range of 3.5 to 10.9%. These CV values less than 10.9% were thought to be acceptable for the measurement of soil nitrate as an on-farm real time analytical procedure. The nitrate nitrogen concentration by BDS for test strip reflectometer as well as ion electrode method was more similar to that of SLA compared with those by GS and PDS especially in case of moist soils. This result suggests that the BDS is more useful than GS and PDS in case of on-farm analytical procedure of soil nitrate for moist soils. Further the practical measurement by BDS could be improved by substituting the bottle cap with a larger container.

Taxonomical Classification of Namweon Series, Black Volcanic Ash Soils (흑색 화산회토인 남원통의 분류)

  • Song, Kwan-Cheol;Hyun, Byung-Geun;Sonn, Yeon-Kyu;Lim, Han-Cheol;Lee, Shin-Chan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.385-392
    • /
    • 2009
  • This study was conducted to reclassify Namweon series, black volcanic ash soils, in Jeju Island based on the second edition of Soil Taxonomy : A Basic System of Soil Classification for Making and Interpreting Soil Surveys. Morphological properties of typifying pedon of Namweon series were investigated and physicochemical properties were analyzed according to Soil Survey Laboratory Methods Manual. The typifying pedon of Namweon series has black (10YR 2/1) silt loam Ap horizon (0~11 cm) and black (10YR 2/1) silt loam BA horizon (11~72 cm). Bw horizon (72~100 cm) is very dark brown (10YR 2/2) silt loam. That occurs on lava plain derived from volcanic ash materials. The typifying pedon contains 5.2~6.4% oxalate extractable (Al + 1/2 Fe), over 85% phosphate retention, and lower bulk density than $0.90Mg\;m^{-3}$. Ap, BA, and Bw horizons of the pedon have andic soil properties. That can be classified as Andisol. The typifying pedon has an udic soil moisture regime and has a 1,500 kPa water retention of 15% or more on air-dried samples throughout all horizons, and can be classified as Udand. Ap and BA horizons (0~72 cm) have a color value, moist, and chroma of 2 or less, melanic index of 1.70 or less, and 6% or more organic carbon. That meets the requirements of melanic epipedon. That keys out as Melanudand. That has more than 6.0% organic carbon and the colors of mollic epipedon throughout a layer 50 cm or more thick within 60 cm of the mineral soil surface.. Thus, that keys out as Pachic Melanudand. The pedon has a fine-earth fraction that has a water content at 1,500 kPa tension of 12% or more on air-dried samples and has less than 35% (by volume) rock fragments. Thus, the substitute for particle-size class is medial. That has a sum of 8 times the Si (percnt by weight extracted by acid oxalate) plus 2 times the Fe (percnt by weight extracted by acid oxalate) of 5 or more, and 2 times the Fe is more than 8 times the Si. Thus, the mineralogy class is ferrihydritic. Namweon series can be classified as medial, ferrihydritic, thermic family of Pachic Melanudands, not as ashy, thermic family of Typic Melanudands.