• Title/Summary/Keyword: Moire Method

Search Result 138, Processing Time 0.027 seconds

The strain measurement on the aluminum alloy welded transition joint (알루미늄 合金 異材熔接部의 變形率測定)

  • 옹장우;전제춘;오상진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.625-634
    • /
    • 1986
  • The strain distribution on a welded aluminum alloy transition joint produced by a static tensile load has been measured using a moire method combined with photoelastic coating method. The test specimens were made of aluminum alloy 6061-T6 and 2014-T6 butt welded with ER-4043 filler metal, and were post welded heat treated (solid solution heat treatment 502.deg. C 70min.) and precipitated (artificial aging 171.deg. C 600min.) to cause an abrupt change of mechanical properties between the base metals and weld metal. The photoelastic epoxy rubber was cemented on the specimen grating which had been reproduced on the specimen surface by using an electropolishing. The measurements were compared with strains computed by Finite Element Analysis. The following results were abtained. (1) The maximum strain were distributed along the center line in the transverse directiion of the weld metal. (2) The strain gradient along the fusion line increased approaching the V-groove tip and the maximum value was observed at a quarter of width from the V-groove tip. (3) The moire method combined with photoelastic coating was proved very useful for real time strain measurement in the welded aluminum alloy transition joint.

Moire' Free Pseudo-Random Method in Digital Halftoning (무아레 억제용 의사 랜덤 망점화)

  • 박희윤
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.15 no.2
    • /
    • pp.91-106
    • /
    • 1997
  • The new algorithm for halftone generation for gravure engraving was developed. The basic concept of this algorithm is based on the mapping and equal density expansion methods that we are mapped out. The program was used by the Microsoft Visiul C++2.0 and could be loaded in IBM personal computer.

  • PDF

Clothing-Ergonomics Study on the Development of Slacks Pattern and Wearing Evaluation for the Middle-high School Girls Based on the their Lower Body Type (여중생의 하반신 유형별 슬랙스 원형설계 및 착의평가에 관한 피복인간공학적 연구)

  • 임지영;김혜경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.8
    • /
    • pp.1125-1136
    • /
    • 2000
  • Fitness of clothes becomes a major concern in apparel industry. Development of basic patterns will enhance the fitness of clothes. But there are few slacks patterns for the middle-high school girls. So girls had difficulties to buy ready-made clothes of good fit. To solve this problem, it is necessary to develop basic slacks patterns. The purposes of this study was to develop basic slacks patterns based on the analysis of lower body types. 4 girls were selected among 402 anthropometric measurement subjects who are 13 to 15 year-old for the wearing tests. The result of this study can be summarized as follows; 1. Analysing the replicas of lower body surface by using gypsum method, slack patterns were developed. 2. Wearing test by the sensory evaluation showed that the developed slacks pattern was estimated more highly than existing patterns in the items of the comfort of front crotch and back crotch. 3. Wearing test by moire topography method represented that garment silhouette of developed slacks pattern was estimated more highly and garment space of waist, hip were significantly different among patterns.

  • PDF

Numerical Analysis and Experimental Measurement of Hygroscopic Warping Effects for Cellulose Fibres (셀룰로스 복합소재에서의 수분에 의한 뒤틀림 변형효과를 위한 수치해석적 실험적 연구)

  • Kim, Byeong-Sam;Kim, Ki-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.117-123
    • /
    • 2004
  • The prediction to the hydroscopic moisture warping behaviors is analyzed for cellulose-based laminates using a numerical method base on a modified classical laminate(MCL) theory for hygroscopic moisture deformations with cycling testing data. The experimental measurement of the interferometric hygroscopic warping effects, moisture generator, and curvature of cellulose reinforced epoxy laminates is studied under cyclic environmental conditions using a Moire interferometer coupled. Accurate determination of curvatures provides a description of dimensional stability evolution; the tools for validation of computational internal stress and for the warpage prediction in model safety.

Study on Deformation and Strength of Fillet Welds (Fillet Welding Joint의 파괴기구(破壞機構)와 강도(强度)에 관한 연구(硏究))

  • Dong-Suk,Um
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.7 no.2
    • /
    • pp.27-40
    • /
    • 1970
  • The distribution of stress and strain in elastic stages is investigated by the experiments of two dimensional photoelastic coating and Moire fringe method. Center block type and cover plate type of fillet welds are used as specimens in the test. The results are as follows. 1) Center block type gets less uniform stress distribution than cover plate type. And its stress concentration factor, especially at root, is larger than that at toe. 2) When main plate and cover plate closely contact and it cause friction, stress concentration decreases more than that in case of slit. That is because stress can be transmitted on the contact surface. 3) When slit is made, the outside of fillet gets more stress than the inside of it. 4) While the plastic strain distribution of center block type reaches the maximum at root and differs very slightly from that under lower loading, the plastic strain distribution of cover plate type is inclined to get the maximum at the outside of fillet rather than at root. 5) When the plastic strain value of cover plate type is compared with that of center block type at toe and root, the relations between the former and the latter shows root<toe and root>toe. 6) Because stress distribution becomes changed according to loading, fracture angle cannot be estimated by the peaks of elastic stress distribution. 7) The strain distribution just before fracture can be found by Moire fringe method.

  • PDF

A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image (노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법)

  • Kim, Kuk-Won;Kim, Min-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.909-916
    • /
    • 2009
  • This paper presents the automatic vision algorithm to generate and calibrate reference phase plane to improve the accuracy of 3D measuring machine of using phase shifting projection moire method, which is not traditional N-bucket method, but is based on direct image processing method to the pattern projection image. Generally, to acquire accurate reference phase plane, the calibration specimen with well treated surface is needed, and detailed calibration method should be performed. For the cost reduction of specimen manufacturing and the calibration time reduction, on the specimen, not specially designed, with general accuracy level, an efficient calibration procedure for the reference phase generation is proposed. The proposed vision algorithm is developed to extract the line center points of the projected line pattern from acquired images, derive the line feature information consisting of its slope and intercept by using sampled feature points, and finally generate the related reference phase between line pairs. Experimental results show that the proposed method make reference phase plane with a good accuracy under noisy environment and the proposed algorithm can reduce the total cost to make high accurate calibration specimen, also increase the accuracy of reference phase plane, and reduce the complex calibration procedure to move grid via N-bucket algorithm precisely.

A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image (Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구)

  • Lee Eun-Kyoung;Yu Seung-Hyun;Lee Su-Kyung;Kang Sung-Ho;Han Jong-Min;Chong Myong-Soo;Chun Eun-Joo;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF