• Title/Summary/Keyword: Module Temperature

Search Result 1,225, Processing Time 0.028 seconds

Evaluation on Calculation Algorithms for Polycrystalline Silicon PV Module Surface Temperatures by Varying External Factors during the Summer Period (다결정 실리콘 PV모듈의 하절기 표면온도 예측을 위한 알고리즘 검토 및 외부인자별 영향 평가)

  • Jung, Dong-Eun;Yeom, Gyuhwan;Lee, Chanuk;Do, Sung-Lok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.177-184
    • /
    • 2019
  • Recently, electric power usages and peak loads from buildings are increasing due to higher outdoor air temperatures and/or abnormal climate during the summer period. As one of the eco-friendly measures, a renewable energy system has been received much attention. Particularly, interest on a photovoltaic (PV) system using solar energy has been rapidly increasing in a building sector due to its broad applicability. In using the PV system, one of important factors is the PV efficiency. The normal PV efficiency is determined based on the STC(Standard Test Condition) and the NOCT(Nominal Operating Cell Temperature) performance test. However, the actual PV efficiency is affected by the temperature change at the module surface. Especially, higher module temperatures generally reduce the PV efficiency, and it leads to less power generation from the PV system. Therefore, the analysis of the relation between the module temperature and PV efficiency is required to evaluate the PV performance during the summer period. This study investigates existing algorithms for calculating module surface temperatures and analyzes resultant errors with the algorithms by comparing the measured module temperatures.

Implementation of Temperature and Humidity Sensor Module Based on Z-wave (Z-Wave 기반의 온습도 센서 모듈 구현)

  • Weon, La kyoung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.4
    • /
    • pp.157-166
    • /
    • 2022
  • The most commonly used wireless communication technologies in IoT technology include ZigBee, WiFi, Bluetooth, and Z-Wave. In particular, Z-Wave is currently one of the preferred wireless communication technologies, with a global market share of 60 % of these technologies. In this research, a temperature and humidity sensor module using a Z-wave protocol was designed and manufactured by referring to the data sheet. Subsequently, the Z-Wave protocol was analyzed during the operation of the sensor module, and the firmware of the controller module was mounted and implemented. In addition, a program for monitoring the temperature and humidity information from the sensor module was developed and validated. Finally, the performance of the sensor module was validated through master distance and low power tests on it and its reception data success rate.

A dust continuum radiative transfer module

  • Lee, Seokho;Lee, Jeong-Eun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.55.1-55.1
    • /
    • 2016
  • We have developed a module for the dust continuum radiative transfer calculation as part of "Packages of Unified modeling for Radiative transfer, gas Energetics, and Chemistry (PUREC)". PUREC will be applied to interprete observations of protoplanetary disks. When a disk is under the hydrostatic equilibrium condition, the dust temperature and the vertical density structure should be calculated simultaneously. This module calculates the dust temperature by using the method of mean intensity (Lucy et al. 1999). In the very optically thick mid-palne, the Monte-carlo method is not efficient, thus, we apply "modified random walk" and "Partial Diffusion Approximation" to the module. The module has been verified by bechmark tests.

  • PDF

Performance test of PVT-water system considering ambient air and circulating water temperature (외기 및 순환수 온도조건을 고려한 PVT-water 시스템의 성능실험)

  • Jeong, Yong-Dae;Nam, Yujin
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.83-88
    • /
    • 2015
  • Purpose: Photovoltaic system is a technique for producing electrical power by utilizing solar energy, which can be used over 20 years with simple maintenance. However, in the case of photovoltaic systems, the energy conversion efficiency decreases as the surface temperature of module increases, compared with other renewable energy technologies. In this regard, PVT module can increase the energy utilization of a composite module as producing heat and electricity simultaneously by using solar energy. Currently, many researches have been promoting in order to develop a high efficiency PVT module in Korea. However, there are a few studies about the performance of the modules corresponding the shape of types and various heat exchangers of the PVT module. In this study, the electrical performance was measured by the change of the ambient temperature and the circulating water temperature using the fabricated PVT module. Method: Experiments were performed using a solar simulator. And this experiment was assumed that the weather condition was in each season, as winter, spring, autumn and summer. It was identified that the I-V curve associated with the change of the experimental conditions and confirmed the change in the electrical characteristics. Result: As a result, it was figured out that the surface temperature and the electrical performance changes in case conditions. The electrical performance was calculated in different temperature condition and the power production was confirmed by the change of module temperature.

An experimental study on cooling characteristic of a thermoelectric module (열전모듈의 냉각특성에 관한 실험적 연구)

  • Hwang, Jun;Kang, Byung Ha
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.4
    • /
    • pp.341-347
    • /
    • 2004
  • An experimental study has been carried out on cooling perfonnance of a thennoelectric module. This problem is of particular interest in the design of the refrigeration systems using thermoelectric module, such as cosmetic refrigerator, wine cellar and air cooler. The effect of the input voltage and the hot side temperature on the cooling performance is studied in detail. The $\Delta$T, temperature difference between cold side and hot side surface of thermoelectric module, is described in terms of the input voltage and the hot side temperature. It is found that the cooling capacity can be improved by increasing the input voltage and by reducing the heat from the hot side of the thermoelectric module. However, COP is decreased with an increase in the input voltage, since power consumption is also increased. Thus, optimum input voltage can be selected based on cooling capacity and COP.

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack (흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구)

  • Park, Sang-Hui;Sin, Dae-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

A study on the temperature difference of module's front and back (태양전지 전.후면의 온도차에 관한연구)

  • Shin, Hye-Young;Choi, Hong-Kyoo;Lee, Guen-Moo;Choi, Kyung-Han
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.55-58
    • /
    • 2009
  • Photovoltaic system that is overcoming the problem of fossil fuel, changes the output quantity rapidly according to the temperature of module. so, we studied this principle and considered the method making lower the temperature of module for maximization of electric power production. In this thesis, we concluded that, we fit on below and upper direction of the module to decrease at the same temperature. lower temperature of below direction is more useful for the generating quantity.

  • PDF

Analysis of Temperature and Generation Characteristics of Semi-transparent Module (건물일체형 반투명 태양광발전모듈의 후면 유리 종류에 따른 온도 및 발전 특성 분석)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1106-1107
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. It reports the effect of thermal characteristics of the PV module on generation performance. The study was performed by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

PIV Measurement of Flow Inside an Automotive HVAC Module with Varying Temperature Baffle (온도조절 격판 변화에 따른 차량용 HVAC 내부 유동의 PIV속도장 측정 연구)

  • Ji, Ho-Seong;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • Air flow inside an automotive HVAC module has been investigated using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser (125 mJ), a high-resolution CCD camera (2K$\times$2K), optics and a synchronizer. A real automotive HVAC module was used directly under real operating condition. Some casing parts of the HVAC module were replaced with transparent windows for capturing clear flow images with laser light sheet beam illumination. Time-averaged velocity fields were obtained for two different temperature control modes. Flow characteristics of the air-conditioned air flow inside the automotive HVAC system for the two temperature baffle conditions were evaluated.