• Title/Summary/Keyword: Module Plants

Search Result 153, Processing Time 0.021 seconds

Modeling and Validation of Population Dynamics of the American Serpentine Leafminer (Liriomyza trifolii) Using Leaf Surface Temperatures of Greenhouses Cherry Tomatoes (방울토마토에서 잎 표면온도를 적용한 아메리카잎굴파리(Liriomyza trifolii) 개체군 밀도변동 모형작성 및 평가)

  • Park, Jung-Joon;Mo, Hyoung-Ho;Lee, Doo-Hyung;Shin, Key-Il;Cho, Ki-Jong
    • Korean journal of applied entomology
    • /
    • v.51 no.3
    • /
    • pp.235-243
    • /
    • 2012
  • Population dynamics of the American serpentine leafminer, Liriomyza trifolii (Burgess), were observed and modeled in order to compare the effects of air and tomato leaf temperatures inside a greenhouse using DYMEX model builder and simulator (pre-programed module based simulation programs developed by CSIRO, Australia). The DYMEX model simulator consisted of a series of modules with the parameters of temperature dependent development and oviposition models of L. trifolii were incorporated from pre-published data. Leaf surface temperatures of cherry tomato leaves (cv. 'Koko') were monitored according to three tomato plant positions (top, > 1.8 m above the ground level; middle, 0.9 - 1.2 m; bottom, 0.3 - 0.5 m) using an infrared temperature gun. Air temperature was monitored at the same three positions using a self-contained temperature logger. Data sets for the observed air temperature and average leaf surface temperatures were collected (top and bottom surfaces), and incorporated into the DYMEX simulator in order to compare the effects of air and leaf surface temperature on the population dynamics of L. trifolii. The initial population consisted of 50 eggs, which were laid by five female L. trifolii in early June. The number of L. trifolii larvae was counted by visual inspection of the tomato plants in order to verify the performance of DYMEX simulation. The egg, pupa, and adult stage of L. trifolii could not be counted due to its infeasible of visual inspection. A significant positive correlation between the observed and the predicted numbers of larvae was found when the leaf surface temperatures were incorporated into the DYMEX simulation (r = 0.97, p < 0.01), but no significant positive correlation was observed with air temperatures(r = 0.40, p = 0.18). This study demonstrated that the population dynamics of L. trifolii was affected greatly by the leaf temperatures, though to little discernible degree by the air temperatures, and thus the leaf surface temperature should be for a consideration in the management of L. trifolii within cherry tomato greenhouses.

Effects of Planting Soil on the Soil Moisture and the Growth of Vitex rotundifolia for Green Roof (옥상녹화 식재지반이 토양수분과 순비기나무의 생육에 미치는 영향)

  • Park, Jun-Suk;Park, Je-Hea;Ju, Jin-Hee;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.3
    • /
    • pp.98-106
    • /
    • 2010
  • This study focuses on the appropriate planting soil for Vitex rotundifolia by planting soil. Different soil depth levels were achieved at 15cm and 25cm in the green roof module system that was created with woody materials for a $500{\times}500{\times}300mm$ area. The soil mixture ratio was $S_{10}$, $L_{10}$, $S_7L_3$, $S_5L_5$, $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$ and $P_4P_4L_2$. This study was carried out over five months between April and September, 2006. The amount of soil moisture tends to decrease according to the planting soil. For the experimental items $S_{10}$, $S_7L_3$ and $S_5L_5$, the amount of soil moisture tends to decrease rapidly. However, for the experimental items $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$ and $P_4P_4L_2$, conditions containing perlite and peat moss, the amount of moisture tends to decrease more gradually. As a result, the use of soil-improving amending for the afforestation planting of roofs with a low level of management is need. After experimenting with the ratio of soil mixture for Vitex rotundifolia, the planting soil for experimental item $P_6P_2L_2$, $P_5P_3L_2$ and $P_4P_4L_2$ appeared excellent. For experimental item $S_{10}$, the growth of Vitex rotundifolia seemed to be weaker than that of others, because of the low levels of moisture and organic matter in the soil. For experimental item $L_{10}$, there appeared to be a low level of growth, even when the levels of moisture and organic matter were high. This may have occurred because of the low level of soil pH and the excessive amount of exchangeable cation. At the depth of 25cm, the growth of Vitex rotundifolia is vigorous overall. For experimental item at 15cm, Vitex rotundifolia was able to survive for 14 days without any rainfall and Vitex rotundifolia was better in amended soil, $P_6P_2L_2$, $P_5P_3L_2$ and $P_4P_4L_2$, than natural soil, SL.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.