• Title/Summary/Keyword: Modulation Transfer Function

Search Result 289, Processing Time 0.026 seconds

Flame Transfer Function Modeling in a Gas Turbine Partially-premixed Combustor with Equivalence Ratio Modulation (가스터빈 부분 예혼합 연소기에서 당량비 섭동에 대한 화염전달함수 모델링)

  • Kim, Jihwan;Kim, Daesik
    • Journal of ILASS-Korea
    • /
    • v.22 no.2
    • /
    • pp.55-61
    • /
    • 2017
  • This study has investigated the relationship between heat release fluctuations and the flow perturbations in a partially premixed gas turbine combustor using a commercial CFD code. Special focus of the current work is placed on the effect of equivalence ratio on the flame dynamics in a partially-premixed system. As the first step for this combustion dynamics study in the non-perfectly premixed combustor, flame behaviors are modeled and then compared with measured results under both steady and unsteady conditions. The calculated results of the flame transfer function with equivalence ratio fluctuation are found to well capture the main qualitative characteristics of the combustion dynamics for the partially-premixed flames.

Spatial Frequency Filtering Characteristics of Annular Phase Gratings (고리형 위상 격자의 공간 주파수 필터 효과)

  • 김인길;고춘수;임성우;오용호;이재철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.994-1000
    • /
    • 2004
  • We studied the characteristics of annular phase gratings as spatial frequency filters. We first calculated the Fraunhofer diffraction patterns of annular gratings and then got the modulation transfer function (MTF) from the zeroth order Hankel transform of the intensity distribution function. Binaryphase annular grating shows higher diffraction efficiency than binary phase rectangular grating. But the MTF decreases linearly in the low-frequency region as that of rectangular grating does. The diffraction pattern of 4-phase annular grating is similar to that of 2-phase grating and hence MTFs of the two are much alike. For 8-phase annular grating, the 7th order diffracted beam is the lowest one next to the first. Consequently, the diffraction efficiency is very high and the MTF graph is curved upward. The diffracted beams except the first order are negligible and hence the MTF characteristics are more improved in the case of 16-phase grating. But the degree of improvement becomes lowered c(Impaled with 8-phase grating. We made a 16-phase annular grating and measured its MTF. The experimental result agrees well with the calculated one.

MULTI-APERTURE IMAGE PROCESSING USING DEEP LEARNING

  • GEONHO HWANG;CHANG HOON SONG;TAE KYUNG LEE;HOJUN NA;MYUNGJOO KANG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.27 no.1
    • /
    • pp.56-74
    • /
    • 2023
  • In order to obtain practical and high-quality satellite images containing high-frequency components, a large aperture optical system is required, which has a limitation in that it greatly increases the payload weight. As an attempt to overcome the problem, many multi-aperture optical systems have been proposed, but in many cases, these optical systems do not include high-frequency components in all directions, and making such an high-quality image is an ill-posed problem. In this paper, we use deep learning to overcome the limitation. A deep learning model receives low-quality images as input, estimates the Point Spread Function, PSF, and combines them to output a single high-quality image. We model images obtained from three rectangular apertures arranged in a regular polygon shape. We also propose the Modulation Transfer Function Loss, MTF Loss, which can capture the high-frequency components of the images. We present qualitative and quantitative results obtained through experiments.

Vibratory pattern analysis of vocal folds for layngeal function assessment usig electroglottograph system

  • Song, Chulgyu;Lee, Myoungho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.583-585
    • /
    • 1994
  • In this study, we have evaluated the effect of amplitude and frequency perturbation of EGG signal during single vowels associated with laryngeal pathology. The normal EGG signal is properly characterized by an autoregressive model which has the optimal order of ninth using the parametric method. This can be analyzed by determining the transfer function. Perturbations in the fundamental pitch and in the peak amplitude of EGG signal derived with a four-electrode system using the modulation/demodulation techniques were investigated for the purpose of developing a decision criteria for the laryngeal function identification.

  • PDF

Simulation of the Through-Focus Modulation Transfer Functions According to the Change of Spherical Aberration in Pseudophakic Eyes

  • Kim, Jae-hyung;Kim, Myoung Joon;Yoon, Geunyoung;Kim, Jae Yong;Tchah, Hungwon
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.403-408
    • /
    • 2015
  • To evaluate the effects of spherical aberration (SA) correction on optical quality in pseudophakic eyes, we simulated the optical quality of the human eye by computation of the modulation transfer function (MTF). We reviewed the medical records of patients who underwent cataract surgery in Asan Medical Center, retrospectively. A Zywave aberrometer was used to measure optical aberrations at 1-12 postoperative months in patients with AR40e intraocular lens implants. The MTF was calculated for a 5 mm pupil from measured wavefront aberrations. The area under the MTF curve (aMTF) was analyzed and the maximal aMTF was calculated while changing the SA ($-0.2{\sim}+0.2{\mu}m$) and the defocus (-2.0 ~ +2.0 D). Sixty-four eyes in 51 patients were examined. The maximal aMTF was $6.61{\pm}2.16$ at a defocus of $-0.25{\pm}0.66D$ with innate SA, and $7.64{\pm}2.63$ at a defocus of $0.08{\pm}0.53D$ when the SA was 0 (full correction of SA). With full SA correction, the aMTF increased in 47 eyes (73.4%; Group 1) and decreased in 17 eyes (26.6%; Group 2). There were statistically significant differences in Z(3, -1) (vertical coma; P = 0.01) and Z(4, 4) (tetrafoil; P = 0.04) between the groups. The maximal aMTF was obtained at an SA of $+0.01{\mu}m$ in Group 1 and an SA of $+0.13{\mu}m$ in Group 2. Optical quality can be improved by full correction of SA in most pseudophakic eyes. However, residual SA might provide benefits in eyes with significant radially asymmetric aberrations.

Correction Method of Slit Modulation Transfer function on Digital Medical Imaging System (디지털 의료영상에서 슬릿법에 의한 Modulation Transfer Function의 보정방법)

  • Kim, Jung-Min;Jung, Hoi-Woun;Min, Jung-Whan;Im, Eon-Kyung
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • By using CR image pixel data, We examined the way how to calculate the MTF and digital characteristic curve. It can be changed to the text-file(Excel) from a pixel data which was printed with a digital x-ray equipment. In this place, We described the way how to figure out and correct the sharpness of a digital images of the MTF from FUJITA. Excel program was utilized to calculate from radiography of slit. Digital characteristic curve, Line Spread Function, Discrete Fourier Transform, Fast Fourier Transform digital specification curve, were indicated in regular sequence. A big advantage of this method, It can be understood easily and you can get results without costly program and without full knowledge of computer language. It shows many different values by using different correction methods. Therefore we need to be handy with appropriate correction method and we should try many experiments to get a precise MTF figures.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

MTF Characteristics in GEO Meteorological Imager (정지궤도 기상위성 영상기 MTF 특성 분석)

  • 조영민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.30-31
    • /
    • 2003
  • 본 연구에서는 통신해양기상위성의 기상관측 탑재체인 기상 영상기(Imager)의 개발을 위해 정지궤도 위성의 분광 채널별 Modulation Transfer Function (MTF) 특성을 현재 운영 및 개발 중인 위성 영상기 기술 범위에서 분석하였다. 통신해양기상위성은 국내 최초로 통신, 해양, 기상 3분야 복합 임무를 수행하는 정지제도 위성으로 2003년부터 개발되어 2008년 발사 예정이다. (중략)

  • PDF

Pixel-Structured Scintillator with Polymeric Microstructures for X-Ray Image Sensors

  • Jung, Im-Deok;Cho, Min-Kook;Bae, Kong-Myeong;Lee, Sang-Min;Jung, Phill-Gu;Kim, Ho-Kyung;Kim, Sung-Sik;Ko, Jong-Soo
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.747-749
    • /
    • 2008
  • We introduce a pixel-structured scintillator realized on a flexible polymeric substrate and demonstrate its feasibility as an X-ray converter when it is coupled to photosensitive elements. The sample was prepared by filling $Gd_2O_2S:Tb$ scintillation material into a square-pore-shape cavity array fabricated with polyethylene. For comparison, a sample with the conventional continuous geometry was also prepared. Although the pixelated geometry showed X-ray sensitivity of about 58% compared with the conventional geometry, the resolving power was improved by about 70% above a spatial frequency of 3 $mm^{-1}$. The spatial frequency at 10% of the modulation-transfer function was about 6 $mm^{-1}$.

  • PDF