• 제목/요약/키워드: Modular Structures

검색결과 160건 처리시간 0.024초

40m 조합모듈교량 상부구조 이송에 따른 안전성 검토 (Safety Evaluation of 40m Combined Modular Bridge Super-Structures Based on Transportation Lifting Methods)

  • 박성민;정우영
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.77-84
    • /
    • 2015
  • The purpose of this study was the analytical safety evaluation on the super-structure of precast modular bridge using standardized modular members and robotic construction during the transportation routing and lifting conditions. In order to evaluate the safety performance of the bridge system, 3-D full scale Finite Element (FE) of 40 m standardized modular block was developed in ABAQUS, followed by the analytical study to classify the structural system according to steel girder structures: 1) modular bridge block lifting method including the steel girder system; 2) modular bridge block lifting method without the steel girder system. The results from the analytical study revealed that the maximum stress of each modular member was within the maximum allowable stresses during lifting condition. However, the stress concentration at the connected area was more critical in comparison to the behavior of 40 m combined modular blocks during lifting time

연결 플레이트를 사용한 프리캐스트 콘크리트 모듈러 보의 전단성능 (Shear Behaviour of Precast Concrete Modular Beam Using Connecting Plate)

  • 조창근;노경민;이영학
    • 한국공간구조학회논문집
    • /
    • 제21권4호
    • /
    • pp.65-72
    • /
    • 2021
  • The Precast concrete(PC) modular structures are a method of assembling pre-fabricated unit modules in the construction site. The essential aim of modular structures is to introduce a connection method that can ensure splicing performance and effectively resist shear strength. This study proposed PC module using a connecting plate that can replace splice sleeves and shear keys used in the conventional PC modular structures. To evaluate the splicing performance and shear capacity of the proposed method, the shear test was conducted by fabricating one monolithic reinforced concrete(RC) beam and two PC modular beams with a shear span-to-depth ratio as variables. The experimental results showed that the shear capacity of the PC modular beam was about 89% compared to that of the RC beam, and showed a failure of the RC beam according to the shear span-to-depth ratio. Therefore, it was considered that the connecting plate effectively transferred the stress between each PC module through the joint and ensure integrity. In addition, the applicability of shear strength equation of ACI 318-19 and Zsutty's equation to PC modular beams were evaluated. Results demonstrated that the improved shear strength equations are needed to consider reduction of shear strength in PC modules.

모듈러 구조물의 해석 모델이 지진응답에 미치는 영향 (Influence of Analytical Models on the Seismic Response of Modular Structures)

  • 최경석;이호찬;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.74-85
    • /
    • 2016
  • 모듈러 구조물은 관행적으로 철골 모멘트 저항골조와 유사한 횡력저항성능을 가진다는 가정하에 내진 설계된다. 하지만 모듈러 구조물은 중첩된 구조 부재와 단위 모듈의 체결을 위한 복잡한 접합 상세를 가지기 때문에 철골 모멘트 골조와 다른 하중 전달 메커니즘을 가진다. 본 연구에서는 중첩된 구조 부재 효과와 접합부의 거동 특성을 고려하여 총 4개의 구조해석 모델을 수립하였으며, 수립된 해석 모델을 이용하여 3층과 5층 표본 건물에 대한 비선형 정적 해석을 수행하였다. 표본 건물은 중첩된 구조 부재와 접합부의 이력 거동에 대한 모델링 방법에 따라 강성 및 강도의 차이가 발생하는 것으로 나타났다. 중첩된 구조 부재를 완전 합성, 모듈 간 접합부를 강접합으로 고려하여 설계된 모듈러 구조물은 횡 강성 및 강도가 과대 평가되는 것으로 나타났다. 뿐만 아니라 해석 결과를 통해 3층 이상의 모듈러 구조물은 철골 모멘트 저항골조와 비교하여 상대적으로 적은 초과 강도를 가지는 것을 확인할 수 있다.

연결 강판을 이용한 모듈러 유닛 간 접합부의 비선형 거동 해석 (Nonlinear Behavior Analysis of Connections Between Modular Units Using Connecting Steel Plate)

  • 김현구;유정한
    • 한국공간구조학회논문집
    • /
    • 제23권2호
    • /
    • pp.45-52
    • /
    • 2023
  • Modular construction is an economical and efficient construction that reduces time and costs by manufacturing units in factories and constructing them on site. Currently, the demand for modular construction is increasing not only abroad but also domestically. As the demand for modular construction increases, a lot of development and research on connections between modular units are being conducted. Connections between modular units should be quick and simple to assemble when assembling units on site, and should be in a form that allows each unit to be connected regardless of direction. In addition, it must be able to exert sufficient strength against external loads. In this study, a connection between modular units using connecting steel plates and bolts was proposed, and the nonlinear behavior of the connection to external lateral force was analyzed through finite element analysis, and resistance performance was evaluated.

샌드위치 복합재와 알루미늄 압출재를 적용한 하이브리드 경량 차체 구조물의 모듈화 설계 연구 (A Study on the Modular Design of Hybrid Lightweight Carbody Structures Made of Sandwich Composites and Aluminum Extrusion)

  • 장형진;신광복;한성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2644-2649
    • /
    • 2011
  • The purpose of this study is to propose the modular design of hybrid lightweight carbody structures made of sandwich composites and aluminum extrusion. The sandwich composites were used for secondary structures to minimize the weight of carbody, and the aluminum extrusions were applied to primary structures to improve the stiffness of carbody and manufacturability. Key requirements were defined for the modular design of hybrid carbody, and the applied parts of sandwich composites were determined through the topology optimization analysis. Consequently, feasibility of enhancing mass saving and maintainability in modular hybrid carbody design were presented, comparing with the carbody structures made of aluminum extrusion or sandwich composites only.

  • PDF

Optimization of modular Truss-Z by minimum-mass design under equivalent stress constraint

  • Zawidzki, Machi;Jankowski, Lukasz
    • Smart Structures and Systems
    • /
    • 제21권6호
    • /
    • pp.715-725
    • /
    • 2018
  • Truss-Z (TZ) is an Extremely Modular System (EMS). Such systems allow for creation of structurally sound free-form structures, are comprised of as few types of modules as possible, and are not constrained by a regular tessellation of space. Their objective is to create spatial structures in given environments connecting given terminals without self-intersections and obstacle-intersections. TZ is a skeletal modular system for creating free-form pedestrian ramps and ramp networks. The previous research on TZ focused on global discrete geometric optimization of the spatial configuration of modules. This paper reports on the first attempts at structural optimization of the module for a single-branch TZ. The internal topology and the sizing of module beams are subject to optimization. An important challenge is that the module is to be universal: it must be designed for the worst case scenario, as defined by the module position within a TZ branch and the geometric configuration of the branch itself. There are four variations of each module, and the number of unique TZ configurations grows exponentially with the branch length. The aim is to obtain minimum-mass modules with the von Mises equivalent stress constrained under certain design load. The resulting modules are further evaluated also in terms of the typical structural criterion of compliance.

Cyclic and static behaviors of CFT modular bridge pier with enhanced bracings

  • Kim, Dongwook;Jeon, Chiho;Shim, Changsu
    • Steel and Composite Structures
    • /
    • 제20권6호
    • /
    • pp.1221-1236
    • /
    • 2016
  • Modular structures consist of standardized modules and their connections. A modular bridge pier is proposed to accelerate bridge construction. Multiple concrete-filled steel tubes (CFTs) using commercial steel tubes were chosen as the main members. Buckling restrained bracings and enhanced connection details were designed to prevent premature low-cycle fatigue failure upon cyclic loading. The pier had a height of 7.95 m, widths of 2.5 m and 2.0 m along the strong and weak axis, respectively. Cyclic tests were performed on the modular pier to investigate structural performance. Test results showed that four CFT columns reached yielding without a premature failure of the bracing connections. The ultimate capacity of the modular pier was reasonably estimated based on the plastic-hinge-analysis concept. The modular CFT pier with enhanced bracing showed improved displacement ductility without premature failure at the welding joints.

철골 모듈러 구조물의 포스트텐션 기둥-바닥 접합부 거동에 대한 해석적 연구 (Analytical Study on Structural Behaviors of Post-Tensioned Column-Base Connections for Steel Modular Structures)

  • 최경석;신동현;김형준
    • 한국전산구조공학회논문집
    • /
    • 제33권6호
    • /
    • pp.427-435
    • /
    • 2020
  • 모듈러 건축물은 철근콘크리트 및 철골 구조물에 비하여 상대적으로 경량이고, 단위 모듈간 기둥의 일체성을 기대하기 어려운 구조적 특성을 가진다. 이와 같은 구조적 특성은 모듈러 건축물의 높이가 높아짐에 따라 바람 및 지진과 같은 횡력저항성능에 직접적인 영향을 미친다. 본 연구에서는 횡력저항성능을 향상시키기 위해 긴장재를 활용한 모듈러 구조시스템을 제안하였다. 모듈러 구조시스템을 구성하는 주요 요소인 포스트텐션 기둥-바닥 접합부는 셀프 센터링 거동을 유도하기 위한 형상 및 상세를 가진다. 포스트텐션 기둥-바닥 접합부의 이력 거동을 상세히 파악하기 위해 유한요소해석을 수행하였으며, 그 결과 초기 긴장력 및 보-기둥 접합부의 접합 조건에 따라 이력 거동은 확연한 차이를 보이는 것으로 나타났다.

4-클립 체결방식을 갖는 모듈러 하우스의 내진성능평가 (Seismic performance evaluations of modular house having 4-clip fastening method)

  • 임현진;조창근;신정강;이선주
    • 한국공간구조학회논문집
    • /
    • 제22권3호
    • /
    • pp.41-48
    • /
    • 2022
  • The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.