• 제목/요약/키워드: Modified Mask

검색결과 109건 처리시간 0.023초

MASK 방법에 의한 이론함수의 최소화 (On the Minimization of the Switching Function by the MASK Method)

  • 조동섭;황희융
    • 전기의세계
    • /
    • 제28권11호
    • /
    • pp.37-44
    • /
    • 1979
  • This paper deals with the computer program of finding the minimal sum-of-products for a switching function by using the MASK method derived from the characteristics of the Boolean algebra. The approach differs from the previous procedures in that all the prime implicants are determined only by the bit operation and the minimal sum-of-products are obtained by the modified Petrick method in this work. The important features are the relatively small amount of the run time and the less memory capacity to solve a problem, as compared to the previous computer programs.

  • PDF

임펄스 잡음 제거를 위한 변형된 메디안 필터 (Modified Median Filter for Impulse Noise Removal)

  • ;김남호
    • 한국정보통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.461-466
    • /
    • 2013
  • 사회가 고도의 디지털 정보화 시대로 발전함에 따라 영상복원 등 디지털 영상처리 기술분야에 관한 많은 연구가 진행되고 있다. 임펄스 잡음에 훼손된 영상을 복원하는데 대표적인 방법은 SM(Standard Median) 필터가 있지만, SM 필터는 에지영역에서 오류를 나타내어 영상의 품질을 저하시킨다. 본 논문에서는 임펄스 잡음환경에서 훼손된 영상을 복원하기 위해 화소를 중심으로 하여 이중 마스크를 취하는 변형된 메디안 필터 알고리즘을 제안하였다. 이중 마스크를 취함에 따라 제안한 방법은 우수한 잡음제거 및 에지보존 특성을 나타내었고 영상의 화질을 개선하였다.

Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

  • Park, Seoryeong;Boo, Jiwhan;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1266-1276
    • /
    • 2021
  • The mask parameters of a coded aperture are critical design features when optimizing the performance of a gamma-ray camera. In this paper, experiments and Monte Carlo simulations were performed to derive the minimum detectable activity (MDA) when one seeks a real-time imaging capability. First, the impact of the thickness of the modified uniformly redundant array (MURA) mask on the image quality is quantified, and the imaging of point, line, and surface radiation sources is demonstrated using both cross-correlation (CC) and maximum likelihood expectation maximization (MLEM) methods. Second, the minimum detectable activity is also derived for real-time imaging by altering the factors used in the image quality assessment, consisting of the peak-to-noise ratio (PSNR), the normalized mean square error (NMSE), the spatial resolution (full width at half maximum; FWHM), and the structural similarity (SSIM), all evaluated as a function of energy and mask thickness. Sufficiently sharp images were reconstructed when the mask thickness was approximately 2 cm for a source energy between 30 keV and 1.5 MeV and the minimum detectable activity for real-time imaging was 23.7 MBq at 1 m distance for a 1 s collection time.

크리프에 따른 CRT 텐션 마스크의 장력 이완 (Creep-Induced Tension Loosening of CRT Tension Mask)

  • 정일섭
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.1034-1040
    • /
    • 2003
  • Tension mask is a part of CRT type devices, which is installed right behind glass-made front panel. Numerous slits on the thin metal sheet enable the electron beams emitted from posterior gun to be focused, resulting in enhanced definition. Flattened and enlarged displays necessitate the imposition of pretension on the masks, in order to improve the robustness of display quality against vibration or impact. High temperature assembly process subsequent to pretensioning, however, degenerates creep resistance of mask material, and common mask may become susceptible to undesirable elongation due to creep. Once tensile stress becomes high enough to induce creep deformation, pretension is substantially loosened. In this study, tension mask assembly is modeled as a combined structure of beams and wire array, and a numerical simulation is attempted for pretensioning followed by high temperature process. Based on a model study, creep occurrence is found to be probable and its adverse influence is quantified. As fur maintaining high tensile force, simply increasing pretension does not seem to be helpful. Instead, the structure of frame needs to be modified somehow, or material for mask needs to be selected properly.

Development of physically based 3D computer simulation code TRICSI for ion implantation into crystalline silicon

  • Son, Myung-Sik;Lee, Jun-Ha;Hwang, Ho-Jung
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제1권1호
    • /
    • pp.1-12
    • /
    • 1997
  • A new three-dimensional (3D) Monte Carlo ion implantation simulator, TRICSI, has been developed to investigate 3D mask effects in the typical mask structure for ion implantation into crystalline silicon. We present the mask corner and mask size effects of implanted boron range profiles, and also show the calculated damage distributions by applying the modified Kinchin-Pease equation in the single-crystal silicon target. The simulator calculates accurately and efficiently the implanted-boron range profiles under the relatively large implanted area, using a newly developed search algorithm for the collision partner in the single-crystal silicon. All of the typical implant parameters such as dose, tilt and rotation angles, in addition to energy can be used for the 3D simulation of ion implantation.

변형된 확장 마스크를 이용한 에지 검출에 관한 연구 (A Study on the Edge Detection using Modified Expansion Mask)

  • 이창영;황용연;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.630-632
    • /
    • 2012
  • 현대사회는 디지털 정보화시대로 변화하고 있으며, 이로 인해 다양한 영상들의 이용이 증가하고 있다. 이러한 영상을 처리하기 위하여, 다양한 디지털 영상 처리 기법이 이용되고 있다. 그 중 에지검출 기법은 물체 인식, 차선 검출 등 여러 응용 분야에 활용되고 있다. 기존의 에지 검출 기법은 Sobel, Prewitt, Roberts, Laplacian 등이 있다. 하지만 이러한 기존의 방법들로 처리한 영상들은 영상을 주변 화소의 변화정도와 관계없이 동일하게 영상을 처리하기 때문에, 에지 검출 특성이 다소 미흡하다. 따라서 본 연구에서는 기존의 방법들의 단점을 개선하기 위하여, 변형된 확장 마스크를 이용한 에지 검출 알고리즘을 제안하였다.

  • PDF

임펄스 잡음환경에서 변형된 적응 메디안 필터에 관한 연구 (A Study on Modified Adaptive Median Filter in Impulse Noise Environment)

  • ;안영주;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.883-885
    • /
    • 2013
  • 영상복원은 영상에 첨가되는 여러가지 잡음을 제거하여 잡음이 영상에 미치는 영향을 줄이는 것이다. 영상복원을 위해, 평균 필터, 메디안 필터, 가중치 필터 등 방법들이 제안되었으나 이러한 기존의 방법들은 잡음제거 및 에지 보존 성능이 미흡하다. 따라서 본 논문에서는 효과적으로 잡음을 제거하기 위해 마스크 메디안 값의 여부에 따라 마스크 크기를 확대 시키는 변형된 적응 메디안 필터 알고리즘을 제안하였다. 그리고 시뮬레이션을 통해 기존의 방법들과 비교하였으며 판단의 기준으로 MSE(mean squared error)를 사용하였다.

  • PDF

AWGN 제거를 위한 변형된 평균필터 (The Modified Mean Filter to Remove AWGN)

  • ;김남호
    • 한국정보통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.1177-1182
    • /
    • 2011
  • 영상신호를 처리하는 과정에서 다양한 잡음에 의해 영상의 열화가 발생하고 있으며, 가우시안 잡음은 전송 등의 과정에서 영상에 의존적으로 발생한다. 이러한 가우시안 잡음을 제거하기 위한 다양한 연구가 이루어지고 있다. 본 논문에서는 AWGN을 제거하기 위하여 마스크 내의 표준편차를 구하고 그 값을 임계값과 비교하여 레벨을 나누어 마스크 내의 각 화소값에 주는 가중치를 구한 후, 평균치를 출력영상의 화소값으로 하는 변형된 weighted mean filter를 제안하였다. 그리고 시뮬레이션을 통해 기존의 방법들과 그 성능을 비교하였고 판단기준으로 PSNR을 사용하였다.

임펄스 잡음 제거를 위한 변형된 적응 메디안 필터에 관한 연구 (A Study on Modified Adaptive Median Filter for Impulse Noise Removal)

  • ;안영주;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.804-806
    • /
    • 2014
  • 영상의 처리 및 전송과정에서 여러가지 잡음이 첨가되어 영상에 오류를 발생시킨다. 이러한 영상을 복원하기 위해, 알파 트림드 평균 필터, 표준 메디안 필터, 스위칭 메디안 필터 등의 방법들이 제안되었으나 이러한 기존의 방법들은 잡음제거 특성이 미흡하다. 따라서 본 논문에서는 영상에 첨가되는 임펄스 잡음을 제거하기 위해 마스크 내의 화소의 잡음 밀도에 따라 마스크를 확대 시키는 변형된 적응 메디안 필터 알고리즘을 제안하였다.

  • PDF

Investigation of nuclear material using a compact modified uniformly redundant array gamma camera

  • Lee, Taewoong;Kwak, Sung-Woo;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.923-928
    • /
    • 2018
  • We developed a compact gamma camera based on a modified uniformly redundant array coded aperture to investigate the position of a $UO_2$ pellet emitting characteristic X-rays (98.4 keV) and ${\gamma}-rays$ (185.7 keV). Experiments using an only-mask method and an antimask subtractive method were conducted, and the maximum-likelihood expectation maximization algorithm was used for image reconstruction. The images obtained via the antimask subtractive method were compared with those obtained using the only-mask method with regard to the signal-to-noise ratio. The reconstructed images of the antimask subtractive method were superior. The reconstructed images of the characteristic X-rays and the ${\gamma}-rays$ were combined with the obtained image using the optical camera. The combined images showed the precise position of the $UO_2$ pellet. According to the self-absorption ratios of the nuclear material and the minimum number of effective events for image reconstruction, we estimated the minimum detection time depending on the amount of nuclear material.