• Title/Summary/Keyword: Modeling, Heat Transfers

Search Result 9, Processing Time 0.023 seconds

MULTI-DIMENSIONAL APPROACHES IN SEVERE ACCIDENT MODELLING AND ANALYSES

  • Fichot, F.;Marchand, O.;Drai, P.;Chatelard, P.;Zabiego, M.;Fleurot, J.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.733-752
    • /
    • 2006
  • Severe accidents in PWRs are characterized by a continuously changing geometry of the core due to chemical reactions, melting and mechanical failure of the rods and other structures. These local variations of the porosity and other parameters lead to multi-dimensionnal flows and heat transfers. In this paper, a comprehensive set of multi-dimensionnal models describing heat transfers, thermal-hydraulics and melt relocation in a reactor vessel is presented. Those models are suitable for the core description during a severe accident transient. A series of applications at the reactor scale shows the benefits of using such models.

Modeling of Coke Combustion and Heat Transfer in an Iron Ore Sintering Bed with Considerations of Multiple Solid Phases (다중 고체상을 고려한 소결기의 코크스 연소-열전달 모델링)

  • Yang, Won;Ryu, Chang-Kook;Choi, Sang-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.79-84
    • /
    • 2003
  • In this study we propose an unsteady I-dimensional model of an iron ore sintering bed with multiple solid phases, which confers a phase on each solid material. This model contains coke combustion, limestone decomposition, gaseous reaction, heat transfers between each phase, and geometric changes of the solid particles. Simulation results are compared with the limited experimental data set of various coke contents and air supply rates. Effect of the coke diameter is also evaluated. They predict the experimental results well and show applicabilities to the various system of the fuel bed with various solid materials.

  • PDF

Combustion Modeling of a Solid Fuel Bed with Consideration of the Multiple Solid Phases (다중 고체상을 고려한 고체 연료층 연소 모델링)

  • Yang, Won;Ryu, Chang-Kook;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.119-127
    • /
    • 2003
  • In this study we propose an unsteady I-dimensional model of bed combustion with multiple solid phases, which confers a phase on each solid material. This model can be applied to a variety of bed combustion cases of various configurations and ignition methods. It contains fuel combustion, gaseous reaction, heat transfers between each phase, and geometric changes of the solid particles. An iron ore sintering pot is selected for verifying the model validity and simulation results are compared with the limited experimental data set of various coke contents and air supply rates. They predict the experimental results well and show applicabilities to the various system of the fuel bed with various solid materials.

  • PDF

Macroscopic High-Temperature Structural Analysis Model of Small-Scale PCHE Prototype (II) (소형 PCHE 시제품에 대한 거시적 고온 구조 해석 모델링 (II))

  • Song, Kee-Nam;Lee, Heong-Yeon;Hong, Sung-Deok;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1137-1143
    • /
    • 2011
  • The IHX (intermediate heat exchanger) of a VHTR (very high-temperature reactor) is a core component that transfers the high heat generated by the VHTR at $950^{\circ}C$ to a hydrogen production plant. Korea Atomic Energy Research Institute manufactured a small-scale prototype of a PCHE (printed circuit heat exchanger) that was being considered as a candidate for the IHX. In this study, as a part of high-temperature structural integrity evaluation of the small-scale PCHE prototype, we carried out high-temperature structural analysis modeling and macroscopic thermal and elastic structural analysis for the small-scale PCHE prototype under small-scale gas-loop test conditions. The modeling and analysis were performed as a precedent study prior to the performance test in the small-scale gas loop. The results obtained in this study will be compared with the test results for the small-scale PCHE. Moreover, these results will be used in the design of a medium-scale PCHE prototype.

Predicting the Impact of Food Processing on the Physical Properties of Food

  • Zuo, Li;Lee, Jun-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.8 no.4
    • /
    • pp.419-424
    • /
    • 2003
  • The physical properties of food playa significant role in the modeling and computation of the heat and mass transfers in basic food processing operations. With the advent of improved analytical techniques, statistical experiment design applications, computing ability and knowledge of the food physical properties of food, there have been significant advances in our ability to predict the impact of processing on the physical properties of food. This article briefly reviews our current ability to predict the influence of processing on the physical properties of food, such as water activity, moisture, color, and rheological characteristics.

Evaluation of High-Temperature Structural Integrity Using Lab-Scale PCHE Prototype (SUS316L 로 제작된 실험실 수준 인쇄기판형 열교환기 시제품의 고온구조건전성 평가)

  • Song, Kee Nam;Hong, Sung Deok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1189-1194
    • /
    • 2013
  • The Intermediate Heat Exchanger (IHX) of a Very High Temperature Reactor (VHTR) is a core component that transfers the high heat of $950^{\circ}C$ generated in the VHTR to a hydrogen production plant. The Korea Atomic Energy Research Institute manufactured a lab-scale prototype of a Printed Circuit Heat Exchanger (PCHE) as a candidate for an IHX. In this study, as a part of a high-temperature structural integrity evaluation of the lab-scale PCHE prototype made of SUS316L, we carried out high temperature structural analysis modeling and macroscopic thermal and elastic structural analysis for the lab-scale PCHE prototype under helium experimental loop (HELP) test conditions as a precedent study prior to the performance test in HELP.

High-temperature Structural Analysis of Small-scale Prototype of Process Heat Exchanger (III) (공정열교환기 소형 시제품에 대한 고온구조해석(III))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Seong-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.2
    • /
    • pp.191-200
    • /
    • 2011
  • A PHE (Process Heat Exchanger) is a key component of nuclear hydrogen system for massive production of hydrogen; the PHE transfers the very high temperature heat ($950^{\circ}C$) generated from the VHTR (Very High Temperature Reactor) to a chemical reaction. The Korea Atomic Energy Research Institute developed a small-scale gas loop for testing the performance of VHTR components and manufactured a modified PHE prototype for carrying out the testing in the gas loop. In this study, as a part of the evaluation of the high-temperature structural integrity of the modified PHE prototype which is scheduled to test in the gas loop, we carried out high-temperature structural analysis modeling, macroscopic thermal and structural analysis of the PHE prototype under the gas loop test conditions as a precedent study before carrying out the performance test in the gas loop. The results obtained in this study will be used to design the performance test setup for the modified PHE prototype.

Features of Residual Stress and Plastic Strain in Titanium/Aluminium Friction Welds (티탄과 알루미늄의 마찰용접에서 발생하는 잔류응력.소성변형)

  • 김유철;박정웅
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.84-89
    • /
    • 2000
  • Friction welding of titanium and aluminium is numerically modeled by the axisymmetric thermal elastic-plastic analysis. In titanium/aluminium friction welding, heat transfers into the titanium substrate to a distance of z=10(mm) on the side of the bondline and into the whole region of the aluminium substrate having the large thermal conductivity. Adjacent to the bondline, $^{\sigma}r\;and\;^{\sigma\theta}$ are tensile in the substrate whose thermal shrinkage is large, and are compressive in the substrate whose thermal shrinkage is small. $\sigma_z$ along the radial direction is large tensile at the periphery of the component. Plastic strain occurs only close to the bondline in the aluminium substrate. In the components of plastic strain, $\varepsilon^p_r\;and\;\varepsilon^p_{\theta}$ have positive values and $\varepsilon^p_r$ has large negative value. However, $\varepsilon^p_r$ is produced not because of the severity of the mechanical restraint condition, but on purpose to satisfy the condition of the volume constant. A plastic work is proposed as a measure to evaluate the mechanical severity. The plastic work is larger in the aluminium substrate than that in the titanium substrate. The mechanical condition is severer in the aluminium substrate.

  • PDF

Macroscopic High-Temperature Structural Analysis Model for a Small-Scale PCHE Prototype (I) (소형 PCHE 에 대한 거시적 고온 구조 해석 모델링 (I))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Sung-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1499-1506
    • /
    • 2011
  • The IHX (intermediate heat exchanger) is a key component of nuclear hydrogen systems for the production of massive amounts hydrogen. The IHX transfers the $950^{\circ}C$ heat generated by the VHTR (very high temperature reactor) to a hydrogen production plant. The Korea Atomic Energy Research Institute established a small-scale gas loop to test the performance of key VHTR components and manufactured a small-scale PCHE (printed circuit heat exchanger) prototype, which is being considered as a candidate for the IHX, for testing in the small-scale gas loop. In this study, as a part of the high-temperature structural integrity evaluation of the small-scale PCHE prototype, we carried out high-temperature structural analysis modeling and macroscopic thermal and structural analysis for the small-scale PCHE prototype under the small-scale gas loop test conditions. This analysis serves as a precedent study to scheduled PCHE performance test in the small-scale gas loop. The results obtained in this study will be compared with the test results for the small-scale PCHE and then used to design the medium-scale PCHE prototype.