• Title/Summary/Keyword: Model surgery

Search Result 1,539, Processing Time 0.033 seconds

Qualitative correlation between postoperatively increased vertical dimension and mandibular position in skeletal class III using partial-least-square path modeling

  • Kim, Na-Ri;Park, Soo-Byung;Lee, Jihyun;Choi, Youn-Kyung;Shin, Sang Min;Choi, Yong-Seok;Kim, Yong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.15.1-15.7
    • /
    • 2017
  • Background: This study constructed a partial-least-square path-modeling (PLS-PM) model and found the pathway by which the postsurgical vertical dimension (VD) affects the extent of the final mandibular setback on the B point at the posttreatment stage for the skeletal class III surgery-first approach (SFA). Methods: This study re-analyzed the data from the retrospective study by Lee et al. on 40 patients with skeletal class III bimaxillary SFA. Variables were obtained from cone beam computed tomography (CBCT)-generated cephalograms. Authors investigated all variables at each time point to build a PLS-PM model to verify the effect of the VD on the final setback of the mandible. Results: From PLS-PM, an increase in $VD_{10}$ was found to decrease the absolute value of the final setback amount of the mandible, which reflects the postsurgical physiological responses to both surgery and orthodontic treatment, which, in turn, can be interpreted as an increase in postoperative mandibular changes. Conclusions: To resolve the issue of collinear cephalometric data, the present study adopted PLS-PM to assess the orthodontic treatment. From PLS-PM, it was able to summarize the effect of increased postsurgery occlusal vertical dimension on the increased changeability of the B point position at the posttreatment stage.

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Improved motility in the gastrointestinal tract of a postoperative ileus rat model with ilaprazole

  • Kim, Geon Min;Sohn, Hee Ju;Choi, Won Seok;Sohn, Uy Dong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.6
    • /
    • pp.507-515
    • /
    • 2021
  • Postoperative ileus (POI), a symptom that occurs after abdominal surgery, reduces gastrointestinal motility. Although its mechanism is unclear, POI symptoms are known to be caused by inflammation 6 to 72 h after surgery. As proton pump inhibitors exhibit protective effect against acute inflammation, the purpose of this study was to determine the effect of ilaprazole on a POI rat model. POI was induced in rats by abdominal surgery. Rats were divided into six groups: control: normal rat + 0.5% CMC-Na, vehicle: POI rat + 0.5% CMC-Na, mosapride: POI rat + mosapride 2 mg/kg, ilaprazole 1 mg/kg: POI rat + ilaprazole 1 mg/kg, ilaprazole 3 mg/kg: POI rat + ilaprazole 3 mg/kg, and ilaprazole 10 mg/kg: POI rat + ilaprazole 10 mg/kg. Gastrointestinal motility was confirmed by measuring gastric emptying (GE) and gastrointestinal transit (GIT). In the small intestine, inflammation was confirmed by measuring TNF-α and IL-1β; oxidative stress was confirmed by SOD, GSH, and MDA levels; and histological changes were observed by H&E staining. Based on the findings, GE and GIT were decreased in the vehicle group and improved in the ilaprazole 10 mg/kg group. In the ilaprazole 10 mg/kg group, TNF-α and IL-1β levels were decreased, SOD and GSH levels were increased, and MDA levels were decreased. Histological damage was also reduced in the ilaprazole-treated groups. These findings suggest that ilaprazole prevents the decrease in gastrointestinal motility, a major symptom of postoperative ileus, and reduces inflammation and oxidative stress.

Development of Korean Teaching Model for Surgical Procedures in Trauma -Essential Surgical Procedures in Trauma Course-

  • Kim, Hohyun;Park, Chan-Yong;Cho, Hyun-Min;Yeo, Kwang-Hee;Kim, Jae Hun;Yu, Byungchul;Go, Seung-Je;Kwon, Oh Sang
    • Journal of Trauma and Injury
    • /
    • v.32 no.1
    • /
    • pp.8-16
    • /
    • 2019
  • Purpose: The Essential Surgical Procedures in Trauma (ESPIT) course was developed as a model to teach necessary surgical procedures to trauma physicians. Its goals are to improve knowledge, self-confidence, and technical competence. Methods: The ESPIT course consisted of five lectures and a porcine lab operative experience. The ESPIT course has been run seven times between February 2014 and April 2016. ESPIT participants completed a questionnaire to assess self-efficacy regarding essential surgical procedures in trauma before and immediately after taking the ESPIT course. Sixty-three participants who completed both pre- and post-course questionnaires on self-efficacy were enrolled in this study. Results: The overall post-ESPIT mean self-efficacy score was higher than the pre-ESPIT mean self-efficacy score ($8.3{\pm}1.30$ and $4.5{\pm}2.13$, respectively) (p<0.001). Self-efficacy was significantly improved after the ESPIT course in general surgeons (p<0.001), thoracic and cardiovascular surgeons (p<0.001), emergency medicine doctors, and others (neurosurgeons, orthopedic surgeons) (p<0.001). The differences in self-efficacy score according to career stage (<1 year, 1-3 years, 3-5 years, and >5 years) were also statistically significant (p<0.001). Conclusions: The data of the ESPIT participants indicated that they felt that the ESPIT course improved their self-efficacy with regard to essential surgical procedures in trauma. The ESPIT course may be an effective strategy for teaching surgical procedures, thus promoting better management of traumatic injuries.

Role of Ischemic Preconditioning in the Cardioprotective Mechanisms of Monomeric C-Reactive Protein-Deposited Myocardium in a Rat Model

  • Kim, Eun Na;Choi, Jae-Sung;Kim, Chong Jai;Kim, So Ra;Oh, Se Jin
    • Journal of Chest Surgery
    • /
    • v.54 no.1
    • /
    • pp.9-16
    • /
    • 2021
  • Background: The deposition of monomeric C-reactive protein (mCRP) in the myocardium aggravates ischemia-reperfusion injury (IRI) and myocardial infarction. Ischemic preconditioning (IPC) is known to protect the myocardium against IRI. Methods: We evaluated the effects of IPC on myocardium upon which mCRP had been deposited due to IRI in a rat model. Myocardial IRI was induced via ligation of the coronary artery. Direct IPC was applied prior to IRI using multiple short direct occlusions of the coronary artery. CRP was infused intravenously after IRI. The study included sham (n=3), IRI-only (n=5), IRI+CRP (n=9), and IPC+IRI+CRP (n=6) groups. The infarcted area and the area at risk were assessed using Evans blue and 2,3,5-triphenyltetrazolium staining. Additionally, mCRP immunostaining and interleukin-6 (IL-6) mRNA reverse transcription-polymerase chain reaction were performed. Results: In the IRI+CRP group, the infarcted area and the area of mCRP deposition were greater, and the level of IL-6 mRNA expression was higher, than in the IRI-only group. However, in the IPC+IRI+CRP group relative to the IRI+CRP group, the relative areas of infarction (20% vs. 34%, respectively; p=0.079) and mCRP myocardial deposition (21% vs. 44%, respectively; p=0.026) were lower and IL-6 mRNA expression was higher (fold change: 407 vs. 326, respectively; p=0.376), although the difference in IL-6 mRNA expression was not statistically significant. Conclusion: IPC was associated with significantly decreased deposition of mCRP and with increased expression of IL-6 in myocardium damaged by IRI. The net cardioprotective effect of decreased mCRP deposition and increased IL-6 levels should be clarified in a further study.

Ultrasound and clinical findings in the metacarpophalangeal joint assessment of show jumping horses in training

  • Yamada, Ana Lucia M.;Pinheiro, Marcelo;Marsiglia, Marilia F.;Hagen, Stefano Carlo F.;Baccarin, Raquel Yvonne A.;da Silva, Luis Claudio L.C.
    • Journal of Veterinary Science
    • /
    • v.21 no.3
    • /
    • pp.21.1-21.14
    • /
    • 2020
  • Background: Physical exercise is known to cause significant joint changes. Thus, monitoring joint behavior of athletic horses is essential in early disorders recognition, allowing the proper management. Objectives: The aims of this study were to determine the morphological patterns, physical examination characteristics and ultrasound findings of show jumping horses in training and to establish a score-based examination model for physical and ultrasound follow-ups of metacarpophalangeal joint changes in these animals. Methods: A total of 52 metacarpophalangeal joints from 26 horses who were initially in the taming stage were evaluated, and the horses' athletic progression was monitored. The horses were evaluated by a physical examination and by B-mode and Doppler-mode ultrasound examinations, starting at time zero (T0), which occurred concomitantly with the beginning of training, and every 3 months thereafter for a follow-up period of 18 months. Results: The standardized examination model revealed an increase in the maximum joint flexion angles and higher scores on the physical and ultrasound examinations after scoring was performed by predefined assessment tools, especially between 3 and 6 months of evaluation, which was immediately after the horses started more intense training. The lameness score and the ultrasound examination score were slightly higher at the end of the study. Conclusions: The observed results were probably caused by the implementation of a training regimen and joint adaptation to physical conditioning. The joints most likely undergo a pre-osteoarthritic period due to work overload, which can manifest in a consistent or adaptive manner, as observed during this study. Thus, continuous monitoring of young athlete horses by physical and ultrasound examinations that can be scored is essential.

Development and validation of a computational multibody model of the elbow joint

  • Rahman, Munsur;Cil, Akin;Johnson, Michael;Lu, Yunkai;Guess, Trent M.
    • Advances in biomechanics and applications
    • /
    • v.1 no.3
    • /
    • pp.169-185
    • /
    • 2014
  • Computational multibody models of the elbow can provide a versatile tool to study joint mechanics, cartilage loading, ligament function and the effects of joint trauma and orthopaedic repair. An efficiently developed computational model can assist surgeons and other investigators in the design and evaluation of treatments for elbow injuries, and contribute to improvements in patient care. The purpose of this study was to develop an anatomically correct elbow joint model and validate the model against experimental data. The elbow model was constrained by multiple bundles of non-linear ligaments, three-dimensional deformable contacts between articulating geometries, and applied external loads. The developed anatomical computational models of the joint can then be incorporated into neuro-musculoskeletal models within a multibody framework. In the approach presented here, volume images of two cadaver elbows were generated by computed tomography (CT) and one elbow by magnetic resonance imaging (MRI) to construct the three-dimensional bone geometries for the model. The ligaments and triceps tendon were represented with non-linear spring-damper elements as a function of stiffness, ligament length and ligament zero-load length. Articular cartilage was represented as uniform thickness solids that allowed prediction of compliant contact forces. As a final step, the subject specific model was validated by comparing predicted kinematics and triceps tendon forces to experimentally obtained data of the identically loaded cadaver elbow. The maximum root mean square (RMS) error between the predicted and measured kinematics during the complete testing cycle was 4.9 mm medial-lateral translational of the radius relative to the humerus (for Specimen 2 in this study) and 5.30 internal-external rotation of the radius relative to the humerus (for Specimen 3 in this study). The maximum RMS error for triceps tendon force was 7.6 N (for Specimen 3).

Construction of a Novel Mitochondria-Associated Gene Model for Assessing ESCC Immune Microenvironment and Predicting Survival

  • Xiu Wang;Zhenhu Zhang;Yamin Shi;Wenjuan Zhang;Chongyi Su;Dong Wang
    • Journal of Microbiology and Biotechnology
    • /
    • v.34 no.5
    • /
    • pp.1164-1177
    • /
    • 2024
  • Esophageal squamous cell carcinoma (ESCC) is among the most common malignant tumors of the digestive tract, with the sixth highest fatality rate worldwide. The ESCC-related dataset, GSE20347, was downloaded from the Gene Expression Omnibus (GEO) database, and weighted gene co-expression network analysis was performed to identify genes that are highly correlated with ESCC. A total of 91 transcriptome expression profiles and their corresponding clinical information were obtained from The Cancer Genome Atlas database. A mitochondria-associated risk (MAR) model was constructed using the least absolute shrinkage and selection operator Cox regression analysis and validated using GSE161533. The tumor microenvironment and drug sensitivity were explored using the MAR model. Finally, in vitro experiments were performed to analyze the effects of hub genes on the proliferation and invasion abilities of ESCC cells. To confirm the predictive ability of the MAR model, we constructed a prognostic model and assessed its predictive accuracy. The MAR model revealed substantial differences in immune infiltration and tumor microenvironment characteristics between high- and low-risk populations and a substantial correlation between the risk scores and some common immunological checkpoints. AZD1332 and AZD7762 were more effective for patients in the low-risk group, whereas Entinostat, Nilotinib, Ruxolutinib, and Wnt.c59 were more effective for patients in the high-risk group. Knockdown of TYMS significantly inhibited the proliferation and invasive ability of ESCC cells in vitro. Overall, our MAR model provides stable and reliable results and may be used as a prognostic biomarker for personalized treatment of patients with ESCC.

Effects of Bupivacaine Pretreatment at the Periphery on the Expression of Mechanical Hyperalgesia in a Rat Model of Peripheral Neuropathy (백서의 말초신경 통증 모델에서 신경결찰 전 말초에 주입된 Bupivacaine이 기계적 통각과민의 발현에 미치는 영향)

  • Chung, Yong-Bo;Leem, Joong-Woo;Chung, Eun-Jung;Lee, Jung-Chan;Choi, Yoon
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.7-11
    • /
    • 2001
  • Background: Although several mechanisms of causalgia, which results from a partial injury to the peripheral nerve trunk, have been proposed, whether or not antidromic impulses from the injured neurons contribute to the development of the mechanical hyperalgesia has not been studied. The purpose of this experiment is was to investigate the role of antidromic impulses to the peripheral sensory receptor site on the development of mechanical hyperalgesia in a rat model of peripheral neuropathy. Methods: Rats were prepared with tight ligation of by tightly ligating the left fifth and sixth lumbar spinal nerves. The effect of bupivacaine pretreatment on the development of mechanical hyperalgesia was evaluated by injecting 0.5% bupivacaine (0.3 ml) into the plantar surface of the left hind paw before the skin incision was made. For the control group, normal saline (0.3 ml) was injected instead of bupivacaine. To measure the mechanical hyperalgesia, paw withdrawal thresholds were measured using a series of von Frey hairs. Mechanical hyperalgesia was measured a the day before, and 1, 2, 3, 4, 7, and 14 days after the surgery. Results: The control group showed decreased withdrawal thresholds from the day after the surgery (the values were $14.0{\pm}0.5$, $8.9{\pm}1.3$, $8.4{\pm}1.6$, $6.9{\pm}1.2$, $8.8{\pm}1.5$, $10.5{\pm}1.3$, and $8.6{\pm}1.3$ g; at -1, 1, 2, 3, 4, 7, and 14 days after the surgery, respectively). However, withdrawal thresholds of the bupivacaine-pretreated group showed increased withdrawal thresholds for three days after the surgery ($14.5{\pm}0.3$, $12.6{\pm}1.4$, $12.7{\pm}1.1$, $10.5{\pm}1.3$ g; at 1, 1, 2, 3 days after the surgery). Conclusions: Our result suggests that antidromic impulses to the peripheral sensory receptors are at least partly responsible for the initial development of mechanical hyperalgesia in a rat model of peripheral neuropathy.

  • PDF

Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.4
    • /
    • pp.251-262
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of implant tilting and the loading direction on the displacement and micromotion (relative displacement between the implant and bone) of immediately loaded implants by in vitro experiments and finite element analysis (FEA). Methods: Six artificial bone blocks were prepared. Six screw-type implants with a length of 10 mm and diameter of 4.3 mm were placed, with 3 positioned axially and 3 tilted. The tilted implants were $30^{\circ}$ distally inclined to the axial implants. Vertical and mesiodistal oblique ($45^{\circ}$ angle) loads of 200 N were applied to the top of the abutment, and the abutment displacement was recorded. Nonlinear finite element models simulating the in vitro experiment were constructed, and the abutment displacement and micromotion were calculated. The data on the abutment displacement from in vitro experiments and FEA were compared, and the validity of the finite element model was evaluated. Results: The abutment displacement was greater under oblique loading than under axial loading and greater for the tilted implants than for the axial implants. The in vitro and FEA results showed satisfactory consistency. The maximum micromotion was 2.8- to 4.1-fold higher under oblique loading than under vertical loading. The maximum micromotion values in the axial and tilted implants were very close under vertical loading. However, in the tilted implant model, the maximum micromotion was 38.7% less than in the axial implant model under oblique loading. The relationship between abutment displacement and micromotion varied according to the loading direction (vertical or oblique) as well as the implant insertion angle (axial or tilted). Conclusions: Tilted implants may have a lower maximum extent of micromotion than axial implants under mesiodistal oblique loading. The maximum micromotion values were strongly influenced by the loading direction. The maximum micromotion values did not reflect the abutment displacement values.