• Title/Summary/Keyword: Model scan method

Search Result 168, Processing Time 0.028 seconds

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

Curing Behavior and Morphology of DGEBA/NMA/2,4,6-tris(dimethylaminomethyl) phenol System (DGEBA/NMA/2,4,6-tris(dimethylaminomehyl)phenol 시스템의 경화거동 및 Morphology)

  • 김민영;김성호;최영선;김원호;황병선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.118-121
    • /
    • 2001
  • The investigation of cure kinetics and morphology studies on DGEBA/PEI/Anhydride system were performed by differential scanning calorimetry and scanning electron microscopy. Autocatalystic kinetics model was applied by isothermal scan test. Ozawa method and Kissinger method was applied by temperature scan. Activation energy was 95kJ/mol for neat DGEBA/NMA, 120kJ/mol for DGEBA/PEI(10p.h.r.)/NMA. The generation of secondary phase of PEI was observed and its size was grown up by increasing contents of PEI.

  • PDF

Algorithm for Fabricating 3D Breast Implants by Using MRI and 3D Scan Data (MRI와 3D 스캔 데이터를 이용한 3D 프린팅 유방 인공보형물의 제작 알고리즘)

  • Jeong, Young Jin;Choi, Dong Hun;Kim, Ku-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1385-1395
    • /
    • 2019
  • In this paper, we propose a method to fabricate a patient-specific breast implant using MRI images and 3D scan data. Existing breast implants for breast reconstruction surgery are primarily fabricated products for shaping, and among the limited types of implants, products similar to the patient's breast have been used. In fact, the larger the difference between the shape of the breast and the implant, the more frequent the postoperative side effects and the lower the satisfaction. Previous researches on the fabrication of patient-specific breast implants have used limited information based on only MRI images or on only 3D scan data. In this paper, we propose an algorithm for the fabrication of patient-specific breast implants that combines MRI images with 3D scan data, considering anatomical suitability for external shape, volume, and pectoral muscle. Experimental results show that we can produce precise breast implants using the proposed algorithm.

Anlaysis of Eukaryotic Sequence Pattern using GenScan (GenScan을 이용한 진핵생물의 서열 패턴 분석)

  • Jung, Yong-Gyu;Lim, I-Suel;Cha, Byung-Heun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.113-118
    • /
    • 2011
  • Sequence homology analysis in the substances in the phenomenon of life is to create database by sorting and indexing and to demonstrate the usefulness of informatics. In this paper, Markov models are used in GenScan program to convert the pattern of complex eukaryotic protein sequences. It becomes impossible to navigate the minimum distance, complexity increases exponentially as the exact calculation. It is used scorecard in amino acid substitutions between similar amino acid substitutions to have a differential effect score, and is applied the Markov models sophisticated concealment of the transition probability model. As providing superior method to translate sequences homologous sequences in analysis using blast p, Markov models. is secreted protein structure of sequence translations.

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.4
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.

A Study of Nondestructive Evaluation Using Scan type Magnetic Camera

  • Hwang, Ji-Seong;Lee, Jin-Yi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1830-1835
    • /
    • 2005
  • It is important to estimate the distribution of intensity of a magnetic field for application of magnetic method to industrial nondestructive evaluation. Magnetic camera provides the distribution of a quantitative magnetic field with homogeneous lift-off and same spatial resolution. And it is possible to interpret the distribution of the magnetic field when the dipole model is introduced. This study introduces the numerical and experimental considering of the quantitative evaluation of several size and shapes of the cracks using the magnetic field images of the scan type magnetic camera.

  • PDF

A Study of Utilizing 2D Photo Scan Technology to Efficiently Design 3D Models (2D 포토 스캔 기술을 활용한 효율적인 3D 모델링 제작방법 연구)

  • Guo, Dawei;Chung, Jeanhun
    • Journal of Digital Convergence
    • /
    • v.15 no.7
    • /
    • pp.393-400
    • /
    • 2017
  • Generally, in special effect video and 3D animation design process, character and background's 3D model is built by 3D program like MAYA or 3DS MAX. But in that manual modeling mode, model design needs much time and costs much money. In this paper, two experimental groups are set to prove use 2D photo scan modeling mode to build 3D model is effective and advanced. The first experimental group is modeling the same object by different experimental setting. The second experimental group is modeling the same background by different experimental setting. Through those two experimental groups, we try to find an effective design method and matters need attention when we use photo scan design mode. We aim to get the model from whole experiment and prove photo scan modeling mode is effective and advanced.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Automated Silhouette Extraction Method for Generating a Blueprint from 3D Scan Data of Cultural Asset (문화재의 3D 스캔 데이터로부터 도면을 생성하기 위한 자동화된 실루엣 추출 방법)

  • Jung, Jung-Il;Cho, Jin-Soo;WhangBo, Tae-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.12
    • /
    • pp.10-19
    • /
    • 2008
  • In this paper, we propose an automated silhouette extraction method that can effectively extract inner-patterns and silhouettes from 3D scan data of cultural asset. First of all, after creating the edge list of 3D vector data, we decide contour edge and crease edge according to viewpoint. In the next step, after extracting surface silhouette by investigating the vector variation of adjacent faces in crease edge, we finally extract the contour silhouette and surface silhouette for generating the blueprint of cultural asset. To evaluate the performance of the proposed silhouette extraction method, we performed experiments of silhouette extraction using a traditional tile model, a car model and a stone monument model. Comparing with the conventional threshold-based silhouette extraction method, the proposed method extracted more distinct and clear surface silhouettes and inner-patterns by effectively removing meaningless edges, such as noise.