• Title/Summary/Keyword: Model pump

Search Result 934, Processing Time 0.023 seconds

Determination of proper ground motion prediction equation for reasonable evaluation of the seismic reliability in the water supply systems (상수도 시스템 지진 신뢰성의 합리적 평가를 위한 적정 지반운동예측식 결정)

  • Choi, Jeongwook;Kang, Doosun;Jung, Donghwi;Lee, Chanwook;Yoo, Do Guen;Jo, Seong-Bae
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.9
    • /
    • pp.661-670
    • /
    • 2020
  • The water supply system has a wider installation range and various components of it than other infrastructure, making it difficult to secure stability against earthquakes. Therefore, it is necessary to develop methods for evaluating the seismic performance of water supply systems. Ground Motion Prediction Equation (GMPE) is used to evaluate the seismic performance (e.g, failure probability) for water supply facilities such as pump, water tank, and pipes. GMPE is calculated considering the independent variables such as the magnitude of the earthquake and the ground motion such as PGV (Peak Ground Velocity) and PGA (Peak Ground Acceleration). Since the large magnitude earthquake data has not accumulated much to date in Korea, this study tried to select a suitable GMPE for the domestic earthquake simulation by using the earthquake data measured in Korea. To this end, GMPE formula is calculated based on the existing domestic earthquake and presented the results. In the future, it is expected that the evaluation will be more appropriate if the determined GMPE is used when evaluating the seismic performance of domestic waterworks. Appropriate GMPE can be directly used to evaluate hydraulic seismic performance of water supply networks. In other words, it is possible to quantify the damage rate of a pipeline during an earthquake through linkage with the pipe failure probability model, and it is possible to derive more reasonable results when estimating the water outage or low-pressure area due to pipe damages. Finally, the quantifying result of the seismic performance can be used as a design criteria for preparing an optimal restoration plan and proactive seismic design of pipe networks to minimize the damage in the event of an earthquake.

Groundwater Flow Analysis in Fractured Rocks Using Zonal Pumping Tests and Water Quality Logs (구간양수시험과 수질검층자료에 의한 균열암반내 지하수 유동 분석)

  • Hamm, Se-Yeong;Sung, Ig-Hwan;Lee, Byeong-Dae;Jang, Seong;Cheong, Jae-Yeol;Lee, Jeong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.411-427
    • /
    • 2006
  • This study aimed to recognize characteristics of groundwater flow in fractured bedrocks based on zonal pump-ing tests, slug tests, water quality logs and borehole TV camera logs conducted on two boreholes (NJ-11 and SJ-8) in the city of Naju. Especially, the zonal pumping tests using sin91e Packer were executed to reveal groundwater flow characteristics in the fractured bedrocks with depth. On borehole NJ-11, the zonal pumping tests resulted in a flow dimension of 1.6 with a packer depth of 56.9 meters. It also resulted in lower flow dimensions as moving to shallower packer depths, reaching a flow dimension of 1 at a 24 meter packer depth. This fact indicates that uniform permissive fractures take place in deeper zones at the borehole. On borehole SJ-8, a flow dimension of 1.7 was determined at the deepest packer level (50 m). Next, a dimension of 1.8 was obtained at 32 meters of packer depth, and lastly a dimension of 1.4 at 19 meters of packer depth. The variation of flow dimension with different packer depths is interpreted by the variability of permissive fractures with depth. Zonal pumping tests led to the utilization of the Moench (1984) dual-porosity model because hydraulic characteristics in the test holes were most suitable to the fractured bedrocks. Water quality logs displayed a tendency to increase geothermal temperature, to increase pH and to decrease dissolved oxygen. In addition, there was an increasing tendency towards electrical conductance and a decreasing tendency towards dissolved oxygen at most fracture zones.

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF