• Title/Summary/Keyword: Model checking

Search Result 569, Processing Time 0.026 seconds

Analysis of Posting Preferences and Prediction of Update Probability on Blogs (블로그에서 포스팅 성향 분석과 갱신 가능성 예측)

  • Lee, Bum-Suk;Hwang, Byung-Yeon
    • Journal of KIISE:Databases
    • /
    • v.37 no.5
    • /
    • pp.258-266
    • /
    • 2010
  • In this paper, we introduce a novel method to predict next update of blogs. The number of RSS feeds registered on meta-blogs is on the order of several million. Checking for updates is very time consuming and imposes a heavy burden on network resources. Since blog search engine has limited resources, there is a fix number of blogs that it can visit on a day. Nevertheless we need to maximize chances of getting new data, and the proposed method which predicts update probability on blogs could bring better chances for it. Also this work is important to avoid distributed denial-of-service attack for the owners of blogs. Furthermore, for the internet as whole this work is important, too, because our approach could minimize traffic. In this study, we assumed that there is a specific pattern to when a blogger is actively posting, in terms of days of the week and, more specifically, hours of the day. We analyzed 15,119 blogs to determine a blogger's posting preference. This paper proposes a method to predict the update probability based on a blogger's posting history and preferred days of the week. We applied proposed method to 12,115 blogs to check the precision of our predictions. The evaluation shows that the model has a precision of 0.5 for over 93.06% of the blogs examined.

Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

A Comparative Study on the Methods for Weighting the Dimensions of Customer Satisfaction with Importance Perceived by Customers (고객만족도 조사도구의 차원별 가중치 부여방법 비교)

  • Kang, Myunggeun;Cho, Woohyun;Lee, Sunhee;Choi, Kuison;Mooon, Kitae
    • Quality Improvement in Health Care
    • /
    • v.7 no.2
    • /
    • pp.230-242
    • /
    • 2000
  • Background : The measuring instruments for customer satisfaction in hospitals are often composed of some dimensions reflecting the conceptive complexity of them. Then, overall satisfaction would be expected to be equal the 'weighted' sum of scores by dimensions because the importance rated by customers may be different across the dimensions. But the issue of how to weight the dimensions with importance is not yet solved. We examined 3 sets of weighting methods as to make effect on predictive power against overall satisfaction. Methods : We conducted a survey included 483 subjects who had visited or admitted to a university hospital, using the short form questionnaire being developed by The Korean Society of Quality Assurance in Health Care for out-patient and in-patient. By using a multiple linear regression model, we compared among changes of explanatory powers against overall satisfaction as dependent variable after weighting 4 dimensions of the survey questionnaire as independent variables with importance scores of dimensions perceived by consumers. And we compared the feasibility of each weighting, methods by checking missing cases. Results : There were no weighting methods increasing the explanatory power after applying them. The method of absolute scoring was found higher explanatory-power than others, but this finding had no statistical significance. Regarding the number of missing value, method of absolutely scoring had the least cases. Conclusion : Our findings suggested that weighting the dimensions with importance might have little significance in the cases of scales having items highly correlated, such as consumers' satisfaction. Though asking with items to be answered absolutely, customers might be rating relatively in some degree and this method produced least missing cases. Considering these points, in the cases when weighting the dimensions with importance would be required, we suggest that weighting method by absolute scoring might be better than others.

  • PDF

KorLexClas 1.5: A Lexical Semantic Network for Korean Numeral Classifiers (한국어 수분류사 어휘의미망 KorLexClas 1.5)

  • Hwang, Soon-Hee;Kwon, Hyuk-Chul;Yoon, Ae-Sun
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.1
    • /
    • pp.60-73
    • /
    • 2010
  • This paper aims to describe KorLexClas 1.5 which provides us with a very large list of Korean numeral classifiers, and with the co-occurring noun categories that select each numeral classifier. Differently from KorLex of other POS, of which the structure depends largely on their reference model (Princeton WordNet), KorLexClas 1.0 and its extended version 1.5 adopt a direct building method. They demand a considerable time and expert knowledge to establish the hierarchies of numeral classifiers and the relationships between lexical items. For the efficiency of construction as well as the reliability of KorLexClas 1.5, we use following processes: (1) to use various language resources while their cross-checking for the selection of classifier candidates; (2) to extend the list of numeral classifiers by using a shallow parsing techniques; (3) to set up the hierarchies of the numeral classifiers based on the previous linguistic studies; and (4) to determine LUB(Least Upper Bound) of the numeral classifiers in KorLexNoun 1.5. The last process provides the open list of the co-occurring nouns for KorLexClas 1.5 with the extensibility. KorLexClas 1.5 is expected to be used in a variety of NLP applications, including MT.

Simplification of State Invariant with Mixed Reachability Analysis (혼합 도달성 분석을 이용한 상태 불변식의 단순화)

  • 권기현
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.3_4
    • /
    • pp.212-218
    • /
    • 2003
  • State invariant is a property that holds in every reachable state. It can be used not only in understanding and analyzing complex software systems, but it can also be used for system verifications such as checking safety, liveness, and consistency. For these reasons, there are many vital researches for deriving state invariant from finite state machine models. In previous works every reachable state is to be considered to generate state invariant. Thus it is likely to be too complex for the user to understand. This paper seeks to answer the question `how to simplify state invariant\ulcorner`. Since the complexity of state invariant is strongly dependent upon the size of states to be considered, so the smaller the set of states to be considered is, the shorter the length of state invariant is. For doing so, we let the user focus on some interested scopes rather than a whole state space in a model. Computation Tree Logic(CTL) is used to specify scopes in which he/she is interested. Given a scope in CTL, mixed reachability analysis is used to find out a set of states inside it. Obviously, a set of states calculated in this way is a subset of every reachable state. Therefore, we give a weaker, but comprehensible, state invariant.

Improvement of a Verified Secure Key Distribution Protocol Between RFID and Readers (RFID와 리더간의 안전성이 검증된 키 분배 프로토콜의 개선)

  • Bae, Woo-Sik;Lee, Jong-Yun
    • The KIPS Transactions:PartC
    • /
    • v.18C no.5
    • /
    • pp.331-338
    • /
    • 2011
  • The RFID system includes a section of wireless communication between the readers and the tags. Because of its vulnerability in terms of security, this part is always targeted by attackers and causes various security problems including the leakage of secret and the invasion of privacy. In response to these problems, various protocols have been proposed, but because many of them have been hardly implementable they have been limited to theoretical description and theorem proving without the accurate verification of their safety. Thus, this study tested whether the protocol proposed by Kenji et al. satisfies security requirements, and identified its vulnerabilities such as the exposure of IDs and messages. In addition, we proposed an improved RFID security protocol that reduced the number of public keys and random numbers. As one of its main characteristics, the proposed protocol was designed to avoid unnecessary calculations and to remove vulnerabilities in terms of security. In order to develop and verify a safe protocol, we tested the protocol using Casper and FDR(Failure Divergence Refinements) and confirmed that the proposed protocol is safe in terms of security. Furthermore, the academic contributions of this study are summarized as follows. First, this study tested the safety of a security protocol through model checking, going beyond theorem proving. Second, this study suggested a more effective method for protocol development through verification using FDR.

The Study of the Validity Test on the Self-monitoring Scale (자기 검색척도(Self-Monitoring Scale)의 타당성 검정에 관한 연구)

  • 이선아
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.751-759
    • /
    • 1998
  • The study of the validity test on the self-monitoring scale for nurses In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of the self-monitoring scale. The self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen(1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity were found in the previous research findings. It is also important to note that Snyder's self-monitoring scale did not factor-load at over. 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lacks convergent validity as the sub-factors of the scale failed to prove its uni-dimensionality. The A self-monit oring scale not only fail to overcome the problems of Snyder's self-monitori ng scale but even lost the attractiveness of the self-monitoring scale. In this study it was also found that the A self-monitoring scale was not classified in either in a two or three-factor classification as hypothesized. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used and has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were class ified and loaded as expected. Reliability was also proven by checking Cronbach's α for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound : however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original nor the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over. 30, too high for the two factors in the test results of Factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

Study of the Validity Test on the Self-monitoring Scale for Primi-Gravida (초임부를 대상으로 한 자가검색도 척도의 타당도 비교)

  • Lee, Seon-Ah
    • Women's Health Nursing
    • /
    • v.4 no.2
    • /
    • pp.173-186
    • /
    • 1998
  • In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen (1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity was found in the previous research findings. It is also important to note that Snyder's self-monitoring scale, did not factor-load at over 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lack convergent validity as the sub-factors of the scale fail to prove its uni-dimensionality. The A self-monitoring scale not only fail to overcome the problems of Snyder's self-monitoring scale but even lost the attractiveness of the self-monitoring scale. In this study, it was also found that the A self-monitoring scale was not classified as hypothesized in either in a two or three-factor classification. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used but also has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study 1. was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were classified and loaded as expected. Reliability was also proven by checking Cronbach's alpha for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound ; however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original or the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over .30, too high for the two factors in the test results of factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

Design and Implementation of the u-Health Care Services in the Life Environment (생활환경 기반 u-건강관리서비스 설계 및 구현)

  • Hong, In-Hwa;Kim, Ju-Young;Choi, Ho-Chun;Kim, Chan-Gyu;Jung, Kwang-Mo;Kim, Nam-Il;Kang, Jeong-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.107-118
    • /
    • 2011
  • This paper shows a u-Health management system in user's Life environment, which is different from previous ones by enterprises. It's designed for users(citizens) and service provider(especially providing medical service). This paper is discussing on the proof on the service model being operated near the Tancheon stream in the city of Sung-nam. To maximize users' satisfaction, this service has been designed on four disciplines(so easy, so simple, well-customized, funny feedback) in the viewpoint for users. Its algorithm has 4 levels which are measurement, prescription, monitoring and feedback. In the system. there are HCBs(health check boothes) checking out status and assessment of users, customized health prescription customized a health management service prescription engine, exercise programs customized on exercise equipments near the stream and monitoring system.

Relations between class distracting factors and class satisfaction of dental technology students (치기공과 학생의 수업 방해 요인과 수업 만족도와의 관계)

  • Kwon, Soon-Suk;Lee, Hye-Eun
    • Journal of Technologic Dentistry
    • /
    • v.39 no.4
    • /
    • pp.263-273
    • /
    • 2017
  • Purpose: This study aimed to explore the relations between class distracting factors and class satisfaction of the dental technology students and then provide a primary data to help further related studies and develop educational programs with which instructors can efficiently manage their classroom. Methods: For this study we have conducted a survey started from the beginning of May 2017 to the end of June. The subjects of the survey were Dental Technology students of D-city, K-city, W-city, selected by random sampling method. The questionnaire was self-administrated and 437 valid results were chosen for our analysis among 450 distributed questionnaires. Results: The results of the research was as follows. Firstly, The overall average point of class distracting factors was 2.5 point. The environmental factors were the highest point as 2.59 and as for the subcategories tiredness and drowsiness was the highest point as 2.76. Secondly, The overall average point of class satisfaction turned out 3,88 point and compliance with class and attitude factors gained the highest point as 4.06. Of the subcategories strict roll checking was the highest point as 4.17. Thirdly, As for class distracting factors from general characteristics a statistical significance was shown as follows; 'instructor factor'(p<.01), 'learner factor'(p<.05), 'total class distracting factor'(p<.05) in the area of gender, 'environmental factor'(p<.001), 'total class distracting factor'(p<.01), 'learner factor'(p<.05), 'instructor factor'(p<.05) in the area of gender 'learner factor'(p<.001), 'instructor factor'(p<.001), 'environmental factor'(p<.001), 'total class distracting factor'(p<.01) in the area of class grade, 'environmental factor'(p<.05) in GPA. Fourthly, A statistical significance, a negative correlation (p<.01) were shown between class distracting factors and class satisfaction. Class distracting factor that especially affects the class satisfaction was instructor factor(p<.001) and the explanatory power of the model turned out 14.7%, which was statistically meaningful (p<.001). Conclusion : Results of this study reveal that instructor factor is the key to class satisfaction of the students. So it is crucial that the instructor faithfully prepare for the class to reinforce the students' learning. Additionally further studies should be followed with more subjects and newer perspectives to develop innovative teaching methodology.