• Title/Summary/Keyword: Mode value

Search Result 1,619, Processing Time 0.025 seconds

Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses

  • Eun Ji Lee;Yun-Woo Chang
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1045-1054
    • /
    • 2020
  • Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.

Design of a Bidirectional Adaptive Coupler for Spread Spectrum Power Line Communications (대역 확산 전력선 통신을 위한 양방향 적응 결합기 설계)

  • Yu, Young-Gyu;Woo, Dae-Ho;Choi, Seok-Woo;Kim, Dong-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.623-628
    • /
    • 2007
  • This paper presents the new power line coupler which is applicable to spread spectrum power line communications. The proposed coupler maintains the adequate value of a capacitor between the transmitter mode and the receiver mode using a switch. In the transmit mode, the relatively high value of the capacitor is chosen to minimize the attenuation of transmitted signals. In the receiver mode, the value of the capacitor is chosen to be small enough so that the coupler attenuates power line noises. This coupler reduced the magnitude distortion due to having a high Q value and the power consumption caused by the AC current flowing into the capacitor. The simulation and measurement results show the improved performance in the transmitter and receiver mode, respectively.

A Study on Development of SCARA robot Using Fuzzy-Sliding mode control (퍼지-슬라이딩 모드를 이용한 스카라 로보트의 제어에 관한 연구)

  • 고석조;이민철;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.241-245
    • /
    • 1995
  • This paper shows that the proposed fuzzy-sliding mode for SCARA robot control could reduce chattering problemed in sliding mode control and is robust against parameter uncertainties. It was very small quantities of chattering in the fuzzy-sliding mode control conpared with that in sliding mode control with two dead-band. In here, the sliding mode control with two dead-band is the method to reduce some chattering by changing into a continuous variable lower control input gain when a state value in pahase palne converged sithin two dead-band. But, the fuzzy-sliding mode control for more reducing chattering is the method to change control input by slicing mode into that by fuzzy rule within two dead-band. Simulations show that the effect of reducing chattering by the fuzzy-sliding mode is superior to sliding mode control with two dead-band.

  • PDF

Analysis of Wear Proccess in Sliding Contact by X-ray Diffraction (X선회절에 의한 미끄럼접촉시 발생하는 마모과정의 해석(제1보 : 저경도강의 적용))

  • 이한영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.19-24
    • /
    • 1999
  • Understanding of wear mode and prediction of wear rate of parts in sliding contact are very important in field of meterial design relating with wear resistant. This paper has been undertaken to analyze the possibility of elucidation of wear mode and prediction of wear rate for annealed steel in sliding contact using the X-ray diffraction. The sliding wear test with various velocities using pin-on-disc machine and the X-ray diffraction test on the worn surface have been carried out. The results have been shown that the magnitude of residual stress and half-value breadth on the worn surface have a good correlation with wear mode. The difference between before and after test of half-value breadth on worn surface has been shown to be exponential relation with wear rate in the same wear mode.

  • PDF

A Study on the Interlaminar Fracture Toughness of Glass Fiber Reinforced Plastic Comosites (GFRP 복합재료의 층간파괴인성치에 관한 연구)

  • 박기호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.4
    • /
    • pp.410-420
    • /
    • 1999
  • The value of the mode I interlamina fracture toughness, GIC, is calculated by experimental compliance method, modified compliance method and beam theory. The value of the mode II interlamina fracture toughness, GIC, is evaluated by beam method, theory beam theory and compliance method. This paper describes the effect of load pint displacement rate and speicimen geometries for mode I and II interlaminar fracture toughness of glass fiber reinforced plastic composites by using double cantilever beam (DCB) and end notched flexure (ENF) specimen. For the load point displacement rate of increases whereas the value of 2,6 and 10 mm/min the value of GIC decrease as load point displacement rate increases whereas the value of GIC is found to be no significant effect. The value of GIC decreases as initial crack length increases. The fractured surface of the DCB and ENF samples are examined by scanning electron microscopy (SEM).

  • PDF

Threshold detection technique for code acquisition using maximum mismatched correlation value (부정합된 최대 상관값을 이용한 초기 동기 임계치 결정 기법)

  • 유영환;김종헌;강성철;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.7
    • /
    • pp.1803-1813
    • /
    • 1996
  • This paper describes an automatic threshold decision using a maximum mismatched correlation value in the direct sequence spread spectrum (DS-SS) system. For received PN codes with different single-to-noise ratio (SNR), this scheme is able to detect a desired threshold value in the search mode, i.e. a maximum mismstched correlation value, so that value is utilized as a threshold for the verification mode. Performance of the proposed scheme in both the additive white gaussian noise (AWGN) and frequency-selective Rayleigh fading channels is analyzed through the Monte Carlo simulation. And hardware implementation of this scheme using a DSP processor is demonstrated. The proposed acquisition shceme is compared to the conventional constant threshold (CT) scheme, and significant improvement of performance is shown. Analysis of system performance in the verification mode is presented, and key quantities such as the false alarm probability and the detection probability are derived in a AWGN channel.

  • PDF

The Study of Effectiveness of Volume Mode in Pediatric CT (소아 전산화단층촬영에서 Volume Mode의 유용성 연구)

  • Park, Yun;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.425-431
    • /
    • 2014
  • The purpose of this study is to analyze dose comparison and image quality evaluation according to Volume and Helical mode using ATOM Phantom. It is to actively use the Volume mode in pediatric CT examinations. There was no significant difference with Helical and Volume in the value of Noise, HU, SNR(p>0.05). All dose values was no statistical difference(p>0.05). In the value of DLP and effective dose by part, Volume mode was measured lower than Helical mode. For qualitative analysis, by scan parameter helical mode showed respectively 2.6, 3.3, 4.36 and Volume mode indicated 2.8, 3.64, 4.44 point. Image evaluation for the follow-up, Helical mode and Volume mode were respectively 3.8 and 3.83. In fact, There was no significant difference. In CT scans in children under 5 years, because 640-MDCT Volume scan dose compared with Helical mode is lower and there is no significant difference with two modes in the image quality, 640-MDCT Volume scan is thought to be useful for pediatric CT scans.

The Effects of Assertiveness Traning and Value Clarification Training on Nurse's Conflict and Conflict Management Mode (주장훈련과 가치명료화훈련이 간호사의 갈등정도와 갈등관리 양식에 미치는 효과)

  • Park, Sang-Yeon
    • Journal of muscle and joint health
    • /
    • v.2 no.1
    • /
    • pp.41-72
    • /
    • 1995
  • The purpose of this study is to examine the effects of assertiveness training and value clarification training on nurse's conflict and conflict management mode. Fifty seven registered nurses participated in the study ; they were employed by three general hospital located in Daegu, Korea. The study employs two treatment groups. The assertiveness training group consisted of subjects who participated in 90-120 minutes sessions of assertiveness training nine times over five weeks. The other treatment group, was adiministed nine, 90-120 minutes sessions of value clarification during the same period. For the control group, nursing subjects were appointed the training after five weeks. Pre-test evaluation were administered to all subjects in three groups prior to one week of the treatment. Role conflict Inventory-general(RCI-G) and Communication Conflict Inventory-general (CCI-G) measure nurse's conflict management mode. Post-test evaluation were administered to all subjects in three groups two weeks after the last session by Role Conflict Inventory-Specific(RCI-S), Communication Conflict Inventory-Specific (CCI-S), Management Model-Specific(CMMI-S). The analysis of variance(ANOVA) and covariance(ANCOVA) on gain scores were running the SPSS program. In order to test statistical differences among mean scores of the scales obtained after treatment, multiple comparisons were carried out by Turkey method. Conclusions obtained from the results are as follows. 1. The assertiveness training and the value clarification training were effective in decreasing the nurse's role conflict. The value clarification was more effective than the assertiveness training in decreasing the nurse's role conflict. 2. Both assertiveness training and value clarification training were effective in decreasing nurse's communication conflict. There was, however, no differences between assertiveness training and value clarification training in decreasing the nurse's communication conflict. 3. The assertiveness training and the value clarification training were quite effective in compromizing and collaborating conflict management mode, to reducing the withdrawl and accomodate, force and accomodate conflict management mode to conflict. There was no difference in the effectiveness of assertiveness training and value clarification. In assessing the effects of the treatments, this study employed different measurements. It is unclear whether the measurement affected the test results. It is worth conducting a further test using the same measurements. The results of future studies can be compared with those of this study. The homogeneity of the control group and treatment group is questionable. Futher studies may employ homogeneous sample group to evaluate whether the sample characteristics bias the test results. Assertiveness training or value clarification training for nurses can be utilized in nursing intervention.

  • PDF

A Resonant Mode Identification in Cylindrical Cavity Resonators with Concentric-rod using Non-decaying Mode Analysis (유전체 봉이 삽입된 원통형 공동 공진기에서의 non-decaying 모드 해석을 이용한 공진 모드 구분)

  • Lee, Won-Hui;Kim, Tai-Shin;Kang, Min-Woo;Koo, Kyung-Wan;Hur, Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.1069-1072
    • /
    • 2001
  • We described a method resonant mode identification in dielectric-rod loaded cylindrical cavity resonators. Resonant frequency of dielectric loaded cavity is calculated by analyzing the characteristic equation. The characteristic equation is solved by using the ContourPlot graph of Mathematica. As the result of comparing calculation value and experimental value of resonant frequencies, we know that the field representation of non-decaying mode is exact. The contour graph method is not a method using approximated representation of electromagnetic field variation at the outer area of dielectric in the resonators but a method using exact representation.

  • PDF

A study on the Development of TCM Urban and Rural mode for Environmental Impact Assessment (환경영향평가를 위한 도시형과 교외형 TCM 개발에 관한 연구)

  • Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.1
    • /
    • pp.63-70
    • /
    • 1998
  • TCM has been used for many environmental impact assessments in Korea. But there was reported that an error was found in area source calculation of original TCM and modified. In this study, TUM(TCM-urban mode) and TRM(TCM-rural mode) were developed for urban and rural area by modification of original TCM. McElroy-Pooler dispersion parameter was used for area and point source in TUM, Pasquill-Gifford parameter was used for area and point source in TRM. And Irwin's vertical wind speed profile exponents were used for TUM and TRM. Then predicted value by TUM, TRM and a value from the same area and point data by CDM2, ISCLT3 were compared. And it was found that predicted value from point source by TUM, TRM was very similar to a value by CDM2, ISCLT3, and predicted value from area source by TRM was similar to a value by CDM2, ISCLT3. But predicted value from area: source by TUM was an half lower than a value by CDM2, ISCLT3.

  • PDF