A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

Improved Space Vector Modulation Strategy for AC-DC Matrix Converters

  • Liu, Xiao;Zhang, Qingfan;Hou, Dianli;Wang, Siyao
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.647-655
    • /
    • 2013
  • In this paper, an approach to reduce the common-mode voltage and to eliminate narrow pulse for implemented AC-DC matrix converters is presented. An improved space vector modulation (SVM) strategy is developed by replacing the zero space vectors with suitable pairs of active ones. Further, while considering the commutation time, the probability of narrow pulse in the conventional and proposed SVM methods are derived and compared. The advantages of the proposed scheme include: a 50% reduction in the peak value of the common-mode voltage; improved input and output performances; a reduction in the switching loss by a reduced number of switching commutations and a simplified implementation via software. Experimental results are presented to demonstrate the correctness of the theoretical analysis, as well as the feasibility of the proposed strategy.

FFS 모드에서 표면 엥커링에너지에 따른 전기광학특성의 연구 (A Study on Electro-optical Characteristics Dependent on Surface Anchoring Energy in the Fringe-field Switching Mode)

  • 유인호;총첸신;장원근;이명훈;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.1028-1032
    • /
    • 2005
  • Liquid crystal (LC) alignment using a photoalignment method by irradiation of polarized ultraviolet (UV) on an alignment layer has been investigated. Photoalignment method exhibits weaker anchoring energy than rubbing method so that we have studied electro-optic characteristics of fringe-field switching (FFS) mode with alignment layers using the photo and rubbing alignment methods. The cell using photo alignment layer shows lower threshold and operation voltage than those using rubbed alignment layer. Also, the former method shows higher transmittance than that of the latter.

이중 모드 스윗칭 억세스 프로토콜을 이용한 고속 근거리 통신망의 성능평가 (Performance Evaluation of a High-Speed LAN using a Dual Mode Switching Access Protocol)

  • 주기호
    • 한국통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.2620-2633
    • /
    • 1996
  • In this paper, a new high-speed local area network using a dual mode switching access (DMSA) protocol implemented on a dual unidirectional bus is described. By utilizing the implicit positionalordering of stations on a unidirectional bus, the proposed system switches between random access mode and the token access model withoug unnecessary delay. Therefore, unlike other hybrid systems such as Buzz-net and Z-net, DMSA does not show a rapid degradation in performance as the load increases. We obtain the average channel utilization and the average access delay by using a simplified analytic model. The numerical results obtained via analysis are compared to the simulation resuls for a partial validation of the approximate model. The performance characteristics of DMSA are superior delay-throughput characteristics at light and medium loads, compared to compared to other LAN systems, and the capability of providing a single active station with full capabity of the channel.

  • PDF

유전율 이방성이 양인 액정을 이용한 FFS모드의 절연층 두께에 따른 전기 광학 특성 연구 (Study on Electro-Optic Characteristics Dependent on Passivation Layer Thickness in the FFS mode using a Liquid Crystal with Positive Dielectric Anisotropy)

  • 이지연;박상현;오상민;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.485-486
    • /
    • 2005
  • Fringe-field switching mode which has a horizontal and vertical electric field exhibits high transmittance and wide viewing angle characteristics. In the FFS mode, a passivation layer between common and pixel electrodes exists, which functions as preventing current leakage of fringe-field. In this paper, we have studied LC behavior, transmittance and operating voltage characteristics with applied voltage as a function of the passivation layer thickness and defined optimal value of the layer to be about $0.5{\mu}m$.

  • PDF

FFS 모드에서 표면 앵커링 에너지에 따른 전기광학특성의 연구 (Effect of Surface anchoring energy on the Electro-Optical Characteristics in the Fringe-Field Switching mode)

  • 유인호;총첸신;장원근;이명훈;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.118-122
    • /
    • 2005
  • Liquid crystal (LC) alignment using a photoalignment method by irradiation of polarized ultraviolet (UV) on an alignment layer has been investigated. Photoalignment method exhibits weaker anchoring energy than rubbing method so that we have studied electro-optic characteristics of fringe-field switching (FFS) mode with alignment layers using the photo and rubbing alignment methods. The cell using photo alignment layer shows lower threshold and operation voltage than those using rubbed alignment layer. Also. the former method shows higher transmittance than that of the latter.

  • PDF

HMIPv6를 기반으로 한 무선 랜과 이동 애드 혹 네트워크 간의 인터네트워킹 기법 (Internetworking strategy between MANET and WLAN for Extending Hot-Spot of WLAN based on HMIPv6)

  • 이혜원;문영성
    • 한국정보과학회논문지:정보통신
    • /
    • 제33권1호
    • /
    • pp.38-48
    • /
    • 2006
  • 무선 랜의 영역 확장을 위해서 무선 랜과 유사한 2계층 프로토콜(1)을 사용하는 이동 애드 혹 네트워크의 인터네트워킹 기법을 (2)에서 제안하고 있다. 이 기법은 무선 랜 확장을 위한 UMTS (Universal Mobile Telecommunications Systems)와 무선 랜의 인터네트워킹 기법(3-4)에 비해 물리 및 논리적인 특성이 유사하기 때문에 상대적으로 낮은 오버헤드와 지연을 갖는다는 장점이 있다. 애드 흑과 무선 랜간의 인터네트워킹을 위해 (2)가 제안하고 있는 모드 변환 알고리즘은 시그널 강도만을 고려하여 핸드오프를 결정하기 때문에 상이한 시그널을 수신하는 영역에 지그재그로 이동하는 경우 빈번한 핸드오프를 야기 시킬 수 있다. 또, 무선 랜에서의 이동성 지원이 MIPv6 프로토콜을 기반으로 하고 있어서 핸드오프시 높은 지연을 갖고 시그널 메시지 교환으로 인한 오버헤드가 크다. 본 논문에서는 (2)에서 제안하는 스위칭 기법을 수정 및 보완함으로써 이동 노드가 HMIPv6를 기반으로 하고 있는 무선 랜의 범위를 벗어나 난청지역(dead-spot)에 진입했을 때 무선 랜 영역의 확장을 위해서 무선 랜과 이동 애드 혹 네트워크간의 최적화된 인터네트워킹 방안을 제안한다. (2)에서 발생할 수 있는 핸드오프 핑퐁문제를 적응적인 임계치를 반영함으로써 해결하였다. 특히, 무선 랜에서 이동성 지원을 위한 HMIPv6 프로토콜과 병립되어 사용될 수 있는 OLSR 프로토콜을 이동 애드 혹 네트워크에서 적용하였다. 총 오버헤드 시간을 구하고 실험과 시뮬레이션을 통해 제안된 스위칭 방식이 기존의 방식보다 성능이 우수함을 확인하였다.

고조파 저감을 위한 소프트 스위칭 승압형 PFC컨버터의 특성해석 (Characteristics analysis of PFC boost converter with soft switching for harmonics reduction)

  • 김봉규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.150-154
    • /
    • 2000
  • This paper proposes PFC boost converter with soft switching for harmonics decrement and analyzes characteristics of PFC boost converter. In this technique power factor correction(PFC) is usually obtained by operating the PFC stage in the discontinuous current mode(DCM) Switching devices are operated for reducing current stress and electronical noise. As a result eliminate 3rd harmonic component and high power factor(PF) of the input line are verified by characteristics analysis and experimental results.

  • PDF

퍼지논리를 이용한 직류전동기용 가변구조 위치제어시스템 (A New Variable-Structure Position Control for DC Motor Using Fuzzy Logic)

  • 이상래;이광원
    • 대한전기학회논문지
    • /
    • 제41권6호
    • /
    • pp.625-632
    • /
    • 1992
  • This paper presents a new dc-motor position control approached by Variable Structure System. In order to eliminate a steady-state position error, we propose a switching function composed of position error, velocity, and current ripple. The switching function has an advantage compared to other ones. To determine the control signal voltage, we use a fuzzy logic method. The simulation results show expected performances.

  • PDF

스위칭 손실 저감을 위한 기준전류 기울기를 이용한 단상 히스테리시스 전류 제어에 관한 연구 (A Study of Single Phase Hysteresis Current Control Using Reference Current Slope for Reducing Switching Loss)

  • 홍선기
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.150-155
    • /
    • 2009
  • 히스테리시스 전류 제어방식은 원리와 구조가 간단하여 널리 사용되었으나, 전류 오차 허용 밴드폭이 너무 작거나, 전원 전압이 상대적으로 너무 큰 경우 등에는 스위칭 주파수가 급격히 증가하여 많은 열을 발생할 수 있는 등의 단점이 있었다. 이에 본 연구에서는 단상 전류제어에서 0 모드를 추가하고, 기준 전류의 기울기를 비교하여 히스테리시스 전류 제어를 수행함으로써 대폭적인 스위칭 주파수 감소와 안정적인 전류제어가 가능하게 하였다. 또한 이를 컴퓨터 시뮬레이션을 통해 그 타당성을 확인하였다.