• Title/Summary/Keyword: Mode Attenuation

Search Result 156, Processing Time 0.028 seconds

Loss Measurements of Installed Single-Mode Optical Fibers (포설된 단일모드 광섬유의 손실 특성 측정)

  • 전영윤;박재동;이만섭;양권식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.12
    • /
    • pp.1266-1273
    • /
    • 1991
  • Attenuation losses and repeater spans of single-mode optical fibers installed in the long hual optical transmission line were measured and analyzed. The average loss including splicing points was appeared to be 0.55 0.05dB/km and 0.59 0.01dB/km at 1300nm and 1550nm, respectively, and showed lager value at 1550nm window, The cause of loss increase at 1550nm range from the OTDR measurement was due to the inappropriate treatment of extra length of fiber at the splicing points. And average repeater span of domestic long haul line was 24 7km and 90% of total sampled repeater spans was within 31 km.

  • PDF

Adaptive Sliding Mode Control Synthesis of Maritime Autonomous Surface Ship

  • Lee, Sang-Do;Xu, Xiao;Kim, Hwan-Seong;You, Sam-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.306-312
    • /
    • 2019
  • This paper investigates to design a controller for maritime autonomous surface ship (MASS) by means of adaptive super-twisting algorithm (ASTA). A input-out feedback linearization method is considered for multi-input multi-output (MIMO) system. Sliding Mode Controller (SMC) is suitable for MASS subject to ocean environments due to its robustness against parameter uncertainties and disturbances. However, conventional SMC has inherent disadvantages so-called, chattering phenomenon, which resulted from the high frequency of switching terms. Chattering may cause harmful failure of actuators such as propeller and rudder of ships. The main contribution of this work is to address an appropriate controller for MASS, simultaneously controls surge and yaw motion in severe step inputs. Proposed control mechanism well provides convergence bewildered by external disturbances in the middle of steady-state responses as well as chattering attenuation. Also, the adaptive algorithm is contributed to reducing non-overestimated value of control gains. Control inputs of surge and yaw motion are displayed by smoother curves without excessive control activities of actuators. Finally, no overshoot can be seen in transient responses.

Residual bearing capacity of steel-concrete composite beams under fatigue loading

  • Wang, Bing;Liu, Xiaoling;Zhuge, Ping
    • Structural Engineering and Mechanics
    • /
    • v.77 no.4
    • /
    • pp.559-569
    • /
    • 2021
  • This study was conducted to investigate the residual bearing capacity of steel-concrete composite beams under high-cycle fatigue loading through experiments and theoretical analysis. Six test beams with stud connectors were designed and fabricated for static, complete fatigue, and partial fatigue tests. The failure modes and the degradation of several mechanical performance indicators of the composite beams under high-cycle fatigue loading were analyzed. A calculation method for the residual bearing capacity of the composite beams after certain quantities of cyclic loading cycles was established by introducing nonlinear fatigue damage models for concrete, steel beam, and shear connectors beginning with the material residual strength attenuation process. The results show that the failure mode of the composite beams under the given fatigue load appears to be primarily affected by the number of cycles. As the number of fatigue loadings increases, the failure mode transforms from mid-span concrete crushing to stud cutting. The bearing capacity of a 3.0-m span composite beam after two million fatigue cycles is degraded by 30.7% due to premature failure of the stud. The calculated values of the residual bearing capacity method of the composite beam established in this paper agree well with the test values, which indicates that the model is feasibly applicable.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

A Study on Design of Robust $H_\infty$-QFT PSS Using Genetic Algorithm (유전 알고리즘을 이용한 강인한 $H_\infty$-QFT PSS 설계에 관한 연구)

  • 정형환;이정필;박희철;왕용필
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.371-380
    • /
    • 2003
  • In this paper, a new design method of H$H_\infty$-Qn PSS using genetic algorithm(GA) is proposed to efficiently damp low frequency oscillations despite the uncertainties and various disturbances of power systems. The selection method of evaluation function is proposed for selecting the robust PSS parameters. All QFT boundaries are satisfied automatically and H$H_\infty$-norm is minimized simultaneously without trial and error procedure. The eigenvalues and the damping ratio of dominant oscillation mode are investigated to evaluate performance of designed controller for one machine infinite bus system. A disturbance attenuation performance is investigated through singular value bode diagram of the system. Dynamic characteristics are considered to verify robustness of the proposed PSS by means of nonlinear simulations under various disturbances for various operating conditions. The results show that the proposed PSS is more robust than conventional PSS.

A Study on The Vibration Attenuation of a Driver Seat Using an MR fluid Damper

  • Park, Chan-Ho;Ahn, Byeong-Il;Jeon, Do-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.111.6-111
    • /
    • 2001
  • A seat suspension system with a controlled MR(Magneto Rheological) fluid damper is introduced to improve the ride quality and prevent the health risk of a driver compared to conventional seats. The system locates between a seat cushion and base, and is composed of a spring, MR fluid damper and controller. The MR fluid damper designed in valve mode is capable of producing a wide range of damping force according to applied currents. In experiments, a person was sitting on the controlled seat excited by a hydraulic system. The skyhook control, continuous skyhook control and relative displacement control were applied and the continuous skyhook control improved the vibration suppression by 36.6%.

  • PDF

Novel Long-period Fiber Grating devices for Monitoring the Deformation of Ship Hull (선체의 변형을 감지하기 위한 새로운 형태의 장주기 광섬유 격자 소자)

  • Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.761-767
    • /
    • 2007
  • We have developed novel optical-fiber sensors based on strain-induced long-period fiber gratings for monitoring the deformation of a hull. They have no external pressure for sustaining the mechanical formed gratings. The pressure, which provides a force to form the periodic grating along the single mode fiber, was realized by the bonding strength of a photopolymer. To reduce the polarization dependency of the sensors caused by the asymmetry structure of gratings, a Faraday Rotator Mirror (FRM) was utilized in this experiment. We have realized the polarization-insensitive function of the proposed sensors. The change of an external strain are measured by an optical spectrum analyzer. When the external stain increases. the attenuation at the resonant wavelength decreases and the loss peak was slightly shifted to the shorter wavelength.

Coupled-Mode Analysis of Two Slab Waveguides Fabricated with Vanadirum Oxide and Lithium Niobate ($VO_2와 LiNbo_3$ 로 집적된 2개의 슬랩 도파로에 관한 결합모드 해석)

  • 오환술;김영권
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.510-516
    • /
    • 1987
  • An analysis and numerical computations relating to the coupling of optical modes between two neighboring waveguides are discussed. The waveguides are fabricated with Lithium Niobate as guide 1 and Vanadium Oxide as guide 2. In a wave guide system that incorporates two lossless guides, a complete transfer of power from one guide to another can occur when the waveguides are (1) identical or (2) the modes in each guide have identical phase constants. Here we discuss the coupling effects when the guides are dissimilar with respect to both geometry and losses. In thers results, we show that power transfer can occur between the two guides, one lossy and the other lossless, provided the phase matched condition is satisfied. When properly coupled, the power attenuation varies according to the amount of coupling.

  • PDF

Murine Heart Wall Imaging with Optical Coherence Tomography

  • Kim Jee-Hyun;Lee Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.42-47
    • /
    • 2006
  • M-mode imaging of the in vivo murine myocardium using optical coherence tomography (OCT) is described. Application of conventional techniques (e.g. MRI, Ultrasound imaging) for imaging the murine myocardium is problematic because the wall thickness is less than 1.5 mm (20 g mouse), and the heart rate can be as high as six hundred beats per minute. To acquire a real-time image of the murine myocardium, OCT can provide sufficient spatial resolution ($10{\mu}m$) and imaging speed (1000 A-scans/s). Strong light scattering by blood in the heart causes significant light attenuation, which makes delineation of the endocardium-chamber boundary problematic. To measure the thickness change of the myocardium during one heart beat cycle, a myocardium edge detection algorithm is developed and demonstrated.

Variable Optical Attenuator using Parallel Plate Electrostatic Actuator (평행 평판 정전형 구동기를 이용한 가변 광 감쇠기)

  • 김태엽;허재성;문성욱;신현준;이상렬
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.448-452
    • /
    • 2004
  • The micromachined variable optical attenuator(VOA) was presented in the paper. The VOA has two single mode fiber(SMF) aligned with free space and symmetric parallel plate actuator with microshutter, which can control a amount of light by driving the actuator. In the paper, analysis on driving performances of the VOA was performed and can be reduced threshold voltage through the decreasing displacement actuating range. This paper presents a VOA that is fabricated using bosch deep silicon etching process with silicon on insulator(SOD wafer. The VOA consists of driving electrode, ground electrode, actuating microshutter, and mechanical stopper. In this VOA, actuating shutter is driven by electrostatic force and the threshold voltage is close to 28V, 46V come along with the spring width of 5${\mu}{\textrm}{m}$, 7${\mu}{\textrm}{m}$ respectively. Attenuation range is measured from 2.4㏈ to 16.7㏈.