센서최적배치 기법에 의한 원통형 구조물의 진동장 예측 (Estimation of Vibration Field of a Cylindrical Structure Derived by Optimal Sensor Placement Methods)

  • 정병규;정의봉;조대승;김국현;강명환
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.381-389
    • /
    • 2014
  • This study is concerned with the estimation of vibration-field of a cylindrical structure by modal expansion method(MEM). MEM is a technique that identifies modal participation factors using some of vibration signals and natural modes of the structure: The selection of sensor locations has a big influence on predicted vibration results. Therefore, this paper deals with four optimal sensor placement( OSP) methods, EFI, EFI-DPR, EVP, AutoMAC, for the estimation of vibration field. It also finds optimal sensor locations of the cylindrical structure by each OSP method and then performs MEMs. Predicted vibration results compared with reference ones obtained by forced response analysis. The standard deviations of errors between reference and predicted results were also calculated. It is utilized to select the most suitable OSP method for estimation of vibration field of the cylindrical structure.

유한요소법을 이용한 음향차폐장치용 탄성마운트 시스템 및 받침대의 진동모드 해석 (A Vibration Mode Analysis of Resilient Mounting System and Foundation Structure of Acoustic Enclosure using Finite Element Method)

  • 정우진;배수룡;함일배
    • 소음진동
    • /
    • 제9권3호
    • /
    • pp.493-501
    • /
    • 1999
  • The vibration modes of resilient mounting system and foundation structure which support diesel engine/generator set and acoustic enclosure walls play an important role in the vibration transmission process. So, it is necessary to perform vibration mode analysis of resilient mounting system and foundation structure. For some reasons, if the vibration modal analysis of resilient mounting system and foundation structure of acoustic enclosure could be simultaneously done by finite element method, it would be very efficient approach. In this paper, vibration modal analysis method using finite element method for multi stage mounting system having n d.o.f model was proposed. Vibration analysis of single and double stage resilient mounting system was performed to verify the validity of the proposed method. Also frequency response results were compared in case of rigid foundation model and finite element foundation model which was compared with experimental modal analysis results.

  • PDF

선박 국부구조 3 축 방향 가진 실험장치 개발 (The development of the 3 axes exciter for the local structure)

  • 이찬희;김희원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.686-690
    • /
    • 2012
  • The modal test has been carried out using the exciter machine to investigate the vibration characteristics of the hull and super structure of the ship. The conventional exciter acts only one(1) direction and the exciter should be reinstalled for different direction test, which consumes additional expense. The 3 axes exciter has been designed of which force acts three directions without reinstallation for efficient modal test of the ship. It consists of rotatable base frame structure and the clutch mechanism for the unbalances to excite three directions. And the 3 axes exciter for the local structure has been made in advance and its performance test was carried out in the laboratory. The developed 3 axes exciter shows the ability of three-directions excitation with simple operation and modal test for the various local structure of the ship will be performed.

  • PDF

Modal identification of Canton Tower under uncertain environmental conditions

  • Ye, Xijun;Yan, Quansheng;Wang, Weifeng;Yu, Xiaolin
    • Smart Structures and Systems
    • /
    • 제10권4_5호
    • /
    • pp.353-373
    • /
    • 2012
  • The instrumented Canton Tower is a 610 m high-rise structure, which has been considered as a benchmark problem for structural health monitoring (SHM) research. In this paper, an improved automatic modal identification method is presented based on a natural excitation technique in conjunction with the eigensystem realization algorithm (NExT/ERA). In the proposed modal identification method, damping ratio, consistent mode indicator from observability matrices (CMI_O) and modal amplitude coherence (MAC) are used as criteria to distinguish the physically true modes from spurious modes. Enhanced frequency domain decomposition (EFDD), the data-driven stochastic subspace identification method (SSI-DATA) and the proposed method are respectively applied to extract the modal parameters of the Canton Tower under different environmental conditions. Results of modal parameter identification based on output-only measurements are presented and discussed. User-selected parameters used in those methods are suggested and discussed. Furthermore, the effect of environmental conditions on the dynamic characteristics of Canton tower is investigated.

궤환 모델 개선법 : 부정정 구조물에의 적용 (Feedback Model Updating: Application to Indeterminate Structure)

  • 정훈상;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.59-64
    • /
    • 2003
  • The parameter modification of the initial FEM model to match it with the experimental results needs the modal information and the modal sensitivity matrix to the parameter change. There are two cases this methodology is ill-equip to deal with; the deficiency of the necessary modal information and the ill-conditioning of the sensitivity matrix. In this research, a novel concept of the feedback exciter that uses the summation of the white noise and the signals from the measurement sensors multiplied with feedback gains as the reference signal is proposed. There are 2 advantages using this external feedback excitation. First, we can use the change of the system response such as modal data by the active energy Path from the sensor to the exciter. This change of the system response can be additional clues to the system dynamics that we want to know. Secondly, the external energy Path alternates the offset of the Parameter change to the system response. That means the modal sensitivity of the parameters becomes different from the original sensitivities by the feedback excitation. Through the feedback loop, we can change the similar modal sensitivities of some updating parameters and consequently discriminate the parameters using the closed-loop modal data. To demonstrate the discrimination performance, the parameter estimation of an indeterminate structure by use of the feedback method is introduced.

  • PDF

Shape Optimization of Rotating Cantilever Beams Considering Their Varied Modal Characteristics

  • Cho, Jung-Eun;Yoo, Hong-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.246-252
    • /
    • 2004
  • The modal characteristics of rotating structures vary with the rotating speed. The material and the geometric properties of the structures as well as the rotating speed influence the variations of their modal characteristics. Very often, the modal characteristics of rotating structures need to be specified at some rotating speeds to meet their design requirements. In this paper, rotating cantilever beam is chosen as a design target structure. Optimization problems are formulated and solved to find the optimal shapes of rotating beams with rectangular cross section.

변위응답의 측정으로부터 변형률응답의 예측 (Prediction of Strain Responses from Displacement Response Measurements)

  • 이건명;신봉인;이한희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1384-1387
    • /
    • 2001
  • Presented is a method to predict strain responses from displacement measurements on a mechanical structure. The method consists of forming a transformation matrix, which is calculated from displacement and strain modal matrices. The modal matrices can be obtained by either finite element analysis or modal testing. One disadvantage of the method is that it requires displacements on all measuring points be measured simultaneously. The strain prediction method is applied to a simple simulated system.

  • PDF

강성 및 감쇠 비대칭 구조물의 모드 특성 (Modal Characteristics of a Structure with Stiffness and Damping Eccentricit)

  • 김진구;방성혁
    • 한국전산구조공학회논문집
    • /
    • 제15권3호
    • /
    • pp.421-432
    • /
    • 2002
  • 본 연구에서는 진동제어를 목적으로 강성이 평면에서 비대칭적으로 분포된 구조물에 감쇠기를 설치할 경우 감쇠편심과 강성편심에 따른 모드특성 및 변위응답의 변화에 관하여 연구하였다 모드 특성으로는 고유진동수, 모드 감쇠비, 모드참여계수, 동적 증폭계수 등의 변화를 분석하였으며, 변위는 지진이력에 대한 약변, 강변, 무게중심 등에서의 변위를 비교하였다. 또한 이를 바탕으로 비틀림 응답을 최소화하기 위한 감쇠기의 적정 감쇠 편심 및 적정 감쇠 분배 문제에 대해 논하였으며, 단층구조물에서 유도된 적정 감쇠분배 방법을 다층구조뭍에 적용하고 그 효과를 확인하였다.

Vibration control of a time-varying modal-parameter footbridge: study of semi-active implementable strategies

  • Soria, Jose M.;Diaz, Ivan M.;Garcia-Palacios, Jaime H.
    • Smart Structures and Systems
    • /
    • 제20권5호
    • /
    • pp.525-537
    • /
    • 2017
  • This paper explores different vibration control strategies for the cancellation of human-induced vibration on a structure with time-varying modal parameters. The main motivation of this study is a lively urban stress-ribbon footbridge (Pedro $G\acute{o}mez$ Bosque, Valladolid, Spain) that, after a whole-year monitoring, several natural frequencies within the band of interest (normal paring frequency range) have been tracked. The most perceptible vibration mode of the structure at approximately 1.8 Hz changes up to 20%. In order to find a solution for this real case, this paper takes the annual modal parameter estimates (approx. 14000 estimations) of this mode and designs three control strategies: a) a tuned mass damper (TMD) tuned to the most-repeated modal properties of the aforementioned mode, b) two semi-active TMD strategies, one with an on-off control law for the TMD damping, and other with frequency and damping tuned by updating the damper force. All strategies have been carefully compared considering two structure models: a) only the aforementioned mode and b) all the other tracked modes. The results have been compared considering human-induced vibrations and have helped the authors on making a decision of the most advisable strategy to be practically implemented.

CORRECTION TECHNIQUES OF MASS-LOADING EFFECTS OF TRANSDUCERS IN MODAL TESTING

  • Guoyi Ji;Chung, Won-Jee;Lee, Choon-Man;Park, Dong-Keun
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.188-188
    • /
    • 2004
  • Modal testing and analysis is a primary tool for obtaining reliable models to represent the dynamics of structures. When a structure is tested in order to collect measured data in modal testing, we usually use attached accelerometers to pick up the response data. Change in modal parameters due to the mass of transducers in modal testing is a well-known problem. The disadvantages are the shift of measured modal frequencies and the change of modal shapes, which can cause inaccurate results in further analysis. Modal analysis methods in frequency domain are based on a set of measured frequency response functions(FRF).(omitted)

  • PDF