• 제목/요약/키워드: Mock-up system

검색결과 251건 처리시간 0.061초

교반기의 진동 해석 기술 개발 (A Development of Vibration Analysis Technique of A Mixer)

  • 박진호;이정한;김봉수;안창기;강문후;주윤식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.421-426
    • /
    • 2003
  • Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. The mixer normally consists of impeller, shaft, hub, reduction gear, and the driving motor. It is one of the key design issues to confirm that the vibration caused by the rotation of the shaft should not coincide with the natural vibration frequency of the shaft itself. The vibration characteristics of the hydrofoil type mixer, which is the most widely used in real plants are evaluated through the finite element modeling and verified by experiment using the mock-up facility. The fundamental natural frequency of the mixer's shaft is found to be around 1.8 Hz which showed in good agreement with the experiment. The higher natural frequencies to the 2nd, 3rd, and 4th modes are also verified by the experiment. Thus the developed model is to be utilized for the structural design of the real mixer system.

  • PDF

Experimental validation of the seismic analysis methodology for free-standing spent fuel racks

  • Merino, Alberto Gonzalez;Pena, Luis Costas de la;Gonzalez, Arturo
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.884-893
    • /
    • 2019
  • Spent fuel racks are steel structures used in the storage of the spent fuel removed from the nuclear power reactor. Rack units are submerged in the depths of the spent fuel pool to keep the fuel cool. Their free-standing design isolates their bases from the pool floor reducing structural stresses in case of seismic event. However, these singular features complicate their seismic analysis which involves a transient dynamic response with geometrical nonlinearities and fluid-structure interactions. An accurate estimation of the response is essential to achieve a safe pool layout and a reliable structural design. An analysis methodology based on the hydrodynamic mass concept and implicit integration algorithms was developed ad-hoc, but some dispersion of results still remains. In order to validate the analysis methodology, vibration tests are carried out on a reduced scale mock-up of a 2-rack system. The two rack mockups are submerged in free-standing conditions inside a rigid pool tank loaded with fake fuel assemblies and subjected to accelerations on a unidirectional shaking table. This article compares the experimental data with the numerical outputs of a finite element model built in ANSYS Mechanical. The in-phase motion of both units is highlighted and the water coupling effect is detailed. Results show a good agreement validating the methodology.

한국표준형 원전 증기발생기 Stay 용접부 자동검사시스템 및 현장 검증 (Field Application of Ultrasonic Inspection System for Stay Welds at Steam Generator of KSNP)

  • 임사회;박치승;박철훈;주금종;노희충;윤광식
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.37-42
    • /
    • 2010
  • The stay cylinder weld at the steam generator of Korean Standard Nuclear Power Plants is safety class I component and is subjected to be inspected by the volumetric examination such as ultrasonic method. As accessibility of this area is limited due to the narrow space and high radiation, the existing manual inspection method involves various difficulties. Moreover operators may be exposed to internal contamination by contaminated dust during the surface buffing process to improve the inspection reliability of this area. Recently the new automatic inspection system for stay cylinder welds has been developed. The inspection system basically consists of a driving assembly, data acquisition device and signal processing units. The driving assembly is classified by 1) the scanner for inspecting and buffing the weld, 2) pillars for guiding the scanner and 3) the base frame for loading and supporting pillars. The scanner has 4 sensor modules to inspect in 4 refracted angles and 4 incident directions. These components can be inserted into the skirt of the stay cylinder through the manway hole and assembled easily by one-touch in the skirt. Data acquisition device and signal processing units developed in previous works are also newly upgraded for better processing of data analysis and evaluation. The system has been successfully demonstrated not only in the mock-up but also in the field. In this paper, newly developed inspection system for the stay cylinder weld of the steam generator is introduced and their field applications are discussed.

  • PDF

3차원 위치좌표를 이용한 대형 구조물 양중을 위한 계측 - 평가 시스템 (Monitoring-Evaluation System for Lifting Heavy Structures using 3D Location Data)

  • 이명호;천성철;오보환
    • 한국강구조학회 논문집
    • /
    • 제21권4호
    • /
    • pp.413-420
    • /
    • 2009
  • 일반적으로 대형 지붕구조나 초대형 보와 같은 대형 구조물을 양중하는 방법은 유압잭이 이용된다. 또한, 양중시 안전을 위하여 CCTV를 이용하여 각 포인트에 설치된 줄자를 모니터링하여 레벨체크를 수행하고, 상대 변위가 기설정된 한계를 벗어나면 유압잭을 정지하고 상대변위를 수동으로 조정한 후에 양중을 수행하였다. 그러나, 이러한 종래의 양중 방법은 CCTV를 육안으로 확인하여 레벨을 체크하기 때문에 정확도가 높지 않았고, 실시간 계측은 현실적으로 불가능하였다. 이러한 문제를 개선하기 위하여 자동추적형 토탈스테이션, 레이저 거리계, 데이터로거, 변형도게이지 등을 이용하여 대형 구조물 양중시 적용할 수 있는 계측-평가 시스템 구축하였다. 시스템을 구현하기 위한 프로그램 작성 후 실험실에서 시연을 통해 계측-평가 데이터의 정확성 및 활용 가능성을 평가하였으며, 안정적인 데이터 취득 및 연산을 통해 적용성이 검증되었다.

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

석탄-바이오매스 혼소에 따른 슈퍼히터 튜브 고온 부식 특성 연구 (High-Temperature Corrosion Characterization for Super-Heater Tube under Coal and Biomass Co-firing Conditions)

  • 박석균;목진성;정진무;오종현;최석천
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.79-86
    • /
    • 2018
  • Many countries have conducted extensive studies for biomass co-firing to enhance the durability of reactor on high-temperature corrosion. However, due to the complicated mechanisms of biomass co-firing, there have been limitations in accurately determining the current state of corrosion and predicting the potential risk of corrosion of power plant. In order to solve this issue, this study introduced Lab-scale corrosion system to analyze the corrosion characteristics of the A213 T91 material under the biomass co-firing conditions. The corrosion status of the samples was characterized using SEM/EDS analysis and mass loss measurement according to various biomass co-firing conditions such as corrosion temperature, $SO_2$ concentration, and corrosion time. As a result, the corrosion severity of A213 T91 material was gradually increased with the increase of $SO_2$ concentration in the reactor. When $SO_2$ concentration was changed from 0 ppm to 500 ppm, both corrosion severity and oxide layer thickness were proportionally increased by 15% and 130%, respectively. The minimum corrosion was observed when the corrosion temperature was $450^{\circ}C$. As the temperature was increased up to $650^{\circ}C$, the faster corrosion behavior of A213 T91 was observed. A213 T91 was observed to be more severely corroded by the effect of chlorine, resulting in faster corrosion rate and thicker oxide layer. Interestingly, corrosion resistance of A213 T91 tended to gradually decrease rather than increases as the oxide layer was formed. The results of this study is expected to provide necessary research data on boiler corrosion in biomass co-firing power plants.

신제품개발용 전문가시스템에 있어서의 지식처리 기법으로서 흑판형 추론 모델의 적용 방법에 관한 연구 (A Study on the Design Expert System for Research and Development Using Blackboard Inference Model)

  • 장승호
    • 한국시뮬레이션학회논문지
    • /
    • 제22권1호
    • /
    • pp.87-95
    • /
    • 2013
  • 신제품의 연구/개발에 있어서는 시제품의 실험결과를 토대로 개량설계를 여러 번 반복하는 경우가 많으며, 이로 인하여 시제품을 만드는 횟수가 많아지게 되는 경향이 있다. 신제품의 연구/개발에 있어서 이와 같은 불필요한 시제품을 만드는 횟수를 저감시키기 위한 목적으로 주로 컴퓨터 시뮬레이션에 기반을 둔 CAD 시스템이 많이 연구 되고 있으며, 일부는 이미 실용화되어 있다. 그러나 이와 같은 종래의 CAD시스템은 시제품의 실험결과를 합리적으로 개량설계에 반영하기 위한 기능을 CAD 시스템 내부에 갖추고 있지 않다. 본 연구에서는 다수의 지식원들의 상호 협조 작업을 통하여 문제해결 능력을 향상시킬 수 있는 특징을 갖는 흑판형 추론모델을 이용하여, 신제품의 개발설계를 적절히 지원하기 위한 전문가 시스템(DESYR ver. 1)의 구축방법을 제시하였으며, 이를 통하여 시제품의 실험결과를 보다 효과적으로 개량설계에 반영할 수 있도록 하였다. 또한, 신형 자기축수의 개발을 통하여 제시한 방법론의 타당성을 검증하였다.

MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법 (Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • 제28권6호
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Formaldehyde에 반응하는 애기장대 단백질의 분리 (Isolation of formaldehyde-responsive proteins in Arabidopsis)

  • 권미;박현진;서재현
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권4호
    • /
    • pp.52-60
    • /
    • 2007
  • 포르말린과 톨루엔 처리에 의한 애기장대의 표현형 변화 및 포르말린에 의한 단백질의 발현변화를 관찰하였다. 톨루엔의 휘발량이 포르말린보다 많음에도 불구하고 포르말린 처리구에서 애기장대의 표현형 변화가 더욱 현저한 것을 확인하였다. 포르말린에 의한 표현형의 변화가 미비한 6h 처리구에서도 애기장대 단백질의 발현에 많은 변화가 나타났으며 이러한 발현변화는 처리시간이 길어질수록 더욱 뚜렷하였다. 포르말린에 의하여 발현량이 변하는 단백질의 분자량을 automated gel electrophoresis system을 이용하여 예측한 후, 그 결과를 토대로 formaldehyde-responsive proteins을 분리하였다. 분리한 5개의 단백질은 전사수준에서 formaldehyde-dependent expression을 나타내었으며 formaldehyde-responsive proteins (FRP)으로 명명하였다. FRP5를 제외한 네 개의 단백질은 그 기능이 밝혀지지 않은 novel protein으로 식물의 방어기작에 관여하는 단백질과 높은 상동성을 나타내는 것을 알 수 있었다.

가압기 전열기 슬리브 및 J-Groove 용접부의 자동 초음파검사 (Automatic Ultrasonic Inspection on Heater Sleeves and J-Groove Welds of Pressurizer)

  • 류승우;장희준;김선제;이상덕;성종환
    • 한국압력기기공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.20-27
    • /
    • 2010
  • In order to prevent the corrosion of component contacted primary water designed alloy 600 material in the nuclear power plant. But the primary water stress corrosion cracking(PWSCC) of alloy 600 and weld area occurs continuously due to the residual stress. The leakage accident resulted from PWSCC in the drain nozzle of the steam generator of domestic power plants. Heater sleeves of the pressurizer are welded with alloy 600 weld material and therefore exposed to the primary water environment. PWSCC occurred in heater sleeve material and weld area of many foreign power plants. The current issue of domestic nuclear power plants are consequently concentrated to PWSCC of similar material. In order to improve the detection and the sizing of the PWSCC in the welding sleeve of the pressurizer, the automatic UT system and multi-directions probe sets have been developed. The experimental studies have been performed using the mock-up block containing artificial reflectors(ID connected EDM notch) and semi-artificial cracks made from thermal fatigue. The automatic UT System is applied in the detection and the length sizing of the ID/OD on the tube and the J-groove weld area of the artificial reflectors and results of the detection and the sizing are compared respectively. Also, the developed automatic UT system is successfully accomplished to inspect the heater sleeve and the J-groove weld area on the pressurizer for the detection of PWSCC.

  • PDF