• 제목/요약/키워드: Mock-up system

검색결과 251건 처리시간 0.037초

LED광원을 이용한 실내상시보조인공조명(PSALI)의 성능평가에 관한 기초적 연구 (A Basic Study on Performance Evaluation of Permanent Supplementary Artificial Lighting of Interior(PSALI) using a LED Light Source)

  • 이진숙;김병수;김소연;정용규
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.16-23
    • /
    • 2011
  • Since the first lighting light source was invented, lighting has turned into superior-quality lighting considering the amenity of occupants, and the characteristics of a light source has developed rapidly. So this research confirmed the lighting performance of a dimmer control system and an ON-OFF control system via the existing light source, and analyzed the basic lighting environment of Permanent Supplementary Artificial Lighting of Interiors(PSALI) through the physical comparison and evaluation of a LED lamp substituted for a fluorescent lamp used in a dimmer control system, showing that the lighting physical quantity characteristics of an ON-OFF control system and a dimmer control system are similar to each other and that they are effective in terms of energy saving. Besides, it was shown that introducing a LED light source to a dimmer control system improves lighting environments and largely reduces energy consumption.

공동주택의 윗목/아랫목 온돌 제어시스템 개발 및 평가 (Development and Evaluation of the Upper & Lower side Ondol System in Apartment Houses)

  • 조동우;유기형;유정연;정해권;김연홍;김상호;은민;양인호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.627-636
    • /
    • 2008
  • The purpose of this study is to develop the new korean district heating system for apartment houses. The upper & lower side ondol system with multi sensing control system was developed as a new korean district heating system and evaluated in 2 mock-up laboratories last winter. As a result of field measurement, when the load differences between perimeter zone and central zone are increased, the ondol system divided in the upper and lower side can be evaluated as the new ondol system with a capability for suppling proper heating energy for each zone. The user can have the freedom for changing an upper zone and a lower zone and controlling each temperature according to their needs.

  • PDF

외벽방호 스프링클러시스템 구성에 관한 연구 (Research for the Configuration of the Outside Sprinkler System)

  • 민세홍;윤정은;선주석;정상호;채창훈;김석준
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.102-112
    • /
    • 2012
  • 본 연구에서는 건축물 외장재 화재 시 수직화재에 대해 화염의 수직확산 방지 및 지연을 위한 외벽방호 스프링클러 설비 구성에 관하여 연구하였다. 본 연구에 앞서 관련 수직확산 방지용 스프링클러 헤드의 개발이 이루어졌으며, 적용된 스프링클러시스템은 NFPA13의 연소확대방지시스템에 명기된 방사압 0.05 MPa와 유량 60 l/min를 도입하여 적용하였다. 시스템 설계를 통하여 소방대상물에 적용하였으며 본 시스템은 감지시스템과 연동하여 자동과 수동으로 작동하도록 하였다. 또한 외벽방호 스프링클러 설비의 유용성 평가를 위해 실물실험을 실시하여 외벽의 냉각효과와 화재의 지연을 확인할 수 있었다.

데크플레이트와 경량성형재가 결합된 슬래브의 차음성능에 대한 실물실험 평가 (A Study on the Sound Insulation for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam)

  • 노영숙;윤성호
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.60-65
    • /
    • 2015
  • This study is to explore floor impact sound and sound insulation of reinforced concrete structure with void-deck slab system which combines polystyrene void foam and T-shaped steel deck plate. A void-deck slab system can effectively reduce the amount of concrete used and hence the mass of a reinforced concrete slab. Also void slab system has dynamically favorable for bending. Three-bay 2-story building was constructed as a mock up test specimen using void-deck slab system and floor impact sound was measured to valuate sound insulation performance. Light weight floor impact and heavy weight floor impact were investigated. Light weight floor impact pressure levels were 32dB, 28dB, and 29db at representative locations which are $1^{st}$ level in the floor impact sound insulation performance grading system. The heavy-weight floor impact pressure levels were 44dB, 45dB, and 43dB at representative locations which are $2^{nd}$ level in the floor impact sound insulation performance grading system. Therefore void-deck slab system can be used in public housing apartment building in terms of not only effectively reduced construction materials but also floor impact sound insulation.

사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구 (A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance)

  • 서영석;오민석;김회서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

스팬드럴 부분 BIPV창호 적용 및 후면마감재 구성에 따른 온도특성 분석 연구 (The Evaluation of the Temperature Characteristics at the Spendrels of Curtain wall with a-Si BIPV Window System)

  • 김동수;오명환;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.165-170
    • /
    • 2012
  • This study aims to analyze the characteristics of temperature variation of Spandrels. According to the change of SHGC of Window system, air space, insulation performance and absorption factor of inner surface at the Spandrels, It was firstly estimated by using simulation. Secondly, measured to minimize the temperature-rise of inner surface temperature and the intermediate air temperature by using Full-scale Mock-up based on the result of simulation analysis. As a result, it turns out that low SHGC window system such as BIPV system had an advantage of reducing the window surface temperature, and the surface temperature of clear window system was all higher than BIPV system on simulation results. In the experiment results, it had some advantages of increasing the Spandrels volume, decreasing insulation performance and lower absorption factor.

  • PDF

TPO 시트재와 유도가열공법을 적용한 고내풍성 지붕마감 공법 (The Roofing System of High wind-Resistant Performance using Thermoplastic polyolefin and Electromagnetic Induction Technology)

  • 최희복;신윤석;최진철;이보형;강경인
    • 한국건축시공학회지
    • /
    • 제9권1호
    • /
    • pp.103-109
    • /
    • 2009
  • Strong winds according to global warming cause the increase of the frequency and the repair cost of damaged roofs. In the United States, Factory Mutual Insurance Company(FMIC) promotes the roofing design that resists heavy wind-load, as the means of strict criteria. This fact reveals that more durable roofing system will be also required in Korea. Therefore, this study aims at developing such a system with high wind-resistance performance using Thermoplastic polyolefin(TPO) and Electromagnetic induction technology(EIT) than the previous systems. The system presented in this study consists of 4 main devices as follow; 1) a disc to fix sheets for TPO & EIT method, which can conduct structural design according to site condition, such as region, building height, and wind load. 2) a nail to have about 30% stronger lifting-up capacity than that of the previous nail. 3) a disc to fix sheets, which has triangle protuberance not to damage sheets in the repeatable wind load, and 4) a electromagnetic induction device to combine a disc and a sheet by heating uniformly and quickly adhesive agent on the disc. The results of mock-up test illustrate that the system provides wind-resistant performance to achieve satisfactorily the structural design criteria of FMIC. In addition, the system is faster, chipper, and easier than the existing system, and is expected that this roofing system can be applied to the rehabilitations of an existing as well as a new building.

Performance Analysis Model for Flap Actuation System using MATLAB/Simulink

  • Cho, Hyunjun;Joo, Choonshik;Kim, Kilyeong;Park, Sangjoon
    • International Journal of Aerospace System Engineering
    • /
    • 제4권1호
    • /
    • pp.13-21
    • /
    • 2017
  • In this paper, we present some results on performance analysis for flap actuation system of aircraft. For this, by utilizing MATLAB/Simulink solution, which is widely used physical model-based design tool, we particularly construct the architecture of the analysis model consisting of the main three phases: 1)commanding and outer-controlling the flap angle through flight control computer; 2)generating hydraulic/mechanical power through control module and power drive unit; 3)transmitting torque and actuating the flap through torque tube and rotary geared actuators. For mimicking the motion of the actual flap, we apply each mechanical component, which is already being used in actual aircraft, to our performance analysis model so that it guarantees the congruency of the simulation results. That is, we reflect the actual specifications of flap hardware and software as parameters of the model. Finally, simulation results are presented to illustrate the model.

노후 공동주택의 위생설비 리모델링 계획방안에 관한 연구 (A Study on the Sanitary Piping System Plan When an Aged Public Housing is Remodeled)

  • 한수곤;이상엽;이승연;홍민호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.569-574
    • /
    • 2008
  • Recently, the domestic remodeling market is increased in scale. This study is to develop the sanitary piping system which improves quality of life and facility performance when the aged public housing is remodeled. Above all, we found out three standard floor plans in bathrooms of the public housing. And then, the plan and section types of the sanitary piping system were developed for the on-floor piping, a construction cost of each section types was estimated to review the economical fact. Also, the field mock-up test was performed in the type of the pipe shaft with on-floor pit. In result, the developed sanitary piping system was available for the remodeling public housing without a great facility cost. Additionally, the sanitary pipe was replaced easily through the shaft and on-floor fit. And a noise was reduced to a lower unit when the water flowed down.

  • PDF

상태공간 Newmark 기법을 이용한 로터-베어링 시스템의 충격응답 해석 (Shock Response Analysis of Rotor-Bearing System using the State-Space Newmark Method)

  • 이안성;김병옥;김영철;김영춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.242-247
    • /
    • 2004
  • In this study was proposed a transient response analysis technique of a rotor system, applying the generalized FE modeling method of a rotor-bearing system considering a base-transferred shock force and together the state-space Newmark method of direct time integration scheme based on the average velocity concept. Experiments were performed to a test rig of a mock-up rotor-bearing system with series of half-sine shock waves imposed by an electromagnetic shaker, and quantitative error analyses between analytical and experimental results were carried out. The transient reponses of the rotor were sensitive to duration times and shape-qualities of the shock waves, and overally the analytical results agreed quite well with the experimental ones. Particularly, in cases that the frequencies, $1/(2{\times}duration\;time)$, of the shock waves were close to the critical speed of the rotor-bearing system, resonances occurred and the transient responses of the rotor were amplified.

  • PDF