Basic Design of 40ft Class Pleasure Boat based on Digital Mock-up (디지털 목업 모델 기반 40ft 급 알루미늄 레저보트 설계)

  • Oh, Dae-Kyun;Lee, Kyung-Woo;Lee, Chang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.3
    • /
    • pp.283-289
    • /
    • 2011
  • As leisure boats become large-scaled and high value-added, their design requirements gradually get more complicated and accordingly their manufacturing processes get more complicated than those of existing ones. Leisure boat builders overseas make efforts to overcome this circumstance by establishing a 3-D model-based design system which is based on the concept of PLM. On the other hand, Korean shipbuilders still remain in the development process of traditional leisure boats which are mainly based on 2-D drawings. There have been some efforts made to have the 3-D model-based design system; however, they belong to a very early stage. This study carried out initial research to apply DMU technology to the development process of leisure boats. It established the design process based on a DMU model and proved its usefulness through a case study on the design of 40-ft class aluminum leisure boats.

A Study on the Evaluation of Power Performance according to Temperature Characteristics of Amorphous Transparent Thin-Film (비정질 박막 투과형 태양전지모듈의 온도특성에 따른 발전성능 평가 연구)

  • An, Young-Sub;Song, Jong-hwa;Lee, Sung-jin;Yoon, Jong-ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.45-48
    • /
    • 2009
  • This study evaluated the influence of temperature on the PV module surface on power output characteristics, especially for an amorphous transparent thin-film PV module which was applied to a full-scale mock-up model as building integrated photovoltaic system. The tested mock-up consisted of various slopes of PV module, facing to the south. The annual average temperature of the module installed with the slope of $30^{\circ}$ revealed $43.1^{\circ}C$, resulting in $7^{\circ}C$ higher than that measured in PV modules with the slope of $0^{\circ}$and $90^{\circ}$ did. This $30^{\circ}$ inclined PV module also showed the highest power output of 28.5W (measured at 2 PM) than other two modules having the power output of 20.4W and 14.9W in the same time for $0^{\circ}$ and $90^{\circ}$ in the slope, respectively. In case of the $30^{\circ}$ inclined PV module, it exhibited very uniform distribution of power output generation even under the higher temperature on the module surface. Consequently, the surface temperature of the PV module analyzed in this study resulted in 0.22% reduction in power output in every $1^{\circ}C$ increase of the module surface temperature.

  • PDF

Applicability Evaluation of Precast Deck to the Maglev Guideway System : Mock-Up Construction Test (프리캐스트 바닥판의 자기부상열차 가이드웨이 시스템 적용성 평가 : 모의 시공 실험)

  • Jin, Byeong-Moo;Kim, In-Gyu;Kim, Young-Jin;Oh, Hyung-Chul;Ma, Hyang-Wook;Lee, Yung-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.57-60
    • /
    • 2008
  • Maglev is a system that a train runs levitated above a rail. Therefore it is very important to maintain a constant levitation gap for achieving serviceability and ride comfort. This study is a cooperation research subject of the 3-1 subject, performance improvement of maglev track structures, of the Center for Urban Maglev Program in Korea, started in 2006. The aim of this study is development of rapid constructions of bridge superstructure for maglev. At present, precast deck is widely used because of its superiority to cast-in-place concrete on quality and the term of works. The research group suggested basic systems of maglev guideway with PSC-U type and trapezoidal open steel box type girder, and precast deck, cooperating with Korea Railroad Research Institute, the managing institute of the 3-1 subject. In this study, a mock-up consisted of girders, decks and rail was fabricated and test was performed for constructability, serviceability and maintenance evaluation of PSC U-type girder, precast deck, and new guide rail system.

  • PDF

RPV 상하부에서 발생되는 금속파편의 충격위치 평가

  • 최재원;이일근;송영중;구인수;박희윤
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.166-171
    • /
    • 1997
  • LPMS(Loose Part Monitoring System)는 원자로 및 냉각재계통내에서 발생하는 금속파편의 검출 및 분석을 위하여 사용되는 진단 장비이다. 본 논문에서는 RPV(Reactor Pressure Vessel)의 상부헤드(closure head)와 하부헤드(lower head)에서의 금속파편의 충격위치를 평가하는 LPMS를 위한 새로운 기법을 제안하고, Mock-up에서의 실험을 통하여 그 효용성을 검증하였다. 즉, 수정된 원교차법을 제안하고, 이를 반구로 모델링된 RPV의 상ㆍ하부헤드에 존재하는 금속파편의 위치평가에 적용하므로써 정확한 충격위치를 찾을 수 있음을 보였다. 이들 결과는 충격물질의 질량이나 에너지를 계산하는데 정확한 정보를 제공해 줄 수가 있다.

  • PDF

The Status of Concurrent Engineering Systems in Foreign Automotive Companies (해외 자동차 업체의 CAD/CAM/CAE/PDM 통합 Engineering System)

  • 이민혁
    • CDE review
    • /
    • v.4 no.2
    • /
    • pp.36-41
    • /
    • 1998
  • To survive in the intensive world wide automotive market, more and more automotive companies are investing their resources into concurrent engineering systems (CE) based on the combined CAD/CAM/CAE/ PDM technology. The main objectives of CE in automotive companies are the quality improvement of products and the reduction of cost and time to market. Remarkable effects are appearing from some of these companies. As shown in this paper, these successful automotive companies have been focusing on establishing the new process and methodology in applying CE into their car development process.

  • PDF

Ultra-wide bandwidth versus narrow bandwidth PD detection techniques for UHF partial discharge monitoring system (초광대역과 단일주파수(협대역) UHF 부분방전 검출기법 비교)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1655-1657
    • /
    • 2002
  • Ultra-wide bandwidth (UWB), narrow bandwidth (single frequency), and a combination of both technologies have been studied for the ultra-high frequency (UHF) partial discharge (PD) monitoring system as a detection scheme. We have experimentally compared those detection methods using a mock-up of 362 kV class single phase gas-insulated switchgear (GIS) and a stable PD source. A rolling-ball type PD cell that produces PDs of about 10 pC, is placed at one end of the GIS. An internal UHF PD sensor was attached several meters away from the PD source. The PD spectrum was measured up to 3 GHz. A useable bandwidth of more than 1 GHz was used to measure UWB signals from the PD. To simulate the narrow bandwidth scheme a bandwidth of 100 kHz centered at several different frequencies was used.

  • PDF

Geometric Kernel Design of the Web-Viewer for the PDM Based Assembly DMU (PDM기반 조립체 DMU를 위한 웹뷰어 형상커널의 설계)

  • Song, In-Ho;Chung, Sung-Chong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.260-268
    • /
    • 2007
  • Demand for the use of 3D CAD DMU systems over the Internet environment has been increased. However, transmission of commercial 3D kernels has delayed the communication effectiveness due to the kernel size. Light weight CAD geometric kernel design methodology is required for rapid transmission in the distributed environment. In this paper, an assembly data structure suitable for the top-down and bottom-up assembly models has been constructed. Part features are stored without a hierarchy so that they are created and saved in no particular order. In particular, this paper proposes a new assembly representation model, called multi-level assembly representation (MAR), for the PDM based assembly DMU system. Since the geometric kernel retains assembly hierarchy and topological information, it is applied to the web-viewer for the PDM based DMU system. Effectiveness of the proposed geometric kernel is confirmed through various case studies.

The Study on The Ventilated Flow in The Railway Tunnel Mock-Up for Tunnel Fire-Driven Flow Experiment (철도터널 화재유동 실험을 위한 모형 터널에서의 환기 유동 형태에 관한 연구)

  • Jang, Yong-Jun;Kim, Seung-Tae;Kim, Dong-Hyeon;Park, Won-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1781-1788
    • /
    • 2008
  • This report is the result of a basic experiment done on a mock-up tunnel, of what happens to the ventilated flow and fire driven flow inside a railway tunnel as the current inside the tunnel changes when an anti-smoke or a radio frequency invert control is installed. The duct used in this experiment is 10m in length, 0.5m in height and 0.25m in width and made of acrylic. An anti-smoke system with a motor that can produce current of 10m/sec maximum in order to create ventilated flow, has been installed. A honeycomb has been installed at the entrance of the duct to create a current flow that exists in tunnels. In order to create a ventilated flow, a current of 4m/s, 6m/s and 8m/s were generated using the anti-smoke system, as the study of current developed. A Hot-wire(TSI) and Pressure sensor(ENDEVCO) was installed in the duct, 1m apart, as the measurement of current and pressure went on. The current and pressure were automatically measured through the Lap View program and PC; the current flow in the mock-up tunnel generated by the honeycomb has been analyzed the pressure distribution and pressure drop has been analyzed.

  • PDF