• Title/Summary/Keyword: Mock-up

Search Result 802, Processing Time 0.032 seconds

A Study on Field Application of the Mass Concrete using Hydration Temperature-Reducing Binder - Focused on the Mock-up Test- (수화 온도 저감형 결합재를 이용한 매스콘크리트 현장적용에 관한 연구 -현장 Mock-up Test를 중심으로-)

  • Seo, Il;Kwon, Hae-Won;Park, Hee-Gon;Kim, Yoo-Jin;Kim, Woo-Jae;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.371-372
    • /
    • 2010
  • This study was a result of mock-up test for the field application which was compared between low heat cement and temperature-reducing binder with the way of temperature crack reduction. The result of mock-up test was shown that the heat of hydration from the low heat cement and the temperature-reducing binder indicated 44 and $54^{\circ}C$ respectively.

  • PDF

Development of a Digital Mock-up for Conceptual Design of a Submarine (잠수함 개념 설계를 위한 디지털 목업 개발)

  • Kim, Tae-Hwan;Chun, Sang-Hoo;Sheen, Dong-Mok
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.152-157
    • /
    • 2009
  • In designing and manufacturing a submarine, an expensive real mock up is usually built as a reference because of the spatial constraints of a submarine. This paper presents an integrated and automated design process for a submarine that uses a digital mock up. Various equipment libraries are built for feature based design. Using the developed digital mock up, this paper shows various ways to verify the design, including a space analysis to check for any interference between pieces of equipment and the hull and an ergonomic analysis using lifelike dummies to examine the work space and operability. As a part of the integrated design system, a design automation system was also developed to generate surface point data for the outer hull, pressure hull, casing, and sail. The whole process was applied to the design of a submarine for verification.

Sound Insulation Measurement and Evaluation for Cabin Unit Mock Up in Vessel Satisfying NORSOK Standard (NORSOK 적용 선박의 Cabin Unit Mock Up 차음성능 계측평가)

  • Park, Jin-Hyung;Park, Hyung-Sik;Park, No-Jun;Kwun, Hyuk;Suh, Yong-Suk;Seo, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.18-19
    • /
    • 2014
  • NORWAY 해역에서 시추 및 생산 작업을 위한 시추선 및 생산 설비의 경우, 엄격한 기준인 NORSOK 기준을 만족해야 한다. NORSOK 기준은 선원들의 안전과 안락성을 위한 Working Environment 만족을 요구하고 있다. 특히 선원들의 거주구역에 안락성은 더욱 중요시되고 소음의 기준을 제시하고 만족을 요구한다. Cabin Unit 이 적용되는 선박의 경우 실선과 동일 조건의 Mock Up 을 제작하여 차음성능 계측 및 평가를 실시한다. 본 논문에서는 NORSOK 이 적용되는 선박의 Cabin Unit 의 Mock Up 차음성능 만족 사례를 소개하고자 한다.

  • PDF

Mock-up Test for Nuclear Power Plant Rebar Modulation Applying Febrication (선조립공법을 활용한 원전구조물 철근모듈화 Mock-up 실험연구)

  • Lim, Sang-Jun;Lee, Byung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.13-14
    • /
    • 2015
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. After reviewing the rebar drawing of the NPP structures and performing the mock-up test, the rebar modulation method in the various area of the NPP Structure has been established.

  • PDF

Implementation of Concurrent Engineering for Large Assembly Design: Part(II) -Developmen of a Digital Mock-Up System for Reducin Design Changes- (부품수가 많은 조립체 설계를 위한 동시공학의 구현: Part (II) -설계 변경을 줄이기 위한 Digital Mocj-Up 시스템의 개발-)

  • 정융호
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.2
    • /
    • pp.103-110
    • /
    • 1997
  • In the development of large complex assembly, most design changes are from the following reasons.: 1) insufficient consideration of assembling sequence of downstream process. 2) interference and fit-up of related parts. 3) initial design changes which are not completely resolved. In order to reduce the first reason of above, the assembly-centric modeling methodology was proposed in the part (1) of the thesis. In this part (2), a Digital Mock-Up system, which is a tool to build a virtual mock-up in design stage, has been developed in order to prevent the other two reasons. The system can build a virtual assembly in various ways as followings.: 1) assembling parts which are located in user defined envelope. 2) assembling parts with the specified disciplines. 3) assembling parts that are selected in the part list. It can also make an assembly by the combination of above methods. In addition to that, it has the functions to read/write the virtual assembly and to explode parts of the assembly in desired direction. With the virtual assembly, engineers can design interference free parts without making physical mock-up. The system has been implemented with Oracle database management system in CATIA environment.

  • PDF

High Heat Flux Test of Cu/SS Mock-up for ITER First Wall (ITER 일차벽의 Cu/SS Mock-up에 대한 고열부하 시험)

  • Lee, D.W.;Bae, Y.D.;Hong, B.G.;Lee, J.H.;Park, J.Y.;Jeong, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.325-330
    • /
    • 2006
  • In order to verify the integrity of the first wall (FW) of the International Thermonuclear Experimental Reactor (ITER), the fabricated Cu/SS mock-up is tested in the JAEA Electron Beam Irradiation Test Stand (JEBIS). To fabricate the Cu/SS mock-up, CuCrZr and 316L authentic stainless steel (SS316L) are used for Cu alloy and steel, respectively The hot isostatic pressing (HIP) is used as a manufacturing method with a $1050^{\circ}C$ and 150 MPa. The high heat flux (HHF) test is performed using an electron beam with a heat flux of $5MW/m^2$ and a cycle of 15-sec on time and 30-sec off time. The temperature measurement in the HHF test shows good agreement with the results obtained from ANSYS code analysis, which is used for determining the HHF test conditions.

A Study on the Problem Analysis and Quality Improvement in Fabricating Free-Form Buildings Facade Panels through Mock-up Panels Production (Mock-up 부재제작을 통한 비정형 건축 외장부재의 제작 문제점 분석 및 개선방안에 관한 연구)

  • Kwen, Soon-Ho;Shim, Hyoun-Woo;Ock, Jong-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.3
    • /
    • pp.11-21
    • /
    • 2011
  • The most critical issue in free-form buildings is how to construct the free-formed exterior facade panels. Their geometric complexity delivers many cons and problems in fabricating and constructing their shapes. To construct a free-form building, first of all, its skin has to be chopped into small pieces, which is called panelization. After panelization, the panels go through an optimization process to construct them economically. The panel's geometries are modified or regenerated through this optimization process. In this study, the panel optimization process of free-form buildings are performed through a case study. The panel shapes of the case study are modeled with Digital Project. To test the constructability of the various panels, 8 mock-up panels are made and laser scanning technology is applied to measure the preciseness of the panels manufactured in comparison with their original design.

Design Planning and Evaluation using Mock-up for the Short-term Temporary Housing (단기 임시주거를 위한 설계계획 및 목업을 통한 성능평가)

  • Lee, Won-Hak;Lee, Byung-Yun;Cho, Young-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.609-616
    • /
    • 2019
  • This paper proposes a design plan of short-term temporary housing for the victims by disaster. Also construction workability and residential environment evaluated by mock-up. In particular, in the event of a disaster, victims have lived the auditorium or gymnasium of the nearby school which is an emergency shelter. However, there was a problem of livability. Therefore, it is the purpose of study to provide temporary housing that resides within 30 days. For this purpose, a composite panel with light weight and insulation select to produce mock-up. The mock-up complete in about an hour. This is because it is made only of the composite panels. The composite panels confirm to be easy to load and construct. And mock-up evaluates insulation and waterproofing performance in the laboratory. As a result, Mock-up has insulation and waterproofing performance. This suggests an alternative to short -term temporary housing.

Safety Evaluation of Void Plywood Slab System with form Work Panel (거푸집 패널이 부착된 중공슬래브의 안전성 평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;Park, Tae-Won;Kang, Hyun-Wook;Park, Hyun-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.185-192
    • /
    • 2021
  • In this study, Full-scale hollow slab Mock-up with VPS(Void Plywood Slab System) was produced. Through Mock-up, the safety of the flat plate hollow slab against short-term sagging and long-term sagging is to be evaluated. The hollow rate of the mock-up specimen to which the hollow core slab was applied was designed to be 24%. When loading through concrete blocks, the most central part of the slab was deflection 8.88mm when loading. However, it shows a safe value compared to the reference value (ln/240=17.93mm) for short-term deflection. As a result of 3 months of measurement of the mock-up experiment, the deflection at the center of the slab increased by 6.792mm from the initial deflection. In addition, it was found that the reference value by the load used suggested by KBC2016 was satisfied.