• 제목/요약/키워드: Mock Up

Search Result 808, Processing Time 0.025 seconds

A study on the Improvement of Electromyography of Agricultural Work Chairs for the Prevention of Musculoskeletal Disorders

  • June Hwan Kim;Eun Suk Lee;Won Sik Choi
    • International journal of advanced smart convergence
    • /
    • v.12 no.2
    • /
    • pp.76-83
    • /
    • 2023
  • Squatting of agricultural work can cause musculoskeletal disorders due to excessive pressure and rotational force on the knee joint In order to improve the assistive chair used in squatting agricultural work so that it can be used in a narrow groove, it is intended to improve the musculoskeletal harm of squatting work by attaching a spring on the assistive chair. Therefore, in the presenty study, 3D drawing was done using ProEngineer (3D), and a mock-up was produced and tested. Using pro-Engineer, it was judged that it was rare for plastic to be broken by a spring, so the analysis was conducted with a focus on springs. It was found that the structure that can absorb the shock according to the rigidity of the tape spring and balance the body is that the power to withstand the load of the weight is distributed as a whole when five springs are used. Electromyography was measured using ME600 (Mega Electronics, Finland) Measuring equipment attached to the waist, thighs, calves, and shins. EMG values were measured and compared with the prototype in two ways, when the worker did not wear the product and when he wore an existing product on the market. As a result of the experiment when using the prototype, the maximum EMG value for each part is considered to be helpful in preventing musculoskeletal diseases as the amount of muscle used is reduced in the waist, thighs, calves, and shins.

Radiological safety analysis of a newly designed spent resin mixture treatment facility during normal and abnormal operational scenarios for the safety of radiation workers

  • Jaehoon Byun;Seungbin Yoon;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1935-1945
    • /
    • 2023
  • The radiological safety of workers in a newly developed microwave-based spent resin treatment facility was assessed based on work location and operational scenarios. The results show that the remote-operation room worker was exposed to maximum annual dose of 3.19E+00 mSv, which is 15.9% of the dose limit, thereby confirming radiological safety. Inside the pathway, annual doses in the range of 7.87E-02-2.07E-01 mSv were measured initially at the mock-up tank and later at the point between the spent resin separation and treatment parts. The dose of emergency maintenance workers was below the dose limit (4.08E-03-4.99E+00 mSv); however, before treatment (separation and microwave), the dose of maintenance and repair workers exceeded the dose limit. The doses of the effluent removal workers at the zeolite and activated carbon storage tank and spent resin storage tank were the lowest at 2.79E-01-2.87E-01 mSv and 9.27E-01 mSv in "1 h" and "4-5 h of operation", respectively. The immediately lower and upper layers of the facility room exhibited the highest annual doses of 1.84E+00 and 3.22E+00 mSv, respectively. Through this study, a scenario that can minimize the dose considering the movement of spent resin through the facility can be developed.

A study on the implementation of door control unit for railway trains operable at low and high platforms

  • Young-Seok Cho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.1-9
    • /
    • 2023
  • Currently, as the demand for stops in the urban increases resulting from an increase in the supply of express trains, the development of trains capable of operating both high-floor platforms in the urban and low-floor platforms in the suburbs is required. In this paper, we studied the design and fabrication of a controller for train doors that consists of low and high steps as a plug-in type door mechanism and thus can be used on low and high platforms. This DCU H/W was designed and implemented using 32 bit MCU to control 4 motors, 33 digital inputs and 16 digital outputs. In addition, based on the software life cycle of EN50128, 2 items of operation requirements and 12 items of control requirements were derived, and then they were designed and implemented as operation SW. The implemented SW was tested for each requirement. As a result, we performed tests on 13 items that could be tested in the mock-up out of 14 total requirement items and showed that the requirements were satisfied.

Measurement of Terminal Velocity for Scatter Prevention of Powder in the Voloxidizer for Oxidation of UO$_{2}$ Pellet (UO$_{2}$ 펠릿 산화로의 분말 비산 방지를 위한 최종속도 측정)

  • Kim Young-Hwan;Yoon Ji-Sup;Jung Jae-Hoo;Jin Jae-Hyun;Hong Dong-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.77-84
    • /
    • 2005
  • A voloxidizer for a hot cell demonstration, that handles spent fuels of a high radiation level in a limited space should be small and spent fuel powders should not be dispersed out of the equipment involved. In this study a density rate equation as well as the Stokes'equation has been proposed in order to obtain the theoretical terminal velocity of powders. The terminal velocity of U$_{3}$O$_{8}$ has been predicted by using the terminal velocity of SiO$_{2}$, and then determination has been the optimum air flow rate which is able to prevent powders from scattering. An equation which has shown a relationship between theoretical terminal velocities of U$_{3}$O$_{8}$ and SiO$_{2}$ has been derived with the help of the Stokes'equation, and then an experimental verification made for the theoretical Stokes' equation of SiO$_{2}$ by means of an experimental device made of acryl. The theoretical terminal velocity based on the proposed density rate equation has been verified by detecting U$_{3}$O$_{8}$ powders in a filter installed in the mock-up voloxidizer. As the results, the optimum air flow rates seem to be 20 LPM by the Stokes'equation while they are 14.5 L/min by the density rate equation. At the experiments with the mock-up voloxidizer, a trace amount of U$_{3}$O$_{8}$ seems to be detectable at the air flow rate of 14.5 L/min by the density rate equation, but U$_{3}$O$_{8}$ powders of 7$\mu$m diameter seem detectable at the air flow rate of 20 L/min by the Stokes'equation. It is revealed that 14.5 L/min is the optimum air flowe rate which is capable of preventing U$_{3}$O$_{8}$ powders from scattering in the UO$_{2}$ voloxidizer and the proposed density rate equation is proper to calculate the terminal velocity of U$_{3}$O$_{8}$ powders.

  • PDF

Clinical Evaluation of Surgical Treatments for Ten Cases of Tuberculous Spondylitis (결핵성 척추염 10례의 수술적 치료에 관한 임상적 고찰)

  • Whee, Sung Mock;Eoh, Whan;Nam, Do Hyun;Lee, Jung Il;Kim, Jong Soo;Hong, Seung-Chyul;Shin, Hyung Jin;Park, Kwan;Kim, Jong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1314-1319
    • /
    • 2001
  • Objects : Because of the nonspecific nature of symptoms in tuberculous spondylitis, a delay in the diagnosis can result in progressive neurologic deficits. The authors evaluate the clinical and the radiological results of the 10 cases of surgically treated tuberculous spondylitis. Clinical materials & Methods : We retrospectively analyzed the medical records of 10 patients with tuberculous spondylitis who were treated between February 1996 and March 2000. Six patients were female, and four were male. Mean age was 43 years old, and mean follow-up period was 20.5 months. All patients were treated with 12 months of antituberculous medication postoperatively, and were followed by complete blood count, ESR, spine X-ray and MRI. Results : The lumbar spine was involved in 5 patients, the thoracic in 4, and the thoracolumbar in one. The infected vertebral bodies were 2.8 in average. The associated lesions were pulmonary tuberculosis in 3 cases, and renal tuberculosis in one. Five patients were treated by anterior debridement and fusion with bone graft using anterior instrumentation, 2 with anterior debridement and fusion with bone graft(Hong Kong procedure only), 1 with Hong Kong procedure with posterior spinal instrumentation, and 2 were managed with posterior debridement and posterior spinal instrumentation. All patients improved after operation, and the average kyphotic angle decreased postoperatively. Postoperatively, one patient had a fistula at the operative site. Conclusion : The debridement and minimal level fusion of motion segment with instrument fixation is one of surgical option for tuberculous spondyltis to preserve the spine motion segment as much as possible. Spine instability and kyphosis were prevented by anterior and posterior spinal instrumentation. But, large number of cases and longer period follow-up study in future will be needed to confirm the long term results.

  • PDF

Effectiveness Assessment on the Soil Temperature of KMA as Ground Heat Source Using CFD in Pit Area (CFD를 이용한 기상청 지중온도의 피트부분 지중열원 유용성 평가에 관한 연구)

  • Min, Joon Ki;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.49-54
    • /
    • 2008
  • The experimental of temperature, humidity and velocity was taken from the underground pit which utilized the system of ground heat source quite similar to the cool-pit system. Also, through CFD analysis, one could review the effectiveness of analysis of future alternatives. Furthermore, the temperature range of mock up cool-pit system was analyzed by inputting the weather data of annual average soil temperature provided by KMA(Korea Meteorological Administration) into the fluid simulation of anticipated heat distribution. Firstly, the difference between the temperature of air exhaust of the pit or the temperature of air supply of the compressor room and the experimental data for the month of May from the CFD analysis came out to be $0.6^{\circ}C$ and $0.9^{\circ}C$ respectively with tolerance of 3.1% and 4.7%. Secondly, the difference between the temperature of air exhaust of the Pit or the temperature of air supply of the compressor room and the experimental data for the month of July from the CFD analysis came out to be $0.8^{\circ}C$ and $1.1^{\circ}C$ respectively with tolerance of 3.3% and 4.5%. Thirdly, for the month of May, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.9^{\circ}C$ and $1.8^{\circ}C$ respectively with tolerance of 10.7% and 9.8%. Fourthly, for the month of July, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.1^{\circ}C$ and $1.4^{\circ}C$ respectively with tolerance of 4.5% and 5.8%. The result of above experiments allowed us to establish CFD model set up as a verification tool that is based on experimental data collected within the Pit area. Also, one could confirm the possibility to apply weather data of soil temperature provided by KMA in order to anticipate proper value for CFD analysis.

Three Cases of Mitochondrial Disorders in the Neonatal Period (신생아기에 진단된 미토콘드리아 질환 3례)

  • Kim, Yoon-Hee;Lee, Young-Mock;Namgung, Ran;Kim, Jeong-Eun;Lee, Soon-Min;Park, Kook-In;Kim, Se-Hoon;Lee, Jin-Sung
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.254-261
    • /
    • 2010
  • Little is known about neonatal mitochondrial disease, though mitochondrial metabolic disorders may often present in the neonatal period because of the high energy requirement of neonate. In newborn period, common presentations are not specific and the disease course may be rapid and fatal. In this study, we report three cases of neonatal mitochondrial disease. The first case was strongly suspected because of sudden seizure and mental change with severe lactic acidosis, and multiorgan failure. Plasma lactate/pyruvate (L/P) ratio was increased to 55.6 with marked lactic aciduria and increased plasma alanin up to 2,237 nmol/mL. In the second patient, a peritoneal dialysis was performed for acute adrenal and renal failure, but metabolic acidosis persisted. Plasma L/P ratio was increased to 23.9, and MRC I (mitochondrial respiratory chain defect) was diagnosed through the enzymatic analysis of the muscles. The third case showed repetitive episode of lactic acidosis during the first two months of life, hypotonia, failure to thrive and feeding difficulties. We found markedly increased cerebrospinal fluid L/P ratio up to 57 though plasma L/P ratio(19.4) was borderline with increased plasma lactate. The lactate peak was prominent in brain magnetic resonance spectroscopy (MRS). MRC II was confirmed through muscle biopsy. Plasma lactate level and lactate peak of brain MRS were normalized after conservative treatment.

Flexural & Fatigue Evaluation of Link Slab for Continuous Girder-Type Precast Modular Bridges (거더형식 프리캐스트 모듈러교량 연속화 지점부에 적용되는 연결슬래브의 휨성능 및 피로성능 평가)

  • Joo, Bong-Chul;Song, Jae-Joon;Lee, Sang-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.517-528
    • /
    • 2013
  • The modular technology has been already applied in automotive industry, plant and shipbuilding industry. Recently, the modular technology was applied in bridge construction. The modular bridge is different from the existing precast bridges in terms of standardized design that the detailed design of members is omitted by using the standard modules; the design of the modular bridge is completed by only assembling the standard modules without design in member level. The girder-type precast modular bridge has been developed as a simply supported bridge. The girder-type precast modular bridge could be applied to the multi-span bridges through the continuity method. The continuity of the girder-type precast modular bridge is achieved by using the link slab which is easy to construction and appropriate to the rapid construction. The link slabs have been used as the type of reinforced concrete structure in US from the 1950's. In 2000's, the link slab using the engineered cementitious concrete (ECC link slab) has been developed. In this study, the RC type link slab which is more reproducible and economic relative to the ECC link slab was used for the continuity of the girder-type precast modular bridges, and the construction detail of RC type link slab was modified. In addition, the modified iterative design method of RC type link slab was proposed in this study. To verify the proposed design method, the flexural tests were conducted using the RC type link slab specimens. Also, the fatigue test using the mock-up specimen was conducted with cyclic loading condition up to two million cycles.

Floor Impact Noise Characteristics Depending on the Experimental Conditions Using Impact Ball (실험조건에 따른 임팩트 볼의 바닥충격음 변화 고찰)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.92-99
    • /
    • 2011
  • In Japan, bang machine has been considered to have problems about not only the impact force and frequency response which are different from the real impact sources such as children's jumping and running, but also damage in the wooden structure housing. Therefore, a new impactor for lower impact force to prevent demage in wooden structure housing was developed. The impact ball was adopted as the second standard impact source in JIS A 1418-2 and ISO 140-11. In the present study, floor impact sounds generated by impact ball with drop heights in four floors of mock-up building of Building Research Institute (BRI) similar to typical Japanese wooden structure housing were investigated and also compared to jumping sound. The results show that Impact ball sound dropped at 10 cm to 30 cm was most similar to jumping sound. And The impact sound levels at 250 and 500 Hz were more sensitive to drop height than other lower frequencies. The error that may occur from the difference of height of 10 cm up and down based on the standard drop height caused by the impact ball operated by human hands was approx. 1 dB or less only in its value of characteristic, but it must be carefully taken into Impact ball in the Korea Standard.

Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge (고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구)

  • Chung, Kyoung-Jae;Lee, Seok-Geun;Dang, Jeong-Jeung;Choi, Gil-Hwan;Hwang, Y.S.;Kim, Chul-Young;Park, Young-Jun
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The application of appropriate rehabilitation methods can improve the efficiency of clogged wells and extend their life. In this paper, we study the feasibility of well cleaning using high-voltage pulsed discharge, in which electrical energy is used to produce impulsive pressure in water, in contrast to conventional methods that employ chemical or pneumatic energy sources. This technique utilizes the compressive shock wave generated by the expansive force of hot, dense plasma that is produced during a pulsed discharge in the gap between electrodes immersed in water. Compared with conventional techniques, this method is simple, and easy to handle and control. Using a capacitive pulsed power system with an electrical energy of 200 J, an impulsive pressure of 10.7 MPa is achieved at the position 6 cm away from the discharge gap. The amplitude of the impulsive pressure was easily controlled by adjusting the charging voltage of the capacitor and was almost linearly proportional to peak discharge current. The technique achieved good results in cleaning feasibility tests with mock-up specimens similar to clogged well screens.