• Title/Summary/Keyword: Mobile healthcare device

Search Result 74, Processing Time 0.033 seconds

A Mining-based Healthcare Multi-Agent System in Ubiquitous Environments (마이닝 기반 유비쿼터스 헬스케어 멀티에이전트 시스템)

  • Kang, Eun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2354-2360
    • /
    • 2009
  • Healthcare is a field where ubiquitous computing is most widely used. We propose a mining-based healthcare multi-agent system for ubiquitous computing environments. This proposed scheme select diagnosis patterns using mining in the real-time biosignal data obtained from a patient's body. In addition, we classify them into normal, emergency and be ready for an emergency. This proposed scheme can deal with the enormous quantity of real-time sensing data and performs analysis and comparison between the data of patient's history and the real-time sensory data. We separate Association rule exploration into two data groups: one is the existing enormous quantity of medical history data. The other group is real-time sensory data which is collected from sensors measuring body temperature, blood pressure, pulse. Proposed system has advantage that can handle urgent situation in the far away area from hospital through PDA and mobile device. In addition, by monitoring condition of patient in a real time base, it shortens time and expense and supports medical service efficiently.

Design and Implementation of IEEE 11073/HL7 Translation Gateway Based on U-Healthcare Application Service for M2M (M2M을 위한 U-헬스케어 응용 서비스 기반 IEEE 11073/HL7 변환 게이트웨이 설계 및 구현)

  • Chun, Seung-Man;Nah, Jae-Wook;Park, Jong-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.275-286
    • /
    • 2011
  • As the 21st century paradigm of healthcare service changes from post-therapeutic treatment to disease prevention and management in advance, the M2M-based u-healthcare application service is increasingly important. M2M-based u-healthcare application service uses mobile handsets equipped with sensors to measure vital information, and the medical staff in remote locations can manage the health of the patient or the public in real time. In this paper, IEEE/HL7 translation gateway, utilizing the gateway based on M2M u-healthcare application service structure, which is based on international standards, has been designed and implemented. Specifically, the gateway between ISO/IEEE 11073 standards and ANSI HL7 has been developed. The former defines the protocol for the exchange of information between the agent device and the manger devices for measuring and handling biological signal, and the latter defines the application layer protocol for the exchange of various healthcare information systems. Finally, in order to demonstrate the functionality of the proposed architecture, the M2M-based U-healthcare application service based on IEEE/HL7 translation gateway, utilizing the gateway, has been developed which can measure, collect and process a variety of vital signs such as ECG or SpO2.

Design and Implementation of IoT based Urination Management System (사물인터넷 기반의 배뇨관리 시스템 설계 및 구현)

  • Lee, Hak-Jai;Lee, Kyung-Hoon;Kim, Young-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.209-218
    • /
    • 2017
  • Healthcare services can be provided through a number of independent service platforms for measurement of vital signs, diagnosis and prevention of diseases, and Information and communication technology(ICT) such as internet and mobile are converged to provide health information to users at anytime and anywhere, and it is in the center of the IoT(Internet of things). Accordingly, in this paper, we designed IoT based urination management system and evaluate the performance. A low - power Zigbee network was constructed for the configuration of the urination management system. The implemented capacitive diaper sensor was operable for the duration of 2,000 hours. We also built a database server using Raspberry Pi, a tiny embedded device, and stored the collected data to verify the data through an Android-based mobile application. The proposed urination management system can be utilized not only for the older patients, but also for the infants.

Design and Implementation of a Mobile-based Sarcopenia Prediction and Monitoring System (모바일 기반의 '근감소증' 예측 및 모니터링 시스템 설계 및 구현)

  • Kang, Hyeonmin;Park, Chaieun;Ju, Minina;Seo, Seokkyo;Jeon, Justin Y.;Kim, Jinwoo
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.3
    • /
    • pp.510-518
    • /
    • 2022
  • This paper confirmed the technical reliability of mobile-based sarcopenia prediction and monitoring system. In implementing the developed system, we designed using only sensors built into a smartphone without a separate external device. The prediction system predicts the possibility of sarcopenia without visiting a hospital by performing the SARC-F survey, the 5-time chair stand test, and the rapid tapping test. The Monitoring system tracks and analyzes the average walking speed in daily life to quickly detect the risk of sarcopenia. Through this, it is possible to rapid detection of undiagnosed risk of undiagnosed sarcopenia and initiate appropriate medical treatment. Through prediction and monitoring system, the user may predict and manage sarcopenia, and the developed system can have a positive effect on reducing medical demand and reducing medical costs. In addition, collected data is useful for the patient-doctor communication. Furthermore, the collected data can be used for learning data of artificial intelligence, contributing to medical artificial intelligence and e-health industry.

Real-time vital signs measurement system using facial image on Mobile (모바일 환경에서 안면 영상을 이용한 실시간 생체징후 측정 시스템)

  • Kim, Dae Yeol;Kim, Jin-Soo;Lee, Kwang-Kee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.11a
    • /
    • pp.94-97
    • /
    • 2020
  • 코로나 시대에 도래하며 비접촉 방식의 생체 징후에 대한 관심이 증가하고 있다. 본 연구는 비접촉식 측정 방식으로써 모바일 전면 카메라를 이용하여 심장박동, 심장 박동 변이율, 산소포화도, 호흡도, 스트레스 수치를 측정할 수 있는 효과적인 방법론을 제시하는 것이 목적이다. 모바일 전면부 카메라에서 실시간으로 안면 영상을 추출하기 위하여 Blaze Face를 이용하였으며, 안면 영상의 특징점인 눈, 코, 입, 귀의 위치를 이용하여 이마 부분의 관심 영역을 지정하였다. 관심 영역에서 색상 성분을 R, G, B로 분리하여 시간 축으로 정렬 후 fourier transform을 진행한 후 각각의 성분들을 측정하고자 하는 생체 징후에 맞게 Filter 처리함으로써 생체 징후를 측정하였다. 안면 영상을 이용한 생체 징후 측정 결과를 검증에 활용하기 위하여 실측 기기인 mCube-Healthcare device를 이용하였으며, 분석 결과 모바일에서 안면 영상을 통해 심장박동, 삼장 박동 변이율, 산소포화도, 호흡도, 스트레스 수치의 다섯 가지 생체 징후를 추출할 수 있는 가능성을 확인하였다.

  • PDF

Development of device for cat healthcare monitoring using Smartphone

  • Nam, Heung Sik;Lee, Moon Joo;Kim, Geon A
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.157-163
    • /
    • 2022
  • In this paper, we propose to develop a Bluetooth Health Device Profile (HDP)-based smartphone system to utilize it for early detection of urinary tracts diseases that occur a lot in cats. Therefore, based on Bluetooth HDP, we developed a device and mobile application system (Mycatner®) that can monitor cat activity, toilet usage, urinary disease, and health status, and evaluated its availability to monitor cat health status. The specific feature of this system is that it can measure the number of cat urination frequencies to identify abnormal conditions suspected of urinary tract diseases early, and second, it can be tested with urine test paper and shared with animal hospitals, reducing time and cost. As a result, it is evaluated that the developed device capable of wireless monitoring the urinary system health status of cats is the first in our knowledge.

Self-Organizing Middleware Platform Based on Overlay Network for Real-Time Transmission of Mobile Patients Vital Signal Stream (이동 환자 생체신호의 실시간 전달을 위한 오버레이 네트워크 기반 자율군집형 미들웨어 플랫폼)

  • Kang, Ho-Young;Jeong, Seol-Young;Ahn, Cheol-Soo;Park, Yu-Jin;Kang, Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.630-642
    • /
    • 2013
  • To transmit vital signal stream of mobile patients remotely, it requires mobility of patient and watcher, sensing function of patient's abnormal symptom and self-organizing service binding of related computing resources. In the existing relative researches, the vital signal stream is transmitted as a centralized approach which exposure the single point of failure itself and incur data traffic to central server although it is localized service. Self-organizing middleware platform based on heterogenous overlay network is a middleware platform which can transmit real-time data from sensor device(including vital signal measure devices) to Smartphone, TV, PC and external system through overlay network applied self-organizing mechanism. It can transmit and save vital signal stream from sensor device autonomically without arbitration of management server and several receiving devices can simultaneously receive and display through interaction of nodes in real-time.

Design of a Data Grid Model between TOS and HL7 FHIR Service for the Retrieval of Personalized Health Resources (개인화된 건강 자원 조회를 위한 TOS 와 HL7 FHIR 서비스간의 데이터그리드 모델 설계)

  • Jeon, Young-Jun;Im, Seok-Jin;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.139-145
    • /
    • 2016
  • On the ICT healing platform designed to issue early disease alerts, TOS connected between the provider of personal health-related data and the service provider and relayed personalized health data. In the previous study, TOS proposed how to monitor the retrieval and management of document/measurement resources by taking mobile devices into account. Recently the healthcare field, however, defined the standard items needed for communication and data exchanges with a mobile device through HL7 FHIR. This study designed a data grid model between TOS and FHIR to provide personal health resources relayed through TOS in FHIR bundle search sets. The proposed design was organized as follows: first, it stated similarities between the method of TOS resource request and that of FHIR observation request. Then, it designed an eventbus module to process a retrieval request for FHIR service based on the imdb and cluster technologies. The proposed design can be used to expand the old service terminals of ICT healing platform to mobile health devices capable of using FHIR resources.

Design of Filter to Reject Motion Artifacts of PPG Signal Using Multiwave Optical Source (다파장 광원을 이용한 광용적 맥파의 동잡음 제거 필터 설계)

  • Park, Heejung;Nam, Jaehyun;Lee, Juwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • This study is proposed the novel PPG sensor device and the signal processing method to replace the acceleration sensor that is used to reject motion artifacts contained in photoplethysmography(PPG). The proposed method is to reject motion artifacts by an adaptive filter based on the estimated motion artifact by using a blue LED light. To evaluate the performance of the proposed method experimentally, We did design a novel sensor consisted of blue/red LEDs and photo-sensor and implemented, and then rejected the motion artifacts by using an adaptive filter and the implemented sensor. In the results of the experiments, it is shown that the proposed sensor device and signal processing can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the SNR was 4.5 times of moving average filter. According to the experimental results, the proposed method can be applied to design a low-cost device.

Design of Filter to Remove Motionartifacts of Photoplethysmography Based on Indepenent Components Analysis and Filter Banks (독립성분 분석법과 필터뱅크를 기반한 PPG 신호의 동잡음제거 필터 설계)

  • Lee, Ju-won;Lee, Byeong-ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1431-1437
    • /
    • 2016
  • In mobile healthcare device, when to measure the heart rate by using the PPG signal, its performance is reduced according to the motion artifacts that is the movement of user. This is because the frequency range of motion (0.01-10 Hz) and that of PPG signals overlap. Also, the motion artifacts cannot be rectified by general filters. To solve the problem, this paper proposes a method using filter banks and independent component analysis (ICA). To evaluate the performance of the proposed method, we were artificially applied various movements and compared heart rate errors of the moving average filter and ICA. In the experimental results, heart rate error of the proposed method showed very low than moving average filter and ICA. In this way, it is possible to measure stable heart rate if the proposed method is applied to the healthcare terminal design.