• Title/Summary/Keyword: Mobile Monitoring

Search Result 921, Processing Time 0.023 seconds

High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Won-Woong;Lee, Sun-Young;Yu, Se Mi;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3727-3734
    • /
    • 2012
  • An analytical method has been developed for the rapid determination of perfluorinated compounds (PFCs) in human serum samples. The extraction and purification of PFCs from human serum were performed by the modified method of previous report. Ten PFCs were rapidly separated within 3.3 min by C18-monolithic column liquid chromatography (LC) and detected by electrospray ionization (ESI) tandem mass spectrometry (MS/MS) in negative ion mode. The runtime of PFCs on monolithic column LC was up to 4-fold faster than that on conventional column LC. The effect of triethylamine (TEA) to the mobile phase has investigated on the overall MS detection sensitivity of PFCs in ESI ionization. Quantification was performed by LC-MS/MS in multiple-ion reaction monitoring (MRM) mode, using $^{13}C$-labeled internal standards. Method validation was performed to determine recovery, linearity, precision, and limits of quantification, followed by, the analysis of a standard reference material (SRM 1957 from NIST). The overall recoveries ranged between 81.5 and 106.3% with RSDs of 3.4 to 16.2% for the entire procedure. The calibration range extended from 0.33 to 50 $ng\;mL^{-1}$, with a correlation coefficient ($R^2$) greater than 0.995 and the limits of quantification with 0.08 to 0.46 $ng\;mL^{-1}$. This approach can be used for rapid and sensitive quantitative analysis of 10 PFCs in human serum with high performance and accuracy.

Quality Monitoring of Specification of Crataegi Fructus in the Korean Pharmacopoeia and Studies HPLC Standard Chromatogram (산사(山楂)의 규격 기준 모니터링 및 HPLC 표준크로마토그램 연구)

  • Kim, Kyoung Hee;Kim, Sun Mi;Lee, Young Jong;Baek, Wan Sook
    • The Korea Journal of Herbology
    • /
    • v.32 no.1
    • /
    • pp.55-62
    • /
    • 2017
  • Objectives : Crataegi Fructus has been used as traditional medicines for more digestion action, amenorrhea due to blood stasis, and hyperlipemia. The aim of this study was to compare of Crataegi Fructus in South Korea collected during three years according to the standards in monographs of the Korean Pharmacopoeia Eleventh edition (KP 11). Methods : Crataegi Fructus was carried out identification test (Qualitative reaction, Thin layer chromatography), heavy metal test, and total ash registered at KP. Add to we tested loss on dry, contents of ethanol-soluble extracts, and HPLC profiling. Results : Identification test (TLC) was on comparing with ursolic acid standard solution in $R_f$ value, all samples showed red purple spot ($R_f$ value 0.9). Ursolic acid spot in $R_f$ value 0.35 showed by changing mobile phase condition. Heavy metals showed contents for Pb, Cd, As, and Hg range of 0.0 ~ 0.5 ppm, 0.0 ~ 0.2 ppm, 0.0 ~ 0.3 ppm, and 0.0 ~ 0.1 ppm. Loss on drying was ranged from 5.5 to 11.9 %, total ash was between the range 2.7 ~ 4.0 %. Contents of ethanol-soluble extracts was ranged from 17.8 to 44.9 %. The content of chlorogenic acid was ranged from 0.0 to 0.1 % based on the chlorogenic acid standard curve. Conclusion : We have verified the current specification standard of Crataegi Fructus and standard that is not set. We hope that it will help the standardization of Crataegi Fructus.

A Study on The Internet Connectivity in The Philippines

  • Salac, Romeo Agan;Kim, Yun Seon
    • Asia Pacific Journal of Business Review
    • /
    • v.1 no.1
    • /
    • pp.67-88
    • /
    • 2016
  • This study aims to help address concerns about the growing demand of wider bandwidth Internet connection in the Philippines. Using articles and research of international organizations and content from official websites of the Philippine government, this paper has carefully examined the slow Internet connectivity and the high cost that the end-users pay for it. This paper suggests that this inefficiency hampers the motivation of users to innovate in a way that could contribute to inclusive growth and the development of an inclusive information society. Through a comparison of the current global ICT situation with the current situation in the Philippines, this paper shows that the country's Internet infrastructure lags behind among those of contemporary developing countries in Asia, particularly in terms of Internet connectivity. In 2015, Thailand had an average Internet speed of 7.4 Mbps, Sri Lanka 7.4, and Malaysia 4.3. Meanwhile, the Philippines had a meager average Internet speed of 2.8 Mbps, placing the country at 104 among 160 countries, with developed countries in Asia such as South Korea (23.6 Mbps) and Singapore (12.9 Mbps) ranking 1 and 12, respectively. Findings show that the lack of competition in the Internet connectivity market, among other reasons, is at the root of the dilemma of slow and costly Internet connection. Assessing the accomplishments of the Republic of Korea and other broadband-leading countries has provided practical insights and recommendations that can promote competitiveness. Furthermore, related literature argues how ISP practices may affect Internet speed and cost. This study offers an approach in improving Internet connectivity in the Philippines by bridging the gap between the Internet infrastructure market and government policies.

Implementation of Wireless Micro-Magnetic Detection System in the Conveyer Belt (컨베어 이송장치에서의 무선 미소자기감지 시스템 구현)

  • Lee, Young-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.2975-2981
    • /
    • 2014
  • Micro-magnetic detection system is used to detect small particles in an automatic transmission valve body, which signal noise and time-delay may occurs in process of signal transmitting and filtering. In this paper, we present the design and implement of a micro-magnetic detection system based on wireless sensor networks in conveyer belt. Micro-magnetic detection system consists of five modules which are magnetic sensor detector, signal processing unit, wireless sensor networks, system control unit and system monitoring unit. Our experimental results show that the proposed wireless micro-magnetic detection system improves both accuracy and time delay compared to the wired system; therefore, it may apply for wireless micro-magnetic detection system by analysis of packet reception rate.

Identification Technition of Malicious Behavior node Based on Collaboration in MANET (MANET에서 협업기반의 악의적인 노드 행위 식별기법)

  • Jeon, Seo-In;Ryu, Keun-Ho
    • The KIPS Transactions:PartC
    • /
    • v.19C no.2
    • /
    • pp.83-90
    • /
    • 2012
  • MANET(Mobile Ad-Hoc Network) has a weakness from a security aspect because it operates where no wired network is built, which causes the exposed media, dynamic topology, and the lack of both central monitoring and management. It is especially difficult to detect and mitigate a malicious node because there is not a mediator which controls the network. This kind of malicious node is closely connected to the routing in the field of study of Ad-Hoc security. Accordingly this paper proposes the method on how to enhance the security for the safe and effective routing by detecting the malicious node. We propose MBC(Identification technition of Malicious Behavior node based on Collaboration in MANET) that can effectively cope with malicious behavior though double detecting the node executing the malicious behavior by the collaboration between individual node and the neighbor, and also managing the individual nodes in accordance with the trust level obtained. The simulation test results show that MBC can find the malicious nodes more accurately and promptly that leads to the more effectively secure routing than the existing method.

DSP-Based Micro-Modem for Underwater Acoustic Communications (DSP 기반 초소형 수중 음향통신 모뎀)

  • Lee, Dongsoo;Lee, Sangmin;Park, Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.275-281
    • /
    • 2014
  • Recently, the need for various underwater application systems targeting efficient resource exploration and aquatic ecosystem monitoring is rapidly increasing in littoral sea and inland waters. In this paper, we focus on the research and development of digital module of acoustic micro modem which can be used for underwater mobile communication systems and underwater sensor network systems. Specifically, a digital module of acoustic modem embedding digital signal processor is designed and implemented. On top of the developed hardware platform, physical layer frame generation and recovery and channel coding algorithms are mounted and tested in a water tank and a pond to verify its functionality and performance. According to experimental results, less than 1 percent of total computational power is consumed in the processing of frame control and convolutional code with the data rate of 1 kbps. Thus, the performance of micro modem could be improved by loading efficient baseband algorithms into the processor while maintaining the implemented hardware.

An Empirical Study on Machine Learning based Smart Device Lithium-Ion Cells Capacity Estimation (머신러닝 기반 스마트 단말기 Lithium-Ion Cell의 잔량 추정 방법의 실증적 연구)

  • Jang, SungJin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.797-802
    • /
    • 2020
  • Over the past few years, smart devices, including smartphones, have been continuously required by users based on portability. The performance is improving. Ubiquitous computing environment and sensor network are also improved. Due to various network connection technologies, mobile terminals are widely used. Smart terminals need technology to make energy monitoring more detailed for more stable operation during use. The smart terminal which is light in small size generates the power shortage problem due to the various multimedia task among the terminal operation. Various estimation hardwares have been developed to prevent such situation in advance and to operate stable terminals. However, the method and performance of estimating the remaining amount are not relatively good. In this paper, we propose a method for estimating the remaining amount of smart terminals. The Capacity Estimation of lithium ion cells for stable operation was estimated based on machine learning. Learning the characteristics of lithium ion cells in use, not the existing hardware estimation method, through a map learning algorithm using machine learning technique The optimized results are estimated and applied.

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

Effect of medis composition on the Cordycepin and content Nutritional Components of Cordyceps militaris (배지 조성이 번데기 동충하초의 영양성분 및 Cordycepin 함량에 미치는 영향)

  • Cho, Soo-Muk;Park, Hong-Ju;Seo, Geon-Sik;Hong, Jong-Deok
    • The Korean Journal of Mycology
    • /
    • v.37 no.2
    • /
    • pp.161-166
    • /
    • 2009
  • The purpose of the present study is to develop a simple, fast and sensitive LC/MS method for simultaneous separation and the determination of an active component in the oriental medicinal mushroom Cordyceps militaris. Based on this work, the contents of cordycepin in Cordyceps militaris fruiting cultivated on various media were determined and compared. And also, the nutritional components such as minerals and vitamins were determined in order to provide useful information to consumer as a food material. The analysis methods of nutritional components were chosen on the basis of AOAC. The optimum separation for cordycepin was achieved using a solvent gradient consisting of the mixture of 0.1% formic acid in methanol (solvent B) in a background of 0.1% formic acid in water (solvent A) as a mobile phase and a 3.0${\times}$150 Waters XTera column. Selective ion monitoring (SIR) mode ([M+H]+ at m/z 252) was used for quantitative analysis of cordycepin. The cultivated Cordyceps militaris on various media contained 1~14 /g of cordycepin, 0.65~1.08% of thiamine, 0.86~7.17% of riboflavin, and 3.01~5.26% of niacin. The content of mineral components varied on categories, especially contained 500~3500% of potassium as a major mineral. Cordycepin, niacin and potassium were found much higher in the fruiting cultivated with soy power media (gold 10) than other media.