• 제목/요약/키워드: Mobile Medical Device

검색결과 109건 처리시간 0.021초

이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정 (Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device)

  • 홍선숙;김득용
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Medical Diagnosis Algorithm Based on Tongue Image on Mobile Device

  • Zhou, Zibo;Peng, Dongliang;Gao, Fumeng;Leng, Lu
    • Journal of Multimedia Information System
    • /
    • 제6권2호
    • /
    • pp.99-106
    • /
    • 2019
  • In traditional Chinese medical (TCM) science, tongue images can be observed for medical diagnosis; however, the tongue diagnosis of TCM is influenced by the subjective factors of doctors, and the diagnosis results vary from person to person. Quantitative TCM tongue diagnosis can improve the accuracy of diagnosis and increase the application value. In this paper, digital image processing and pattern recognition technologies are employed on mobile device to classify tongue images collected in different health states. First, through grayscale integral projection processing, the trough is found to localize the tongue body. Then the tongue body image is transferred from RGB color space to HSV color space, and the average H and S values are considered as the color features. Finally, the diagnosis results are obtained according to the relationship between the color characteristics and physical symptoms.

종합병원 진단용방사선장비의 고장유형 분석 (Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital)

  • 이우철;김정래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF

모바일 헬스케어 기반의 환자 모니터링 시스템 구현 (Implementation of Patient Monitoring System based on Mobile Healthcare)

  • 김경목
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권12호
    • /
    • pp.1-10
    • /
    • 2012
  • 본 논문에서는 모바일 헬스케어 시스템에 적합한 환자모니터링 시스템을 제안한다. 모바일 헬스케어 시스템은 스마트폰과 같은 모바일 장치를 사용하기 때문에 휴대가 간편한 소형 컴퓨팅 장치로 구성되어 있으며, 기존 컴퓨터에서 수행하던 작업을 수행할 수있다. 환자의 생체정보를 이동통신망환경에서 의료진과 환자 및 환자 가족의 스마트폰으로 실시간으로 전달할 수 있도록 TinyOS 기반의 의료용 메시지 구조를 설계하였으며 NesC를 사용하여 HBE-Ubi-ZigbeX에 포팅 하였다. 의료진과 환자 및 환자 가족이 스마트폰을 통하여 실시간으로 확인 할 수 있도록 안드로이드 기반의 환자 정보 모니터링 애플리케이션을 구현하여 일상생활에서 사용되고 있는 스마트폰에서 동작을 확인함으로써 생체정보의 원활한 송수신을 확인하였다.

PXA255기반 의료정보 고속 전송 시스템에 관한 연구 (A Study on High Speed Transmission System of Medical Information Based on PXA255)

  • 한영재;유호준;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.386-389
    • /
    • 2006
  • 미래 유비쿼터스 환경에 적합한 플랫폼은 모바일이면서 대용량 데이터를 자유롭게 송수신할 것이다. 그런 가운데 의료분야에서는 센서와 멀티미디어 기술의 발달에 발맞춰 개인이 휴대할 수 있는 휴대용이나 재택형 의료기기가 더욱 발전될 것이다. 그러한 다양한 의료기기 정보를 손쉽게 교환하고 전송하는 헬스케어용 단말기 또한 발전될 것이다. 이에 본 논문에서는 현재 모바일기기에 강력한 프로세서인 PXA255를 기반으로 이동성과 속도를 보장하는 WLAN을 연결하여 모바일 플랫폼에서의 의료 정보 전송을 통하여 효율적인 서비스를 위한 시스템을 제공하는데 중점을 두었다.

  • PDF

의료용 모바일 X선 장치의 개발 (Development of Mobile X-ray equipment for medicine)

  • 김태곤;김영표;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.762-763
    • /
    • 2010
  • 의료에 사용되는 X선 장치는 안정적인 전원이 공급되는 곳에 설치되어 사용되어지는 고정형과 환자가 있는 장소로 이동하여 촬영이 가능한 이동형으로 구분된다. 이동형 X선 장치에 대표적으로 사용되는 모바일 X선 장치는 공간상의 제약을 벗어나 매우 유용하게 사용이 가능하다. 하지만 고전압의 발생이 어려워 X선의 출력이 낮은 주로 손과 발의 촬영에 주로 응용된다. 본 연구에서는 인체의 진단영역에 제한을 가지지 않는 대용량의 모바일 X선 장치를 설계, 제작하여 부하변동에 따른 기기의 동작 특성을 확인하였다.

  • PDF

Mobile Healthcare System Based on Bluetooth Medical Device

  • Kim, Jeong-Heon;Lee, Seung-Chul;Lee, Boon-Giin;Chung, Wan-Young
    • 센서학회지
    • /
    • 제21권4호
    • /
    • pp.241-248
    • /
    • 2012
  • Recently healthcare industry such as pharmaceutical, medical device and healthcare service technology is growing significantly. Mobile healthcare has attracted big attention due to IT convergence technology. Paradigm of healthcare has been changed from the 1st generation(communicable disease prevention) and the 2nd generation(treatment of disease due to extended life expectancy) to the 3rd generation(extended life expectancy due to prevention and control). In our study, we suggest the 3rd generation mobile healthcare system using Bluetooth based wearable ECG monitoring system and smart phone technology. The mobile healthcare system consists of wearable shirts with Bluetooth communication module, ECG sensor, battery, and mobile phone. The ECG data is obtained by a miniaturized sensor and the data is transferred to a mobile phone using Bluetooth communication. Then, user can monitor his/her own ECG signal on an application using Android in mobile phone. The Bluetooth communication device is used due to highly reliable data transmission property and the Bluetooth chip is embedded in every mobile phone. The wearable shirts with chest belt of Bluetooth ECG module is designed with a focus on convenience in the daily life of a wearer. The ECG signal evaluation software in Android based mobile phone is developed for the health check and the ECG signal variation is tested according to the activities of the wearer such as walking, climbing stairs, stand up and sit down, and so on.

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

u-헬스케어 서비스 제공을 위한 사용자 맞춤형 모듈러 디바이스 설계 (User-Specific Reconfiguable Modular Device for u-Healthcare Services)

  • 김지호;송오영
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1689-1694
    • /
    • 2012
  • In this paper, we present a reconfigurable mobile platform (RMP) for user-specific applications. The RMP consists of a basic module and more than one extended module that offers specified functions to a portable platform based on the circumstances and purposes of the users. The extend module for specified purposes is connected to the basic module using a common interface that offers interoperability to the traditional interfaces. This paper gives the results of a survey to determine specifications of a reconfigurable mobile platform. Utilizing the results of the survey, we propose a prototype of the reconfigurable mobile platform to enable specialized functions. The design objective is to provide specialized functions required for user specific needs related to their age and physical condition. In addition, it can be used for mobile healthcare applications that are efficient in improving the user's health conditions by executing medical analysis and prescriptions.

User-friendly Application for operability with HL7 in mobile agent of Ubiquitous Health Environment

  • 이정훈;곽동엽;문강남;토니 사하마;김정태
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.866-870
    • /
    • 2009
  • Mobile Health (M-Health) system is a recent term for medical and public health practice supported by mobile devices, such as mobile phones, PDAs, and other wireless devices. Mobile Health system has been successfully establishing at few general hospital in Korea. However, to use diverse devices manufactured by various company cause inoperability, and lack of security disappoints customers often. Although the outstanding health environment, most of hospitals are unavailable to share electronic patient records due to lack of standard protocol to handle the interoperability each other. Health Level 7 (HL7) is the best solution for the problem. In this paper, we will analyse a current M-Health service in terms of security and mobile device, and suggest iPhone for the best device against hospital environment. Also, for keep confidentiality of health information and patient privacy, enhanced security mechanism is introduced. As a consequence, interoperable standard, and most appropriate device for supporting staffs and M-Health performance, and enhanced securirty mechanism will be integrated in order to propose improved M-health model.

  • PDF