• Title/Summary/Keyword: Mobile Content Design

Search Result 219, Processing Time 0.021 seconds

Effects of interactivity and usage mode on user satisfaction, usefulness, and intetion to use in text information presentation in mobile environment (모바일 환경에서의 텍스트 표현 방식의 상호작용성과 사용모드가 사용자의 만족도, 유용성, 사용의도에 미치는 영향)

  • Baek, Hyunji;Lee, Sangwon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.223-226
    • /
    • 2017
  • With the development of information technology, users are provided with information they want through mobile device in various situations. When users communicate with information, there is interaction through gesture activities such as tapping and experience in the process. Experience through interaction in mobile affect the user's psychology. This is important because it is related to the behavior of the user in the future. Various types of information presentation methods have been researched in mobile environment. However, there are more research focusing on functional interactivity. The purpose of this study is to investigate the effect of interaction and usage mode on satisfaction, usefulness, and intention to use for sound text presentation that is user-centered. As variables for my study, there are two factors which are interactivity and usage mode. The interactivity type is composed of two ways that are: High and Low depending on modality and message interactivity; and the usage mode is composed of Action mode and Goal mode depending on whether user has a task or not. The experimental design is $2{\times}2$. The same content is provided in (a) only Modality interactivity, and (b) Modality and Message interactivity are provided. Depending on usage mode, (a) Action mode is processed without a specific task, and (b) Goal mode is performed with a specific task to participants. The experimental study demonstrated that there is a difference in satisfaction, usefulness, and intention to use depending on the difference of interaction and usage mode when providing information in mobile environment. The results of this study are summarized as follows: interaction and usage mode have significant influence on mobile user's satisfaction, usefulness, intention to use.

  • PDF

An Improvement of Interoperability for HD-Class VOD Content Management System Based on H.264 (H.264 기반 HD급 VOD 콘텐츠관리시스템 상호운용성 개선)

  • Min, Byung-Won
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.315-320
    • /
    • 2014
  • Recently, although the requirement of quality of VOD content has been transferred upto the class of HD, conventional management systems characterized by OS dependency are truly limited in quality of video image, stability, and compatibility of network environments. In addition most of the content management systems realize very limited capabilities for the real affairs of content management and distribution services in such an OS dependent environment. In this paper, we propose a new scheme of HD-Class VOD Content Management System to solve these problems. We design and implement the proposed system based on open sources by using H.264 video compression method. The proposed system offers high quality content management method based on opened systems and independent on-line distribution method so that it can be realized as an integrated management scheme for VOD contents. Moreover, our system solves the problems of occasional cutting-down video, small screen, and poor image quality that exist in the conventional wmv-type CMS. According to the result of performance evaluation, our system maintains sufficient performance and tolerence for the case of large scale HD content operations or fabrications. We expect that the proposed integrated DB scheme will especially be effective when the content management applications are changed from Internet Web environments to mobile terminal environments.

Study on floating action button's use and its application (Floating Action Button의 사용 실태와 올바른 사용법)

  • Kang, Hyo Jin;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.17 no.4
    • /
    • pp.261-266
    • /
    • 2019
  • The purpose of this study is to assess usage of floating action button, a component of Google's Material Design. Case studies were conducted to overview the component's current usage and qualities, followed by eye-tracking experiments and in-depth interviews conducted to 12 subjects. Results have shown that while floating button can promote an action by catching viewers' attention with its striking visual, users tend to look at top more, thus preferring top placement for interfaces. To give positive user experience, designers should consider factors such as the amount of content covered by the button, the way users interact with the application, etc. This study aims to provide proper guidelines for the component's application.

Multi Parameter Design in AIML Framework for Balinese Calendar Knowledge Access

  • Sukarsa, I Made;Buana, Putu Wira;Yogantara, Urip
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.1
    • /
    • pp.114-130
    • /
    • 2020
  • Balinese calendar is defined as a unique calendar system for combining solar-based and lunar-based system and assuming local system. It is considered as guidance of Balinese societies' activities management, starting from meeting arrangement, wedding ceremony, to religious ceremonies. Practically, it has developed in the form of printed Balinese calendar and electronic Balinese calendar, either web or mobile application. The core of the function is to find out the day with its various characteristics in the Balinese Calendar. In general, society usually asks the religious leader to find out the day in detail. The technology of NLP combined with models of pattern discoveries supports the arrangement of the interaction model in searching the good day in Balinese Calendar to equip the conventional searching system in the previous applications. This study will design a dialog model with AIML method in multi-parameter basis; therefore, the users will be dynamically able to use the searching content in various ways by chatting in similar with consulting to a religious leader. This model will be applied in a chatbot basis service in telegram machine. The addition of the context recognition section into 4 paterns has been successfully improve the ability of AIML to recognize input patterns with many criteria. Based on the testing with 50 random input patterns obtained a success rate of 92.5%.

A Study on the Characteristics of Methods for Experiencing Contents and Network Technologies in the Exhibition space applied with Location Based Service - Focus on T.um as the Public Exhibition Center for a Telecommunication Company - (위치기반서비스(LBS) 적용 전시관의 콘텐츠 체험방식과 기술특성에 관한 연구 - 이동통신 기업홍보관 티움(T.um)을 중심으로 -)

  • Yi, Joo-Hyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.173-181
    • /
    • 2010
  • Opened on November 2008, as the public exhibition center of a telecommunication company, T.um is dedicated for delivering the future ubiquitous technologies and business vision of the company leading domestic mobile communication business to the global expected clients and business partners. Since the public opening, not only over 18,000 audiences in 112 nations have been visiting T.um, but also the public media have been releasing news regarding the ubiquitous museum constantly. By the reasons, T.um is regarded as a successful case for public exhibition centers. The most distinguished quality of the museum is established by the Location Based Service technology in the initial construction stage. A visitor in anyplace of T.um can be detected by digital devices equipped GPS systems. The LBS system in T.um allows visitors to get the information of relevant technologies as well as the process of how to operating each content at his own spots by smart phone of which wireless network systems make it possible. This study is focusing on analyzing and defining the T.um special qualities in terms of technologies to provide the basic data for following exhibition space projects based on LBS. The special method of experiencing contents can be designed by utilizing the network system applied to T.um in the planning stage.

Assessing the Effectiveness of Smartphone Usage to Interact with Learning Materials in Independent Learning Outside of Classrooms among Undergraduate Students

  • Sununthar Vongjaturapat;Nopporn Chotikakamthorn;Panitnat Yimyam
    • Asia pacific journal of information systems
    • /
    • v.31 no.1
    • /
    • pp.43-75
    • /
    • 2021
  • Clearly, the smartphone is increasingly playing a greater role in everyday life, thus providing opportunities to evaluate how well the use of the smartphone meets the requirements of undergraduate students in independent learning outside of a classroom setting. This study used the task-technology fit (TTF) model to explore the effectiveness of smartphone usage to interact with learning materials in independent learning outside of classrooms, the need for smartphone support, and the fit of devices to tasks as well as performance. First, the study used interviews, observation, and survey data to identify what are the most important constructs of smartphones that stimulate students to interact with learning materials in independent learning outside of classrooms. Based on the findings from the exploratory study and Task Technology Fit theory, we postulated the Navigation design, Ergonomic design, Content support, and Capacity as the essential dimension of the smartphone construct. Then, we proposed a research model and empirically tested hypotheses with the structural model analysis. The results reveal a significant positive impact of task and technology on TTF for smartphone usage to interact with learning materials in independent learning outside of classrooms; it also confirmed the TTF and performance have a direct effect on actual use.

A System for Supporting The Cyber Security Control of I&C System (제어계측 시스템 환경에서의 사이버 보안 통제 지원 시스템)

  • Jung, Hyun-Mi;Kim, Seok-Hun;Sung, Kyung
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.4
    • /
    • pp.442-448
    • /
    • 2013
  • I&C (Instrumentation & Control) system is different from information system and the security design of the two systems are also different. The modeling activity is needed based on the security control guide in order to build I&C system security control. In this paper, the role and by the security control, we designed the relationship (that is, the relation schema) between the documents for 'The system for supporting the cyber security control of I&C system design' based on the security control guide. The designed schema plans 'The system for supporting the cyber security control of I&C system' for observing the security control guide, and is used as the database and content that supports its design and implementation. The process and system of the proposed schema is utilized and designed. The design of the schema and system is intensified in the design phase with the proposed mode and supporting the I&C system cyber security design.

Validation of an HPLC Method for the Pharmacokinetic Study of Glipizide in Human (글리피짓 체내동태 연구를 위한 혈청 중 글리피짓의 HPLC 정량법 검증)

  • Cho, Hea-Young;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.137-142
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of glipizide in human serum was validated and applied to the pharmacokinetic study of glipizide. Glipizide and internal standard, tolbutamide, were extracted from human serum by liquid-liquid extraction with benzene and analyzed on a Nova Pak $C_{18}\;60{\AA}$ column with the mobile phase of acetonitrile-potassium dihydrogen phosphate (10 mM, pH 3.5) (4:6, v/v). Detection wavelength of 275 nm and flow rate of 0.7 ml/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed glipizide concentration (500 ng/ ml) with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-1000 ng/ml with correlation coefficient greater than 0.999. The lower limit of quantitation using 0.5 ml of serum was 10.0 ng/ml, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 82.6 to 105.0% for glipizide with overall precision (% C.V.) being 1.13-13.20%. The percent recovery for human serum was in the range of 85.2 93.5%. Stability studies showed that glipizide was stable during storage, or during the assay procedure in human serum. The peak area and retention time of glipizide were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of glipizide in human serum samples for the pharmacokinetic studies at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fexofenadine in Human (테르페나딘 체내동태 연구를 위한 혈청 중 펙소페나딘의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.437-443
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of a major metabolite of terfenadine, fexofenadine, in human serum was developed, validated, and applied to the pharmacokinetic study of terfenadine. Fexofenadine and internal standard, haloperidol were extracted from human serum by liquid-liquid extraction with acetonitrile and analyzed on a $Symmetry^{TM}$ C8 column with the mobile phase of 1% triethylamine phosphate (pH 3.7)-acetonitrile (67:33, v/v, adjusted to pH 5.6 with triethylamine). Detection wavelength of 230 nm for excitation, 280 nm for emission and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fexofenadine concentration (50 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 10 ng/mL, which was sensitive enough for the pharmacokinetic studies of terfenadine. The overall accuracy of the quality control samples ranged from 95.70 to 114.58% for fexofenadine with overall precision (% C.V.) being 3.53-14.39%. The relative mean recovery of fexofenadine for human serum was 90.17%. Stability studies (freeze-thaw, short-term, extracted serum sample and stock solution) showed that fexofenadine was stable during storage, or during the assay procedure in human serum. However, the storage at $-70^{\circ}C$ for 4 weeks showed that fexofenadine was not stable. The peak area and retention time of fexofenadine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fexofenadine in human serum samples for the pharmacokinetic studies of orally administered Tafedine tablet (60 mg as terfenadine) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Etodolac in Human (에토돌락 체내동태 연구를 위한 혈청 중 에토돌락의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jai-Dong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.265-271
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of etodolac in human serum was developed, validated, and applied to the pharmacokinetic study of etodolac. Etodolac and internal standard, ibuprofen were extracted from human serum by liquid-liquid extraction with hexane/isopropanol (95:5, v/v) and analyzed on a Luna C18(2) column with the mobile phase of 1% aqueous acetic acid-acetonitrile (4:6, v/v). Detection wavelength of 227 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed etodolac concentration $(1\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-40\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 0.05 ${\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.00 to 110.00% for etodolac with overall precision (% C.V.) being 1.08-10.11%. The percent recovery for human serum was in the range of 76.73-115.30%. Stability studies showed that etodolac was stable during storage, or during the assay procedure in human serum. The peak area and retention time of etodolac were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of etodolac in human serum samples for the pharmacokinetic studies of orally administered Lodin XL tablet (400 mg as etodolac) at three different laboratories, demonstrating the suitability of the method.