• Title/Summary/Keyword: Mixture concentration

Search Result 2,093, Processing Time 0.024 seconds

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

The influential Investigation and Surface Change by Concentration to the Antimicrobial Agent and Insecticide on Metallic Material (항균·방충제의 농도에 따른 금속재질에 미치는 영향성 및 표면변화 조사)

  • Lee, Jae Hui;Cho, Nam Chul;Lee, Sang Bae
    • Journal of Conservation Science
    • /
    • v.31 no.4
    • /
    • pp.361-372
    • /
    • 2015
  • The experiment attempts to find out the effect of the mixture of the antimicrobial agent and insecticide on metallic material including Silver(99.9%), Copper(99.9%), Lead(99.9%) and Iron(99.5%) by Oddy test. The mixtures of the antimicrobial agent and insecticide were prepared in 60ml; with the standard concentration of 17.5% in B77 Essential oil mixture, one for mixture of concentration of ${\pm}1{\sim}2%$ and insect repellent material; the other for mixture of low concentration and antimicrobial agent(BS-2 and BS-3) material. After Oddy test, we investigated the variation in the surface of the samples by visual inspection, weighing, color measurement and SEM-EDS analysis. The result showed that Lead had the biggest change in the surface, and Copper had the biggest change in the color. In addition, changes in the samples before and after the experiment were found to be greatest at concentration of 19% of Essential oil mixture of the antimicrobial agent and insecticide. Also, B78 Essential oil mixture produce change in samples. It means when the concentration of oil mixture rises, the variation of the samples gets bigger. And, the low concentration of mixture including B77 Essential oil mixture and B78 Essential oil mixture also produce big change in the samples. However, the low concentration of B77 Essential oil mixture that do not contain B78 Essential oil mixture was able to confirm that the change of the surface is not large.

Correlations of Oil Concentration Prediction during In-line Flow of $CO_2/Oil$ Mixtures (유동중인 $CO_2$냉매와 오일 혼합물의 농도 예측을 위한 상관식)

  • Park, Keun-Seo;Kang, Byung-Ha;Park, Kyoung-Kuhn;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.718-725
    • /
    • 2007
  • In the general vapor-compression refrigeration system, refrigeration lubricant circulates in refrigeration system with refrigerant. Knowledge of the amount of circulating lubricant is very important to exactly calculate capacity of the refrigeration system. An experimental study was conducted to estimate the oil concentration of a flowing $CO_2/Oil$ mixtures. POE and PAG oil are considered as test lubricants in this study. Performance tests were conducted under simulated liquid conditions for $CO_2/POE$ oil mixture in oil concentration of 0 to 10 weight-percent and $CO_2/PAG$ oil mixture in oil concentration of 0 to 6 weight-percent in the temperature ranges of $-5^{\circ}C\;to\;15^{\circ}C$. The results obtained indicate specific gravity of $CO_2/Oil$ mixture is increased as oil concentration is increased and as temperature of mixture is decreased. Oil concentration correlation of $CO_2/POE$ oil mixture and $CO_2/PAG$ oil mixture is suggested, based on the measurement of specific gravity and temperature. This correlation enable to predict the oil concentration without extraction of the mixture and can be applied for $CO_2/POE$ mixtures and $CO_2/PAG$ mixtures.

An investigation on the in si.tu measurement of the oil-concentration

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.20-28
    • /
    • 2001
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method is to extract the working mixture and then to measure the oil weight. In this study, oil concentration is measured in si.tu way without any extraction of the working fluid. Based on the measurement, a working equation is presented as follows, C=a +b x t +c x $t^2$ +(d + e x t +f x $t^2$) x SG. C is oil concentration, t is temperature($^{\circ}C). SG Is specific gravity of mixture and a~f is coefficients The oil concentration ranges over 0~l2 wt% and the temperature ranges over 20~50$^{\circ}C. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/P0E oil liquid mixtures.

  • PDF

An investigation on the in si.tu measurement of the oil-concentration

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.80-88
    • /
    • 2000
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method is to extract the working mixture and then to measure the oil weight. In this study, oil concentration is measured in si.tu way without any extraction of the working fluid. Based on the measurement, a working equation is presented as follows, C=a +b x t +c x $t^2$ +(d + e x t +f x $t^2$) x SG. C is oil concentration, t is temperature($^{\circ}C). SG Is specific gravity of mixture and a~f is coefficients The oil concentration ranges over 0~l2 wt% and the temperature ranges over 20~50$^{\circ}C. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/P0E oil liquid mixtures.

  • PDF

UV emission characteristics of Ne+$N_2$ gas-mixture discharges in AC Plasma Display Panel

  • Baek, Byung-Jong;Hong, Sang-Min;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.586-589
    • /
    • 2002
  • The Ultra Violet(UV) emission characteristics of Neon + Nitrogen gas-mixture discharge was investigated in AC plasma display panel. The firing voltage of Ne+$N_2$ gas-mixture discharge increased with increasing nitrogen concentration. The UV intensity emitted from the gas discharge also increased with increasing nitrogen concentration. The UV efficiency increase with increasing $N_2$ partial pressure at low $N_2$ concentration, and then UV efficiency is saturated at high $N_2$ concentration.

  • PDF

An Experimental Study on the Oil Circulation in an Inverter-Driven Heat Pump (인버터 열펌프내 오일순환량에 관한 실험적 연구)

  • 민만기;홍기수;황윤제;황일남;김철민;조관식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.717-724
    • /
    • 2000
  • It is important to investigate characteristics of flow of refrigerant/oil mixture circulating in a refrigeration system. Therefore the oil concentration in refrigerant/oil mixture should be measured exactly by the adequate measuring instrument. In this paper, the oil concentration was measured by density monitoring system(DMS) in the liquid-line of a inverter-driven heat pump. Experimental result follows ; the main factor that have an effect on oil concentration refrigerant/oil mixture circulating in a refrigeration system is the momentum and kinematic viscosity of refrigerant/oil mixture compressed by scroll compressor.

  • PDF

An investigation on the in si·tu measurement of the oil-concentration with densimeter (밀도계를 이용한 비추출식 냉동기유농도 측정에 관한 연구)

  • Kim, S.H.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.31-37
    • /
    • 1999
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method to measure the oil concentration is to extract the working mixture and then to measure the oil weight. However, it is Quite necessary to estimate oil concentration without any extraction of the working fluid. In this study a new method and working equation is presented as follows. It is based on the measurement of spedific gravity and temperature : $$C=a+b{\times}t+c{\times}t^2+(d+e{\times}t+f{\times}t^2){\times}SG$$ C is oil concentration, t is temperature($^{\circ}C$), SG is specific gravity of mixture and a~f is coefficients. The oil concentration ranges over 0~12 wt% and the temperature ranges over $20{\sim}50^{\circ}C$. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/POE oil oiquid mixtures.

  • PDF

Sensory Property Improvement of Jokbal (Korean Pettitoes) Made from Frozen Pig Feet by Addition of Herbal Mixture

  • Hwang, Young-Jung;Hwang, Seol-A;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.36 no.1
    • /
    • pp.19-22
    • /
    • 2016
  • This study was conducted to improve sensory quality of Jokbal (Korean Pettitoes) made from frozen pig feet by addition of herbal mixture (glasswort, raspberry and Sansa powders). After adding herbal mixture, lipid oxidation (2-thiobarbituric acid values, TBARS), sensory property, and textural property were determined. Herbs were individually added into cooking soup at concentration of 6% (low concentration treatment, LCT) or 12% (high concentration treatment, HCT) of raw pig feet. Refrigerated pig feet were used as control. Thawed feet without any herbal mixture were used as freezing treatment (FT). TBARS in LCT or HCT were lower than that in FT, and showed the similar to that in Control. Addition of the herbal mixture was effective in improving the flavor and textural property of thawed feet by inhibiting lipid oxidation and protein denaturation in a dose-dependent manner.

Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging (표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발)

  • Jeong, Chan Ho;Lee, Hyung Ju;Choi, Chang Kyoung;Lee, Hyoungsoon;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.