• Title/Summary/Keyword: Mixer

Search Result 1,118, Processing Time 0.033 seconds

A Monolithic 5 GHz Image Reject Mixer for Wireless LAN applications

  • Ho-Young Kim;Jae-Hyun Cho;Jung-Ho Park
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12B
    • /
    • pp.1733-1740
    • /
    • 2001
  • A monolithic 5 GHz image reject mixer using a 0.5-m GaAs MESFET technology is designed and simulated. The Mixer exhibits a 13.56 dB down-conversion gain, a SSB (Single SideBand) noise figure of 11.91 dB, an input IP3 (third order intercept point) of -3.73 dBm and a PldB (1-dB compression point) of -11.0 dBm. The critical issue in the image reject mixer is the phase accuracy and magnitude balance of the 90 phase shifting network. The proposed image reject mixer realizes a 90 phase shifter on chip. This phase shifting network does not need any phase adjusting to achieve the phase error specification of 3 over a frequency range from 800 MHz to 1GHz. The simulated overall image rejection ratio is better than 50 dB.

  • PDF

Numerical Analysis Study of the Mixing Mechanism of Non-element Mixer (논 엘레멘트 믹서의 혼합 메커니즘에 관한 수치해석적 검토)

  • You, Sun Ho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Visualization of the mixing pattern in a non-element mixer was carried out using laser induced fluorescence(LIF) to evaluate characteristics of mixer consisting of the main flow pipe and branch flow pipes. The branch flows were injected periodically with the period $T_{in}$ normal to the main flow, and rhodamine B was mixed into the most upstream branch flow to visualize mixing pattern in the main flow pipe by LIF. The length of boundary line L of the LIF image was measured. In this study, a numerical analysis was performed to identify the mixing process of the non-element mixer, and the results were compared with experimental results. Each result was almost the same. When the number of branch flows is increased, the mixing pattern became complicated and was supposed to become chaotic. The length of boundary line L increased exponentially with an increase in the number of branch flows.

Low Spurious Image Rejection Mixer for K-band Applications

  • Lee, Moon-Que;Ryu, Keun-Kwan;Kim, Hyeong-Seok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.272-275
    • /
    • 2004
  • A balanced single side-band (SSB) mixer employing a sub-harmonic configuration is designed for up and down conversions in K-band. The designed mixer uses anti-parallel diode (APD) pairs to effectively eliminate even harmonics of the local oscillator (LO) spurious signal. To reduce the odd harmonics of LO at the RF port, we employ a balanced configuration for LO. The fabricated chip shows 12$\pm$2dB of conversion loss and image-rejection ratio of about 20dB for down conversion at RF frequencies of 24-27.5GHz. As an up-conversion mode, the designed chip shows 12dB of conversion loss and image-rejection ratio of 20 ~ 25 dB at RF frequencies of 25 to 27GHz. The odd harmonics of the LO are measured below -37dBc.

Characteristics of coagulants dispersion within In-Line Orifice Mixer (In Line Orifice Mixer에서의 응집제 확산분포 특성)

  • Lim, Kyeong-Ho;Park, Young-Oh;Park, Dae-Jin;Park, No-Suk;Ko, Tae-Kon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.689-696
    • /
    • 2008
  • In a water treatment process a complete and homogeneous dispersion of the coagulants in the raw water could be most important factor. This research was performed to evaluate coagulation performance of the in-line-orifice mixer which was recently introduced as a rapid mixing device. The test was to determine the actual coagulant dispersion distribution on the overall cross-section at a distance of 1.6~3D from the chemical injection point by measuring zeta potential. From the results of zeta potential test, it was shown that the coagulant dispersion within the in-line orifice mixer was occurred very unevenly. The results have confirmed that it is necessary to increase the velocity of coagulants injection or pressurized water rates, in order to reduce nonuniform distribution of chemicals.

An Experimental Study of Temperature Profiles in Mixing Zone of AHU with an Air Mixer (에어믹서가 설치된 공조기 혼합실 내의 온도분포에 관한 실험적 연구)

  • Pak, Kwon-Jong;Lee, Sek-Jun;Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.999-1006
    • /
    • 2006
  • A study of temperature profiles in mixing zone of AHU (air handling unit) can contribute greatly to enhance performance of AHU system, so the study on the temperature distribution between RA (return air) and OA (outdoor air) is important to analyze the mixing characteristics in a mixing zone of AHU. Accordingly, the temperature profiles during RA (return air) and OA (outdoor air) supply process into mixing zone of AHU with an air mixer are studied experimentally. The effect of air mixer, OA temperature and RA/OA flow rate are studied in detail. In this study, the results show that the mixing efficiency is all high for installed the air mixer. The more OA temperature increase and OA flow rate decrease, the more mixing efficiency is high.

Industrial Accident Compensation Insurance Coverage and Industrial Accidents among Concrete Mixer Truck Drivers (콘크리트믹서트럭운전자의 산재보험 적용과 산업재해)

  • Kim, Min Ji;Choi, Eunsuk
    • Korean Journal of Occupational Health Nursing
    • /
    • v.29 no.2
    • /
    • pp.106-113
    • /
    • 2020
  • Purpose: This study aimed to analyze industrial accident compensation insurance coverage and industrial accidents among concrete mixer truck drivers. Methods: Original data on industrial accidents from 2012 to 2017 were analyzed through descriptive statistics. Results: Industrial accident compensation insurance coverage was 44.6% in 2017. Most concrete mixer truck drivers were affiliated with small businesses. A total of 61 industrial accidents occurred in 2012, 65 in 2014, and 80 in 2017. The major types of industrial accident were falls, slips, and crushes. Conclusion: Because concrete mixer truck drivers are at high risk for industrial accidents, industrial accident compensation insurance coverage and industrial accident prevention should be strongly enforced.

Single Balanced Monolithic Diode Mixer using Marchand Balun for Millimeter-wave Applications

  • Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.127-130
    • /
    • 2012
  • In this paper, we reported on a single balanced monolithic diode mixer using Marchand balun for millimeter-wave applications. The single balanced monolithic mixer was fabricated using drain-source-connected pseudomorphic high electron mobility transistor (PHEMT) diodes considering the PHEMT MMIC full process. The average conversion loss is 16 dB in the RF frequency range of 81~86 GHz at LO frequency of 75 GHz with LO power of 10 dBm. The RF-to-LO isolation characteristics are greater than -30 dB and the total chip size is $1.0mm{\times}1.35mm$.

Design of CMOS Mixer improved Flicker Noise and Conversion Gain (Flicker Noise와 변환 이득 특성을 개선한 CMOS Mixer설계)

  • Lim, Tae-Seo;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1508-1509
    • /
    • 2007
  • 본 논문에서는 TSMC 0.18um공정을 이용한 무선통신 수신기용 직접변환 방식의 Double Balanced Mixer를 설계 하였다. 제안된 mixer는 current bleeding기법과 내부에 인덕터를 추가하여 기존의 Gilbert Cell구조의 mixer에 비해 변환 이득과 Flicker Noise특성을 향상 시켰다. 모의실험결과 2.45GHz에서 11dB의 변환이득을 나타내었으며 Flicker Noise의 corner frequency는 510kHz이고 이때 잡음특성은 10.8dB이다. 이 회로의 동작전압은 1.8V이며 소모 전력은 8.8mW이다.

  • PDF

Study on visualization of water mixing flows in a digester equipped with a vertical impeller by using radiotracers

  • Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen;Lim, Jae Cheong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.170-177
    • /
    • 2020
  • A mixer with a new concept design has been adapted into water treatment plants. It reportedly cuts down the energy consumption of the mixer by the new mixer, which moves vertically and creates internal flows toward its bottom. However, no experimental observations have been made on the internal flow caused by a vertical impeller. In this study, a radiotracer experiment, radioactive particle tracking (RPT) technique, and particle image velocimetry (PIV) were carried out to visualize the flow in the mixer, and compared to each other. The results show that the flow patterns from these techniques are very similar to each other, and the performance of the mixer was good enough to mix the inner materials.

ADINA/FSI Analysis of Petrochemical Plant Column Mixer (화학 플랜트용 칼럼믹서의 ADINA/FSI 해석)

  • Lee, Won-Suk;Jung, Goo-Choong;Choi, Yeon-Sun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.213-219
    • /
    • 2007
  • Column mixer Is one of the facilities to mix fluids at petrochemical plants. The vibration of column mixer is usually caused by pumps for fluid inflow and mixing of inside fluids. This fluid induced nitration is mainly responsible for the reduction of column life. Measurements were performed for understanding the vibration characteristics of the column. First measurement results showed the need of stiffness reinforcement. After the reinforcement work, second measurement confirmed the difference between two results. Modal analysis was also performed to investigate the resonance of the column vibration and the damage of the rib plate. To confirm fluid induced vibration at the column mixer fluid structure interaction analysis using ADINA/FSI was performed, which showed the necessity of the modification of the rotary valve.