• 제목/요약/키워드: Mixed-mode column

검색결과 18건 처리시간 0.028초

역궤적 이동경로별 용인지역의 컬럼에어로졸 특성 (Columnar Aerosol Properties at Yongin According to Transport Paths of Back Trajectories)

  • 박지수;최용주;김영성
    • 한국대기환경학회지
    • /
    • 제33권2호
    • /
    • pp.97-107
    • /
    • 2017
  • Columnar aerosol properties retrieved from solar radiation were investigated at the Yongin (YGN) SKYNET site over seven years from October 2008 to October 2015. Hourly averages were calculated when the data were available, and back trajectories were calculated to examine the effects of regional transport. Data recovery rate was low at 6.6%, primarily because solar radiation was measured only under daytime clear-sky conditions. Mean values of the fine-mode volume fraction (FMVF) as well as its seasonal variation were similar to those of $PM_{2.5}/PM_{10}$ although the coarse-mode fraction of column aerosols tended to be slightly larger. The values of single scattering albedo (SSA) and FMVF were lower in spring due to the effects of mineral dust, and higher in summer due to secondarily-formed inorganic ions. Back trajectories were grouped into five clusters according to the directions of transport paths. Aerosol loading was highest for Cluster 2 from the northwest, but SSA and FMVF were not particularly high or low because aerosols were composed of various materials with different properties. Aerosol loading was lowest for Cluster 5 from the Pacific Ocean passing through the south end of Japan, whose SSA and FMVF were highest as secondarily-formed inorganic ions were mixed.

기체 방전관의색상 제어에 관한 연구 (A Study on Color Control in Gas Discharge Tube)

  • 이종찬;청야정명;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.285-288
    • /
    • 1996
  • The electronic operation of the gas discharge tube is controlled by the electrical energy as sinusoidal waveform in arbitrary frequency range, or as a sequence of pulses at a wide range of duty cycle, the gas composition, the kind of electrode and the vessel geometry. In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of IIg-Ne ( 10 Torr ), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency and pulse width in high voltage. As increasing pulse width and frequency in the gas discharge tube, the phenomenons that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist. The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing pulse width and frequency. The changing method of pulse width and frequency has been shown to be suitable for the luminous color control.

  • PDF

LC-MS/MS를 이용한 베타락탐계 항생제와 베타차단제의 동시분석 (Simultaneous analysis of β-lactam antibiotics and β-blockers by LC-MS/MS)

  • 손보영;김준일;안치화;이수원;김복순;정득모
    • 분석과학
    • /
    • 제29권4호
    • /
    • pp.179-185
    • /
    • 2016
  • 물 시료 중에 잔류하는 β-차단제 3종(아테놀롤, 메토프롤롤, 프로프라놀롤)과 β-락탐계 항생제 6종(아목시실린, 페니실린G, 세파클러, 세파드록실, 세파렉신, 세프라딘)을 다른 두 종류의 카트리지를 사용하여 효과적인 분석방법을 정립하였다. 고분자 친수성-친유성 균형 카트리지(Hydrophile-lipophile balance, HLB)와 강한 양이온 교환 혼합 모드인 고분자 흡수 카트리지(Mixed mode cation exchange, MCX)를 사용하여 자동고체상 추출장치(Solid-phase extraction, SPE)로 전처리를 하였다. 충분한 크로마토그래피 분리를 위해 XDB-C18 (1.8 μm; 3.0 mm × 100 mm) 컬럼을 사용하였다. 정량을 위한 검정곡선의 상관계수(r²)가 0.995 이상으로 우수한 직선성을 나타내었다. 방법검출한계(Method detection limits, MDL)와 정량한계(Limit of quantitation, LOQ)는 각각 1.1~3.9 ng/L와 5~13 ng/L이었다. 이 분석방법으로 한강으로 유입되는 지천과 원수를 실태 조사 한 결과 N.D.~0.209 μg/L 농도로 검출되었다.

동해에서 경험직교함수 기법을 이용한 수온과 소나성능 변화 연구 (A study on the variations of water temperature and sonar performance using the empirical orthogonal function scheme in the East Sea of Korea)

  • 나영남;조창봉;손수욱;한주영
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.1-8
    • /
    • 2024
  • 수동형 소나의 성능을 측정하기 위해 주어진 환경과 시스템 변수 하에서 보통 최대 탐지거리를 고려한다. 음파가 해표면 또는 해저면과 필연적으로 접촉하는 천해에서는 표적탐지가 최대 탐지거리까지 유지되는 게 일반적이다. 그러나 심해에서는 음파가 해표면 또는 해저면과 접촉하지 않을 수도 있으며, 이 경우 음파가 도달하지 않는 음영구역이 존재할 수도 있다. 이 경우 최대 탐지거리만으로 각 소나의 탐지성능을 완전하게 기술하기 어려울 수 있다. 보다 완전한 탐지성능 기술을 위해 '탐지견고성(Robustness Of Detection, ROD)' 개념을 도입하고자 한다. 동해 연안에서 수괴의 공간적 분포와 최대 탐지거리 및 탐지견고성은 밀접한 관계가 있으며, 최대 탐지거리와 탐지견고성은 서로 반대의 공간적 변동을 보인다. 경험직교함수(Empirical Orthogonal Function, EOF)를 도입하여 수온의 시공간적 분포를 분석한 결과 첫 번째 모드는 전형적인 계절 변화를 보이고, 두 번째 모드는 혼합층 등의 세기 변화를 반영하는 것으로 추정된다. 이 두 모드가 전체 변화의 약 92 %를 설명한다. 수심 5 m와 100 m 표적을 가정하여 수동형 소나의 최대 탐지거리와 두 모드의 계절 변화의 상관관계를 분석하면 첫 두 모드와 높은 음의 상관계수(약 -0.9)를 보인다. 수온의 계절적 변화는 표층 ~ 수심 200 m에서 발생하며, 이에 따라 수심 100 m에 표적이 존재한다고 가정하여 수동소나를 수심 100 m 이상에서 운용할 경우 계절변화가 미미한 탐지성능을 기대할 수 있다.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권5호
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

고층건물의 자연 진동실험 및 시스템판별 (Ambient Vibration Testing and System Identification for Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제16권3호
    • /
    • pp.23-33
    • /
    • 2012
  • 구조물의 특성치를 결정하기 위하여 18층 규모의 사무용 건물 3동에 대하여 자연진동 조건하에서 동적계측실험을 수행하였다. 대상건물은 기본적으로 보-기둥 골조시스템에 횡하중을 보다 효율적으로 지지하기 위하여 추가적으로 코아가 배치된 혼합 구조형식을 나타낸다. 매층 마다 측정한 일련의 진동기록으로부터 고유진동수, 모드형태 및 감쇠율 등과 같은 모달계수를 추출하기 위하여 최신 주파수- 및 시간영역-기반 응답의존 시스템판별법인 FDD, pLSCF 및 SSI를 적용하였다. 3방법에 의하여 추출한 결과는 대체로 일치하였으나, 초기 FE 해석결과와 비교하여 저차 3개 고유진동수는 대략 1.2~1.7배나 되는 단단한 거동을 나타냈다. 진동응답으로부터 추출된 값, 기준에서 제시하는 약산식 및 FE해석에 의하여 산정된 고유주기를 비교하여 보면, FE결과가 가장 유연한 거동을 예측하였으며, 높이를 변수로 하는 약산식이 추출된 값에 가장 근접한 결과를 나타냈다. 이러한 차이는 현재의 실험 추출치에는 콘크리트 균열 등과 같은 강성저감 요인을 포함하고 있지 않으며, 또한 FE 해석치는 비구조체 및 사용된 재료의 실제성능 등과 관련된 강성증가 요소를 포함하고 있지 않기 때문이다.

고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정 (Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography)

  • 박대진;이성곤;김우미
    • 생명과학회지
    • /
    • 제22권11호
    • /
    • pp.1456-1462
    • /
    • 2012
  • 소라페닙은 멀티카이네즈 억제제로서 신세포암, 전이성 간세포암 환자의 치료에 효과가 입증된 경구용 항암제이다. 이 연구의 목적은 고속액체크로마토그래피 텐덤질량분석기법(LC/MS/MS)을 이용하여 사람 혈장 내 소라페닙의 농도를 측정하는 효율적인 방법을 개발하고 한국식품의약품안전청(KFDA) 기준에 따라 분석법을 검정하는 것이다. 혈장시료($100{\mu}l$)에 내부표준물질인 chlorantraniliprole을 첨가한 후 이소프로필알콜과 에틸아세테이트로 구성(1:4, v/v)된 0.1% 포름산 함유 추출용액을 혼합하였다. 원심분리 후 상층액을 취하여 원심감압농축하였다. 잔사를 이동상에 재용해하고 Waters사의 역상 XTerra$^{TM}$ C18 칼럼(입자크기 $3.5{\mu}m$)을 장착한 고속액체크로마토그래피 장치에 주입하였다. 액체크로마토그래피는 0.1% 포름산과 10 mM 암모늄 포메이트를 함유한 버퍼용액과 메탄올, 아세토나이트릴을 각각 1:6:3으로 혼합한 용액을 이동상으로 사용하였으며 5분 내에 측정을 완료하였다. 분석대상 물질들은 텐덤질량분석기에서 electrospray 양이온 이온화($ES^+$) 검출방식으로 확인하였으며 소라페닙은 'm/z 465.2 ${\rightarrow}$ 252.5', chlorantraniliprole은 'm/z 484.4 ${\rightarrow}$ 286.2'으로 구성한 multiple reaction monitoring 방법을 사용하였다. 검정 결과, 2-5,000 ng/ml의 농도 구간에서 양호한 직선성($r^2$ > 0.99)과 정확도(90.7-103.9%), 정밀도(10% 이하)를 나타내었다. 새롭게 개발된 LC/MS/MS을 이용한 사람 혈장 내 소라페닙의 농도 측정법은 KFDA 기준을 만족하였으며, 기존의 방법에 비해 민감도가 높은 방법이었다.

식품 중 타르색소의 동시분석 및 계통분석을 위한 HPLC 분석조건 및 정제과정 확립 (Optimization of HPLC Method and Clean-up Process for Simultaneous and Systematic Analysis of Synthetic Color Additives in Foods)

  • 박성관;홍연;정용현;이창희;윤혜정;김소희;이종옥
    • 한국식품과학회지
    • /
    • 제33권1호
    • /
    • pp.33-39
    • /
    • 2001
  • 이온쌍고속액체크로마토그래피를 이용하여 현재 우리나라에서 식품에 사용이 허용된 타르색소 8종과 일본등 외국에서는 허용되어 있으나 우리나라에서 허용되어 있지 않은 11종 등 총 19종의 동시 및 계통분석법을 확립하였다. HPLC에 사용한 컬럼은 Symmetry $C_18$, 이동상은 0.01 M TBA-Br이 함유된 0.025 M 초산암모늄용액-아세토니트릴-메탄올(65 : 25 : 10)과 0.01 M TBA-Br이 함유된 0.025 M 초산암모늄용액-아세토니트릴-메탄올(40 : 50 : 10)를 구배용매조성법(gradient mode)으로 사용하였다. 자외선 검출기의 파장은 동시분석의 경우 254 nm, 계통분석은 황색계통 420 nm, 적색계통 520 nm 그리고 청색 및 녹색계통은 620 nm로 설정하였다. 이때 색소들의 검출한계는 적색계통이 $0.05\;{\mu}g/g$, 황색계통은 $0.03\;{\mu}g/g$, 청색 및 녹색계통은 $0.01\;{\mu}g/g$이었다. Sep-pak $C_18$을 이용한 색소의 정제 방법은 혼합색소표준용액의 pH를 $5{\sim}6$으로 조정하고 0.1% TBA-Br을 가하여 색소를 보유시킨 다음 0.1% 염산-메탄올로 색소를 용출하여 HPLC로 분석하였다. 19종의 타르색소를 동시분석하는데 35분이, 계통분석시에는 18분 정도가 소요되었고 두 경우 모두 양호한 분리를 보였다.

  • PDF