• 제목/요약/키워드: Mixed-bed

검색결과 223건 처리시간 0.023초

Electrostatic Charging Measurement and PVC Separation of Triboeletrostatically Charged Plastic Particles using a Fluidized Bed Tribocharger

  • Shin, Jin-Hyouk;Lee, Jae-Keun
    • 한국분무공학회지
    • /
    • 제7권2호
    • /
    • pp.7-15
    • /
    • 2002
  • A particle flow visualization, electrostatic charging measurement and separation of triboelectrically charged particles in the external electric field by a fluidized bed tribocharger are conducted for the removal of PVC particles from mixed waste plastics. The laboratory-scale triboelectrostatic separation system consists of the fluidized bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PET particles can be imparted negative and positive surface charges respectively due to the difference of triboelectric charging series between particles and particles in the fluidized bed tribocharger, and can be separated by passing them through an external electric field. To visualize these charged particles, He-Ne laser is used with cylindrical lenses to generate a sheet beam. In the charging measurement, the particle motion analysis system (PMAS), capable of determining particle velocity and diameter. is used to non-intrusively measure particle behavior in high strength electric field. The average charge-to-mass ratios of PVC and PET particles are $1.4\;and\;1.2{\mu}C/kg$, respectively. The highly concentrated PVC (91.9%) can be recovered with a yield of about 96.1% from the mixture of PVC and PET materials for a single-stage processing. The triboelectrostatic separation system using the fluidized tribocharger shows the potential to be an effective method for removing PVC from mixed plastics for waste plastic recycling.

  • PDF

Study on dryout heat flux of axial stratified debris bed under top-flooding

  • Wenbin Zou;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.636-643
    • /
    • 2024
  • The coolability of the debris bed with a simulant of solidified corium is experimentally studied, focusing on the effects of the structure of the axial stratified debris bed on the dryout heat flux (DHF). DHF was obtained for the four structures with different particle sizes for the axial stratified debris bed under top flooding. The experimental results show that the dryout position of the axial stratified debris bed is formed at the stratified interface indicated by the temperature rise, and the DHF of the axial stratified bed is much lower than that of the homogeneous bed packed with the upper small particles. To predict the dryout heat flux of the stratified debris beds, by considering the properties of the mixed area, a one-dimensional dryout heat flux model of the porous medium is derived from a water and vapor momentum equation for porous medium, two-phase permeability modifications, interfacial drag, and the correlation between capillary pressure and liquid saturation and verified with the experimental data. The modified model can give reasonable results under different structures.

E.V.A., 고무폐기물 소각에 따른 폐가스 처리의 연구 (Combustion Characteristics of E.V.A., Rubber Waste Treatment by Fixed-Bed Incinerator.)

  • 배병훈;장성호;임경택
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.221-227
    • /
    • 1996
  • The objectives of this study are to examine combustion characteristics of E.V.A. and rubber wastes by fixed-bed incinerator, The results are as follows. Combustion temperature with time rises rapidly, and mass of E.V.A. reduces at short time in E.V.A. combustion. In variation of air-fuel ratio (m), ice ideal values of m of E.V.A. and rubber are 2.5, 1.5 respectively. Mixed-waste combustion is more economic than single E.V.A. combustion, because we can get high combustion efficiency (94.0~99.0%) at 2.0 air-fuel ratio of mixed-waste combustion. Removal efficiencies of SO2 at cooling tower are about 20%. The combustion efficiencies of rubber are over 98.0% according to the experimental conditions.

  • PDF

바이오매스 연료의 연소 특성 실험 (A Experiment of Combustion Behavior of Biomass Fuels)

  • 김학덕;김영대;송주헌
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.503-511
    • /
    • 2018
  • There have been many studies of combustion in the circulating fluidized bed. However, little study is available for combustion of wood pellet together fed with wood chip. The mixed ratio of two fuels is an useful information when thermal power company would receive the Renewable Energy Portfolio Standard (RPS) from government. In this study, the combustion behavior and kinetics of such biomass fuels are evaluated using fluidized bed reactor and thermogravimetric analyzers. The mixing ratio of wood chip relative to wood pellet was varied at different temperatures. The results show that a combustion reactivity changed significantly at the wood chip mixing ratio of 40%, particularly at low temperature condition.

Iron hydrolysis and lithium uptake on mixed-bed ion exchange resin at alkaline pH

  • Olga Y. Palazhchenko;Jane P. Ferguson;William G. Cook
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3665-3676
    • /
    • 2023
  • The use of ion exchange resins to remove ionic impurities from solution is prevalent in industrial process systems, including in the primary heat transport system (PHTS) purification circuit of nuclear power plants. Despite its extensive use in the nuclear industry, our general understanding of ion exchange cannot fully explain the complex chemistry in ion exchange beds, particularly when operated at or near their saturation limit. This work investigates the behaviour of mixed-bed ion exchange resin, saturated with species representative of corrosion products in a CANDU (Canadian Deuterium Uranium) reactor PHTS, particularly with respect to iron chemistry in the resin bed and the removal of lithium ions from solution. Experiments were performed under deaerated conditions, analogous to normal PHTS operation. The results show interesting iron chemistry, suggesting the hydrolysis of cation resin bound ferrous species and the subsequent formation of either a solid hydrolysis product or the soluble, anionic Fe(OH)3-.

Fluidized Bed Drying Effect on the Aerogel Powder Synthesis

  • Hong, Seong-Hoon;Lee, Dong-Kyu;Oh, Chang-Sup;Kim, Yong-Ha
    • 에너지공학
    • /
    • 제21권1호
    • /
    • pp.43-46
    • /
    • 2012
  • A fluidized bed drying approach was utilized to the synthesis of water glass based silica aerogel powders. The effects of the fluidized bed drying conditions such as the superficial velocity and temperature of hot air and bead size as well as bead/wet-gel ratio, on the physical properties such as tapping density and productivity of the aerogel powders were systematically investigated. The experimental results showed that the amount of beads mixed with wet-gels in the fluidized bed column has the most profound impact on the fluidization efficiency, greatly enhancing the yield of the aerogel powders up to 98% with a proper bead/wet-gel weight ratio as compared to 72% without using beads. No significant change was observed in the tapping density over a wide range of the fluidized drying condition. Consequently the fluidized bed drying approach shows a good promise as an alternative route for the large-scale production of the aerogel powders.

유동층전극 반응기를 이용한 폐수내의 중금속 회수 (Electrolytic recovery of metals from the plating rinse water with fluidized bed electrode reactor)

  • 이제근;전해수
    • 한국표면공학회지
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 1984
  • The fluidized bed electrode reactor(FBER) with conducting particles has been made use of the removal of metals from dilute electroplating rinse water. The electrolysis was carried out under the conditions of diaphragm current density with 2~28A/$dm^2$ and bed expansion with 20~50%. Recirculating batch operations have been shown that the metal concentration dropped exponentially and may be taken down to 10 ppm. And then, the current efficiency at a concentration of 10 ppm copper was 37% under the conditions of 30% bed expansion and 6 A/$dm^2$, and at concentrated electrolyte (2000ppm copper) was over 80% in the range of 8~28A/$dm^2$ and 20~50% bed expansion. One of the technical possibilities of fluidized bed electrolysis is the separation of copper and nickel from a mixed solution of copper and nickel.

  • PDF

온실을 중심으로 토양 성분에 따른 세이보리의 생육현황에 대하여 (A Study on the Growth of Savory According to the Composition of the Soil Inside a Green House)

  • 신경순;조태동
    • 한국환경과학회지
    • /
    • 제30권1호
    • /
    • pp.87-96
    • /
    • 2021
  • Herb has been categorized as a special plants from the beginning of human history and used in different medical systems in different cultures. This research has classified soil into 6 kinds that have diverse elements to see to which various kinds of savory(satureja hortensis) adapt well, experimenting from sowing to flowering for around 13 weeks, and also divided indoor conditions to get the result below. In conclusion, growth status of savory depending on the kinds of soil suggest that in indoor conditions the savory if planted in ⑤ bed soil compounded with saprolite and poultry manure grew better than any other condition. On the other hand, the growth status was bad in ① masato, ② clay, ④ bed soil mixed with saprolite, and ⑥ bed soil mixed with clay conditions. Though you can see the immediate effect of soil on the growth of savory, I'd like to reveal the details of how elements of savory operate in which kind of soil and outdoor conditions the goal of this research, in the next research.

유동층연소로에서 유연탄과 무연탄의 연소특성 해석 (Analysis of Combustion Characteristics of Bituminous and Anthracite Coal in a Fluidized Bed Combustor)

  • 장현태;박태성;홍성창
    • 공업화학
    • /
    • 제10권4호
    • /
    • pp.586-591
    • /
    • 1999
  • 유연탄과 무연탄 및 유, 무연탄의 연소특성을 해석하기 위하여 내경 0.109 m의 유동층반응기에서 회분석 석탄주입에 따른 유동화특성과 연소특성 실험을 수행하였다. 온도변화곡선, 압력요동특성치를 이용하여 회분식유동층에서 유연탄과 무연탄 및 혼합석탄의 연소특성을 측정하였다. 유연탄과 무연탄의 입자크기, 두 석탄의 혼합비, 유동화매질의 입자크기에 따른 영향을 고찰하였다. 유연탄과 무연탄의 혼합연소시 무연탄의 혼합비가 30 %인 경우가 유연탄의 연소속도 및 연소거동이 최적으로 나타났다. 저품위 고회분 무연탄의 경우 유동화특성보다 연소특성에 의한 영향이 더욱 크게 나타났다. 또한 유동층의 유동화 특성에 의하여 연소거동이 변화됨을 알 수있었다.

  • PDF

실내실험에 의한 혼합사로 구성된 하상 표층에서 지형변동에 따른 유사의 분급 특성 분석 (Experimental Study on the Sediment Sorting Processes of the Bed Surface by Geomorphic Changes in the Alluvial Channels with Mixed Grain Size)

  • 장창래
    • 한국수자원학회논문집
    • /
    • 제47권12호
    • /
    • pp.1213-1225
    • /
    • 2014
  • 본 연구에서는 혼합사로 구성된 망상하천에서 사주의 변화와 하상토 분급현상을 실내실험을 통하여 파악하였다. 하상경사가 급한 하도에서 유사 유출량은 시간의 변화에 따라 매우 불규칙하지만, 경사가 완만한 하도에서 유사 유출량은 규칙적이고, 일정한 주기를 나타내었다. 또한 2중 퓨리에 해석을 통하여 지배적인 사주의 특성과 진폭을 분석하였다. 하상고가 상승하면 무차원 하상토 입경은 작아졌지만, 하상고가 저하되면 무차원 하상토 입경은 커졌다. 기층에서 무차원 한계소류력과 표층에서 무차원 한계 소류력의 비가 증가하면, 표층에서 평균입경과 무차원 하상토 중앙입경이 작아졌다. 또한 국부적으로 하상경사가 증가하면서, 유사의 선택적 이동에 의하여 하상토가 분급되고, 평면적으로 입경이 불균일하게 분포하는 분급 특성이 나타났다.