• Title/Summary/Keyword: Mixed working fluids

Search Result 10, Processing Time 0.027 seconds

The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe Using Mixed Working Fluid (혼합 작동 유체를 이용한 진동 세관형 히트 파이프의 압력 진동과 열전달 특성에 관한 연구)

  • Jeong, Hyeon-Seok;Kim, Jeong-Hun;Kim, Ju-Won;Kim, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.318-327
    • /
    • 2002
  • In this paper, heat transfer and pressure oscillation characteristics on oscillating capillary tube heat pipe(OCHP) according to input heat flux, mixture ratio of working fluid and inclination angle were investigated and were compared single working fluid(R-142b) with binary mixture working fluid(R-142b-Ethano1). OCHP was made to serpentine structure of loop type with 10 turns by drilling the channels of length 220mm, width 1.5mm, and depth 1.5mm on the surface of brass plate. In this study, R-l42b and R-l42b-Ethanol were used as working fluids, the charging ratio of working fluids was 40(vol.%), the input heat flux to evaporating section was changed from 0.3W/㎠ to 1.8W/㎠, and mixture ratio of working fluid was R(100%), R(95%)-E(5%), R(90%)-E(10%), and R(85%)-E(15%). From the experimental results, it was found that the effective thermal conductivity of single working fluid was better than that of binary mixture working fluid. But, in case of binary mixture working fluid, critical heat flux was higher than that of single working fluid. And, the higher the mixture ratios of working fluid, the lower heat transfer performance. In case of pressure oscillation, as the inclination angle was lower, pressure wave was more irregular. These phenomena were more serious when the working fluid was binary mixture. Besides, when mixture ratio was higher, saturated pressure was increased, more irregular wave was observed and the mean amplitude was increased. For the same input heat flux, inclination angle and charging ratio, when pressure oscillation has sinusoidal wave, mean amplitude was small, and saturated pressure was low value, the heat transfer was excellent.

Fluid dynamical characteristics of microencapsulated phase change material slurries (미립잠열슬러리의 유체역학적 특성연구)

  • 이효진;이승우;이재구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

Spectroscopic Measurement of Temperature Distribution in Some Plasma Jets (분광학적 방법에 의한 Plasma Jet의 온도분석 측정)

  • 전춘생;박용관;임명선
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.104-110
    • /
    • 1977
  • This paper investigates temperature distribution of plasma jets which used argon gas, and nitrogen gas mixed with argon as working fluids in spectroscopic method, and studies correlations between them main results are as follows; 1) The temperature at the center of plasma jet increases with are current and gas flow, and decreases with magnetic flux density along the axial direction. 2) The changing rate of temperature of plasma jet in the radial direction decreases rapidly beyond 2mm from central axis. 3) Temperature drop rate of plasma jet in the central axis direction appears most apparant beyond 13mm above the nozzle exit. 4) When argon gas mixed with a small amount of nitrogen, plasma temperature increases at same are current compared with the case of argon gas only.

  • PDF

Performance analysis of 20 kW OTEC power cycle using various working fluids (다양한 작동유체를 이용한 20 kW급 해양온도차 발전 사이클 성능 분석)

  • Yoon, Jung In;Ye, Byung Hyo;Heo, Jung Ho;Kim, Hyun Ju;Lee, Ho Saeng;Son, Chang Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.836-842
    • /
    • 2013
  • In this paper, the 20 kW Ocean Thermal Energy Conversion(OTEC) is newly proposed in order to select the refrigerant that makes the cycle performance be optimized and the performance of 20 kW OTEC applying 15 pure refrigerants and 16 mixed refrigerants is analyzed. The efficiency of system, the mass flow of working fluids and TPP, which is new concepts, are analyzed. In view of cycle efficiency, R32/R152a (87:13) is the highest efficiency among the refrigerants. At the mass flow of working fluid to make the 20 kW electricity, R717 is shown as the lowest value. And in view of TPP in this study, R32/R134a 70:30 is the most optimized refrigerant. The analysis can confirm that the refrigerant is different along with the part of the system, so it is necessary to select the optimized refrigerant for 20 kW OTEC.

A study on the solar assisted heating system with refrigerant as working fluid (냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구)

  • Kim, Ji-Young;Ko, Gawng-Soo;Park, Youn-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

Basic performance analysis of ocean thermal energy conversion using the refrigerant mixture R32/R152a (R32/R152a 혼합냉매를 적용한 해양온도차발전의 기초성능해석)

  • Cha, Sang Won;Lee, Ho Saeng;Moon, Deok Soo;Kim, Hyeon Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.502-507
    • /
    • 2014
  • In this paper, performance characteristics of cycles were studied when mixed working fluid was used for ocean thermal energy conversion (OTEC). Among the various mixed refrigerants for industrial heat-pump, R32/R152a used in ocean thermal energy conversion system. For simulations, R32/R152a were used in existing closed cycle and Kalina cycle which is used only ammonia and water as mixed refrigerant. Temperature of the warm heat source was 26 and 29 celsius degree, temperature of the cold heat source was 5 celsius degree. In results of simulation, Gross power of the closed cycle on R32 was 22kW, and efficiency of the cycle was 2.02%. When the mixed refrigerant of R32/R152a, in the ratio of 90 to 10, gross power of the closed cycle was 29.93kW, and efficiency of the cycle was 2.78%. Gross power and cycle efficiency of R32/R152a increased by 36% and 37% than those of existing single refrigerant. Additionally, the same simulations were conducted in Kalina cycle with the same various composition ratio of mixed refrigerant.

An Experimental Study of Cryochiller System Using Autocascade (오토캐스케이드 방식을 적용한 극저온 칠러 시스템의 실험적 연구)

  • Cha, Dong-an;Kwon, Oh-kyung;Yun, Jae-ho;Kim, Dae-yeol
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1980-1985
    • /
    • 2007
  • The purpose of this study is to investigate the performance of an autocascade refrigeration system using the refrigerant mixtures of R-134a(64${\sim}$72wt%), R-23(20${\sim}$25wt%) and R-14(8${\sim}$12wt%) as working fluids by experiment. The experimental apparatus consisted of a autocascade system with a compressor, condenser, evaporator, gas-liquid separator and cascade condenser, etc. Two main causes to this failure were considered as follows. First, the pressure ratio in the compressor was extremely increased at the beginning of the experiment. Second, the outlet temperature in compressor was higher than its limited temperature. For a stable operation of the compressor, a portion of the mixed refrigerant was by-passed at the inlet of the heat exchanger and transferred directly to the suction of the compressor in the modified system. The experimental parameters were changed weight of R-134a(1800g, 2800g), R-23(700, 800, 900g) and R-14(300, 400, 500g). The results showed that the best performance in case of R-134a of 2800g, R-23 of 900g and R-14 of 500g.

  • PDF

An Experimental Study on the Drop Size of a Twin-Fluid Swirl Jet Nozzle (이유체 선회분사 노즐의 액적크기에 관한 실험적 연구)

  • Oh, J.H.;Kim, W.T.;Kang, S.J.;Rho, B.J.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 1996
  • This experimental study was to investigate spray angles and drop sizes in an external mixed twin-fluid swirl jet nozzle. Twin-fluid swirl jet nozzle with swirlers designed four swirl angles such as $0^{\circ},\;22.5^{\circ},\;45^{\circ},\;64.2^{\circ}$ was employed. A PDA system was utilized for the measurement of drop size and mean velocity. Water and air were used as the working fluids in this experiment. The mass flow rate of water was fixed as 0.03 kg/min, and air flow rates were controlled to have the air/liquid mass ratio from 1.0 to 6.0. As a result, swirl angle controlled to spray angles and drop sizes. It was found that swirl angle was increased with spray angle and with decreased SMD. However, the effect of swirl angle was reduced at large air/liquid mass ratio(Mr=6.0).

  • PDF

Performance analysis of an organic Rankine cycle for ocean thermal energy conversion system according to the working fluid and the cycle (작동유체 및 사이클에 따른 해양온도차발전용 유기랭킨사이클의 성능분석)

  • Kim, Jun-Seong;Kim, Do-Yeop;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.881-889
    • /
    • 2015
  • Ocean thermal energy conversion is an organic Rankine cycle that generates power using the temperature difference between surface water and deep water. This study analyzes the thermodynamic efficiency of the cycle, which strongly depends on the working fluid and the cycle configuration. Cycles studied included the classical simple Rankine cycle, Rankine cycles with an open feedwater heater and an integrated regenerator, as well as the Kalina cycle. Nine kinds of simple refrigerants and three kinds of mixed refrigerants were investigated as the working fluids in this study. Pinch-point analysis that set a constant pinch-point temperature difference was applied in the performance analysis of the cycle. Results showed that thermodynamic efficiency was best when RE245fa2 was used as the working fluid with the simple Rankine cycle, the Rankine cycles with an open feedwater heater and an integrated regenerator, and when the mixing ratio of $NH_3/H_2O$ was 0.9:0.1 in the Kalina cycle. If the Rankine cycles with an open feedwater heater, an integrated regenerator, and the Kalina cycle were used for ocean thermal energy conversion, efficiency increases could be expected to be approximately 2.0%, 1.0%, and 10.0%, respectively, compared to the simple Rankine cycle.

Analyses of Steady State Mixing Process of Two-Liquids Using Artificial Intelligence (인공지능을 이용한 이종액체 정상 상태 혼합의 혼합과정 해석)

  • KONG, DAEKYEONG;YUM, JUHO;CHO, GYEONGRAE;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.523-529
    • /
    • 2018
  • Two liquids which are generally used as fuels of rockets are mixed and their mixing process is quantitatively investigated by the use of particle image velocimetry (PIV). As working fluids for the liquid mixing, Dimethylfuran (DMF) and JetA1 oils have been used. Since the specific gravity of DMF is larger than that of JetA1 oil, the DMF oil has been set at the lower part of the JetA1 oil. For better visualization of the mixing process, Rhodamin B powder has been blended into the DMF oil. An agitator having 3 blades has been used for mixing the two liquids. For quantitative visualization, a LCD monitor has been used as a light source. A color camera, camcoder, has been used for recording the mixing process. The images captured by the camcoder have been digitized into three color components, R, G, and B. The color intensities of R, G, and B have been used as the inputs of the neural network of which hidden layer has 20 neurons. Color-to-concentration calibration has been performed before commencing the main experiments. Once this calibration is completed, the temporal changes of the concentration of the DMF has been quantitatively analyzed by using the constructed measurement system.