• 제목/요약/키워드: Mixed refrigerant

검색결과 70건 처리시간 0.024초

마이크로핀관 응축기 내 냉매-냉동기유 혼합물의 전열 특성 (Condensation heat transfer for refrigerant-oil mixtures in microfin tube condenser)

  • 조금남;태상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.90-95
    • /
    • 2000
  • Condensation heat transfer experiments for R-22 and R-407C refrigerants mixed with mineral oil and POE oil respectively were performed in straight and U-bend sections of a microfin tube. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to $400 kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass flux decreased and inlet quality increased. The heat transfer coefficients in the U-bend were the maximum at the $90^{\circ}$ position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficients at the first straight section.

  • PDF

LNG-FPSO(Liquefied Natural Gas-Floating Production Storage and Offloading)용 질소 팽창 사이클의 효율 개선에 대한 연구 (Investigation on Efficiency Improvement of the Nitrogen Expander Cycle : Natural Gas Liquefaction Process for LNG-FPSO)

  • 백승환;정상권;김선영
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.442-447
    • /
    • 2010
  • FPSO (Floating Production Strorage and Offloading) method for LNG industry is efficient and facile compared to onshore NG (Natural Gas) treatment facility. Five simple natural gas liquefaction cycles for FPSO are presented and simulated in this paper. SMR (Single Mixed Refrigerant) cycle, SNE (Single Nitrogen Expander) cycle, DNE (Double Nitrogen Expander) cycle, PNE (Precooled Nitrogen Expander) cycle, and PDNE (Precooled Double Nitrogen Expander) cycle are compared. Simple analysis results in this paper show that precooling process and adding an expander in the liquefaction cycle is an effective way to increase liquefaction efficiency.

Miniature J-T cryocooler using argon and nitrous oxide mixture

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권4호
    • /
    • pp.38-42
    • /
    • 2008
  • Miniature J-T cryocooler using nitrogen or argon has been widely adopted in cooling infrared sensor for space/military application and cryosurgery. Argon or nitrogen, however, has relatively low specific cooling power compared to nitrous oxide, but the ultimate operating temperature is much lower than nitrous oxide. On the other hand, nitrous oxide has large specific cooling power, but the operating temperature is limited to its boiling point (>183K). To compromise the different characteristics of these gases, the performance of miniature J-T cryocooler using argon and nitrous oxide mixture is investigated in this paper. Three different compositions of mixture (25/75, 50/50, and 75/25 molar fraction) are blended and tested. The results are compared with the experiments of pure argon and pure nitrous oxide. The experimental results show some encouraging potentiality of mixed refrigerant J-T cryocooler. The critical clogging problem, however, was observed with argon and nitrous oxide mixture, and the lowest achievable temperature with this mixture was limited to the freezing point of nitrous oxide. The paper discusses detailed clogging process of the mixture and suggests an alternative.

다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석 (Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants)

  • 윤정인;허성관;제재면;전민주;손창효;문정현
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.82-88
    • /
    • 2015
  • In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.

냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구 (A study on the solar assisted heating system with refrigerant as working fluid)

  • 김지영;고광수;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

상용성 화학공정모사기를 활용한 혼합냉매 이용 냉동사이클의 전산모사 (Simulation of the Mixed Propane Refrigeration Cycle Using a Commercial Chemical Process Simulator)

  • 조정호;김영우
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3253-3259
    • /
    • 2009
  • 본 연구에서는 프로판이 주성분인 혼합냉매를 사용하여 프로세스의 온도를 $-20^{\circ}C$까지 낮추는 증기 재 압축을 활용한 냉동사이클에 대한 전산모사를 수행하였다. 냉매의 공급온도는 프로세스와의 온도차를 $10^{\circ}C$로 가정하여 $-30^{\circ}C$로 정하였다. 전산모사를 위한 열역학 모델식으로는 Peng-Robinson 상태방정식을 적용하였으며, 냉매 혼합물의 각 성분에 대한 순수성분의 온도에 따른 증기압을 잘 추산하기 위해서 새로운 Alpha function을 이용하였다. 한편, 냉매 혼합물의 각각의 이성분계 실험 데이터를 잘 추산하기 위한 혼합규칙으로는 van der Waals 혼합규칙을 사용하였다. 한편 전체공정의 전산모사를 위해서 Invensys사의 PRO/II with PROVISION 8.2를 활용하였으며, 압축기의 소요동력을 최소화시키기 위해서 2단 압축공정을 사용하였으며. 첫 번째 압축기 후단의 최적 압력은 6bar이며 이때 총 소요동력은 755.7kW임을 알 수 있었다.

GC/AED를 이용한 HFC-134a의 미량 불순물 분석 (Determination of trace impurities of HFC-134a by gas chromatograph with atomic emission detector (GC/AED))

  • 김명자;임정식;이진복;이정순
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.240-251
    • /
    • 2017
  • 1,1,1,2-수소불화탄소(HFC-134a)는 에어컨에 주로 사용되는 냉매로, 최근 온실가스로 규제되어 정제를 통한 재사용 방법이 권장되고 있다. 폐냉매의 재사용 기준 평가를 위해서는 폐냉매에 존재하는 미량 성분의 정량분석이 매우 중요하다. 본 연구에서는 표준 물질이 없어서 정량화하기 어려웠던 C, H, Cl, F가 포함된 미량 성분들을 GC/AED (gas chromatograph-atomic emission detector)를 이용하여 정량분석하였다. 이를 위하여 GC/MSD (mass selective detector)를 통한 정성분석을 선행하였다. 또한 성분의 원자 수와 비례하여 반응하는 AED의 특성을 조사하기 위하여, 탄화수소 혼합 표준물질을 이용하여 선형성을 확인하였다. 시료 중 C, H, Cl, F가 포함된 미량 성분의 정성 분석 결과, 주성분인 HFC-134a와 유사 냉매류들을 포함한 총 15 개의 성분이 검출되었다. MSD 결과를 토대로 AED를 이용한 미량 성분들을 정량 분석한 결과, 한 시료는 $CHClF_2$ 성분($45438.38{\mu}mol/mol$), 또 다른 시료는 $C_2H_2ClF_3$ 성분($1311.47{\mu}mol/mol$)이 가장 높은 몰분율을 나타냈다. 본 연구에서는 이 분석법을 기반으로 하여, 표준 물질이 존재하지 않아 정량화하기 어려운 복합 성분들의 정성 및 정량 분석의 확장 적용이 가능할 것으로 보인다.

공조용 압축기 축 거동 측정용 베어링 내장형 센서 (The built-in sensor bearing to measure shaft behavior of compressor for air-conditioning)

  • 김지운;안형준;김지영;한동철;윤정호;황인수
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.230-236
    • /
    • 2001
  • We developed a built-in sensor bearing to measure the rotor motion of a rolling piston type compressor for the air conditioner. Because of needs for the high efficiency and long life span of compressor, and the usage of alternative refrigerants, the operating condition of the compressor becomes more severe. The accurate measurement of the rotor motion of the compressor can contribute greatly to the design and analysis of the hydrodynamic bearing. However, it is difficult to measure accurately the shaft behavior of small compressor because of the small space for the sensor mount, high temperature and pressure of compressor, oil mixed with refrigerant, and electromagnetic noise of the motor. To overcome these difficulties, we develop the cylindrical capacitive sensor that is built in the hydrodynamic bearing and calibrate the built-in sensor bearing indirectly through measuring the oil relative permittivity. We measured the rotor motion as well as suction and discharge pressures in various conditions. The several experimental results show that the developed built-in sensor bearing can measure the rotor motion not only in steady state but also in transient state.

  • PDF

R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구 (An experimental investigation of thermodynamic performance of R-22 alternative blends)

  • 황의필;김창년;박영무
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

액화천연가스(LNG)를 사용한 수소 생산 및 액화 공정 개발 (Design and Analysis of Hydrogen Production and Liquefaction Process by Using Liquefied Natural Gas)

  • 노원준;박시환;이인규
    • Korean Chemical Engineering Research
    • /
    • 제59권2호
    • /
    • pp.200-208
    • /
    • 2021
  • 액체 상태의 수소는 기체 상태의 수소에 비해 수송이 용이하고 에너지 밀도가 높으며 폭발 위험성이 낮다. 하지만 수소 액화 공정은 냉각 사이클에 많은 양의 에너지가 소모된다. 반면에 액화천연가스(LNG; Liquefied Natural Gas)는 재기화 과정에서 다량의 냉열이 버려진다. 따라서 LNG 냉열을 회수하여 수소 냉각에 활용한다면 공정 효율을 높일 수 있다. 또한, 천연가스 개질을 통한 수소 생산은 가장 경제성 있는 방법으로 평가받고 있으며, 이러한 측면에서 LNG를 수소 생산의 원료로 사용할 수 있다. 본 연구에서는 LNG를 원료 및 냉열원으로 사용하여 수소를 생산 및 액화시키는 공정을 개발하고 열역학적 관점에서 공정을 평가하였다. 공정 개발을 위해 기존의 탄화 수소 혼합 냉매와 헬륨-네온 냉매를 이용한 수소 액화 공정을 비교 공정으로 선정하였다. 이후 LNG를 원료 및 수소 예냉의 냉열원으로 사용하는 새로운 공정을 설계하여 에너지 소모량 및 엑서지 효율 측면에서 기존 공정과 비교, 분석하였다. 제안된 공정은 기존 공정 대비 약 17.9%의 에너지 절감 및 11.2%의 엑서지 효율이 향상된 결과를 나타내었다.