• Title/Summary/Keyword: Mixed organic solvent

Search Result 104, Processing Time 0.025 seconds

A Study on Organic Solvent Exposure in Painting Operation of Automobile Manufacturing Industry (자동차 도장 작업장에서의 유기용제 폭로에 관한 연구)

  • 김영식
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.10-16
    • /
    • 1994
  • A Study was performed in order to measure mixed organic solvent concentrations in air of painting operations during January 5-28, 1991. The mixed organic solvent concentrations were analyzed by the gas chromatography. The results were as follows: 1. The detection of organic solvent was highest in aromatic hydrocarbon(68%), and followed by aliphatic hydrocarbon (18%), and ketone (14%). 2. The detection of organic solvent by component category was highest in the grid class solvent (79.4%), and followed by the 3rd class solvent (20.6%). 3. Number of cases exceeding TLVS of mixed solvent level in air was highest on dipping operation (44%), and followed by spray operation (40%), dry and washing operation (33%), and adhensive operation (12%).

  • PDF

The Type of Anemia in Organic Solvent Workers by MCV and RDW (MCV와 RDW를 이용한 복합유기용제 취급 근로자의 빈혈 유형에 관한 조사)

  • Kim, S.J.;Ohm, S.H.;Kim, D.H.;Lee, C.U.;Chun, J.H.;Kim, S.C.;Pae, K.T.;Park, H.J.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.2 s.38
    • /
    • pp.162-171
    • /
    • 1992
  • The hematologic effect by low-concentration and repeated exposure to mixed organic solvent remains obscure. This study was performed to evaluate the hematologic effect by mixed organic solvent exposure, especially on the type of anemia by mean corpuscular volume(MCV) and red blood cell distribution width(RDW). The subject were 64 organic solvent workers(male 4, female 60) and 78 general workers(male 18, female 60) who showed anemic tendency in worker's health examination which carried out by Pusan Paik Hospital from January to December, 1988. The author gained some hematologic findings(hemoglobin, hematocrit, RBC, WBC, MCV, MCHC, platelet count, ESR, RDW) from auto-analysis method by coulter counter S plus IV, and compared the type of anemia by MCV and RDW. In the pilot study for estimating the prevalence of anemia according to the type of b, the prevalence rate was higher in organic solvent workers than in public officials as 10.9% and 4.1% respectively. There were statistical significance in the value of hemoglobin, hematocrit, MCV, MCHC, platelet count, ESR, RDW between the two study groups with more severe anemic tendency in organic solvent workers. The type of anemia in organic solvent workers was microcytic and anisocytic with the mean value of $68.28{\pm}8.3fL$ of MCV and $19.1{\pm}4.0%$ of RDW.

  • PDF

A comparison of desorption efficiency by types of solvent for polar and non-polar organic compounds collected on activated charcoal tube (활성탄관에 포집된 극성 및 비극성 유기용제 분석시 탈착용매 종류에 따른 탈착효율 비교)

  • Son, Yonjoo;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.3-18
    • /
    • 1997
  • This study was conducted to evaluate desorption efficiencies by types of desorption solvent for polar and non-polar organic compounds collected on activated charcoal tubes. Analytes tested were toluene, m-xylene, isobutyl alcohol, n-butyl alcohol, cellosolve acetate, and butyl cellosolve. Three different concentration levels of spiked sample were made. Types of cosolvent mixed with the main solvent, $CS_2$, were methanol, pentanol, and dimethylformamide (DMF) and the cosolvent for methylenechloride was methanol. The amounts of cosolvent added to the main solvent were 1, 5, and 10% by volume (v/v%), respectively. The results were as follows: 1. For all mixed solvents except 1% methanol and 1% pentanol with $CS_2$, desorption efficiency significantly increased, compared with that of $CS_2$ alone. 2. Desorption efficiency increased by increasing analyte loading on charcoal tube regardless of mixed solvents used and the material polarity. 3. For all cosolvents mixed with $CS_2$ by 1% and 5% volume, desorption efficiency for non-polar compound was significantly higher than that of polar compound. For the 10% mixed solvents and the methylenechloride mixed with methanol, the results were opposite. 4. The lowest mean percent bias of 4.79% was obtained from the 5% DMF-$CS_2$ mixed solvent, followed by 4.82% from the 10% DMF-$CS_2$ solvent while the highest bias of 23.26% was from the solvent of $CS_2$ alone. Based on the results of this study, in order to increase desorption efficiency, it is recommended to add such cosolvents as methanol, pentanol, and DMF to $CS_2$, preferably 5% by volume for analyzing polar compounds collected in charcoal tubes.

  • PDF

The Dissociation Constant of Phenol Red Indicator in Mixed Solvents (혼합용매중의 지시약 Phenol Red의 해리정수)

  • 김양배
    • YAKHAK HOEJI
    • /
    • v.20 no.1
    • /
    • pp.41-43
    • /
    • 1976
  • The dissociation constant of phenol red indicator in mixed solvents was studied. Methanol and ethanol were employed as solvents and studied the changes of pK values of indicator according to the kind and concentration of organic solvent which is mixed into water solution. The effect of methanol solvent on pK is negligible at 40%, 60% and 80% mixing. While in the case of ethanol, the effect of above 40% mixing is not negligible.

  • PDF

A Study on the Effects of the Dissociation Constant of Edible Tar Pigment. I (혼합용매중(混合溶媒中)에서의 식용(食用) Tar색소(色素)의 해리정수(解離定數)에 관(關)한 연구(硏究) (제 1 보)(第 1 報) -2',4',5',7'- Tetraiodofluorescein Sodium염(鹽)에 대(對)하여-)

  • Kim, Bak-Kwang;Lee, Min-Hwa;Cho, Young-Mee;Kim, Kil-Su;Moon, Dong-Chul
    • Journal of Pharmaceutical Investigation
    • /
    • v.10 no.3
    • /
    • pp.14-19
    • /
    • 1980
  • The dissociation constant of erythrosine in the mixed solvent systems of water-alcohols and water-acetone at various pH and in concentration media were determined by spectrophotometric method. Methanol, ethanol, and acetone were employed as solvents and studied the changes of pK values of erythrosine according to the kind and change of concentration of organic solvent which is mixed into water solution. The effect of organic solvent on pK is negligible at 40% while in the case of above 40% mixing, it is not negligible.

  • PDF

A Study on the Mixed Organic Solvent Dose and Subjective Symptoms of Direct and Indirect Bonding workers in Shoes Manufacturing Industrial (신발제조업체의 접착제 사용에 따른 직접·간접폭로 근로자들의 복합유기용제 폭로량과 자각증상 비교)

  • Byun, Jeong-Sik;Kim, Jeong-Yun;Cho, Young-Chae;Kim, Dong-Hyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.48-58
    • /
    • 1995
  • This study was performed to find out the exposure level of mixed organic solvents, excretion of urinary hippuricacid and subjective symptoms according to the exposure of organic solvents of female workers who works on 5 shoes manufacturing industries in Taejon City from 24, september to 20, october 1993. The studied groups were divided into 3 groups that were consist of direct exposure group(48 workers), indirect exposure group(49 workers) and non-exposure group(68 workers) to the organic solvents. The exposure levels of toluene of direct exposure group which $89.86{\pm}56.20ppm$ had higher than that of indirect exposure group which had $40.23{\pm}47.21ppm$. In the exposure level of mixed organic solvent(R-value), direct exposure group was $2.84{\pm}1.53$ and exceeded approximatly 3 times the R-value. Whereas, indirect exposure group was not exceeded the R-value as $0.80{\pm}0.61$. In the excretion level of urinary hippuric acid, direct exposure group was $1.78{\pm}1.25g/l$, indirect exposure group was $1.22{\pm}0.93g/l$ and non-exposure group was $0.51{\pm}0.18g/l$ respectively. Therefore both direct exposure group and indirect exposure group were significantly higher than non-exposure group(P<0.01). In the correlation between toluene levels and urinary hippuric acid level, the direct exposure group had positive correlation(R=0.8309, P<0.01), also indirect exposure group had positive correlation(R=0.5859, P<0.05) and also in the correlation between the R value of mixed organic solvents and the urinary hippuric acid levels, the direct exposure group had positive correlation(R=0.4492, P<0.05), and indirect exposure group had ositive correlation(R=0.7911, P<0.01). In the complain rates of the worker's subjective symptoms at work, both direct exposure group and indirect exposure group were higher than non-exposure group(P<0.05, P<0.01). But the sujective symptoms of "floating sensation" of direct exposure group had significantly higher than indirect exposure group. In the percent of subjective symptoms complaints during the worker's daily life, both direct exposure group and indirect exposure group had generally more statistical significance than nonexposure group(P<0.01), direct exposure group had not statistical significant difference from indirect exposure group. As the results mentioned above, it has been analysed that the indirect at the adjacent manufaturing process are exposed to the considerable amount of solvent. Therefore, I think that there should be the betterment of surrounding through the complete working environment management to the occurrence source of the organic solvent, the changes of health management system to the indirect-exposed workers, and the systematic management of the special medical examination and the like.

  • PDF

Determination of Dissociation Constant of Hydrogen Cupferrate in Methanol-Water and 2-Propanol-Water Solution (Methanol-물 및 2-Propanol-물의 混合溶媒에서의 Hydrogen Cupferrate의 酸解離常數의 決定)

  • Si-Joong Kim;Chang-Ju Yoon;In-Soon Chang
    • Journal of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.119-128
    • /
    • 1966
  • The glass electrode was empirically calibrated in methanol-and 2-propanol-water mixed solvents, by means of which the pH-meter reading could be converted to stoichiometric hydrogen ion concentration. The thermodynamic dissociation constants of hydrogen cupferrate in methanol-and 2-propanol-water solution were potentiometrically determined with the changes in composition of organic solvents at 0.01 and 0.05 of the ionic strength and 25$^{\circ}C$. The empirical formula of the constants with mole fraction (n) of the organic solvent are as follow: methanol-water solution $pK_a$= 2.24n + 4.29 at ${\mu}$ = 0.01 n = 0.0476∼0.642 $pK_a$ = 2.35n + 4.38 at ${\mu}$ = 0.05 n= 0.0446~0.642 2-propanol-water solution $pK_a$= 5.50n + 4.48 at ${\mu}$ = 0.05 n = 0.0253~0.259 The relationships between $pK_a$ of acetic acid, propionic acid and HCup and dielectric constant of some mixed solvents were discussed. It would be considered that the factors effecting $pK_a$ value of weak acid in mixed-solvent are not only dielectric constants but acid-base character and solvation effect of the solvent, etc.

  • PDF

Racemization of Optical Active tris-Oxalatocobaltate (III) Ion in Mixed Solvants (혼합용매내에서 광학활성인 tris-Oxalatocobaltate (III) ion의 라세미화에 관한 연구)

  • Dong Jin Lee;Doh Myung Ki
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.377-382
    • /
    • 1986
  • Racemic tris-oxalatocobaltate (III) complex ions were optically resolved by an optical active complex, ${\Delta}$-tris-ethylenediamine cobalt (III), and then racemization of ${\bigwedge}-[Co(ox)_3]^{3-}$ obtained was investigated in various mixed solvent such as water-organic solvent (organic solvents=ethanol, iso-propyl alcohol, acetone, and dioxane). The rate of racemization was increased with following order; water < ethanol < acetone < isopropyl alcohol < dioxane; which is the same order for polarizability of organic solvent added. Considering ${\Delta}H^{\neq},\;{\Delta}S^{\neq}$ and above facts for the racemization of ${\bigwedge}-[Co(ox)_3]^{3-}$, it seems to be twist mechanism of plausible mechanisms.

  • PDF

Study on the Cleaning Screen Printing using Alternative Cleaning Solvent of 1,1,1-TCE, CFC-113 (1,1,1-TCE, CFC-113 대체세정제를 이용한 스크린인쇄 세정연구)

  • Lee, Ki-Chang;Yoon, Cheol-Hun;Hwang, Sung-Kwy;Oh, Se-Young;Lee, Seok-Woo;Ryu, Jung-Wok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • The field of printing use to pressurization ink using screen gassamer that is called screen printing. Existing cleaning solvent using screen printing are the organic solvents including aromatic compounds carried with poisonous and stench. Besides, cleaning method of current screen printing are for the most part mixed cleaning method of dipping and polish. Using 1,1,1-TCE, CFC-113 alternative system cleaning solvent be substituted for existing cleaning solvent against screen printing ink measured the cleaning efficiency according to gravimetric analysis method and property change of gassamer according to Image Analyzer. Also, Cleaning process system carry with excellent cleaning efficiency studied which was proposed new cleaning process including ultrasonic and vibration cleaning process be substituted for existing mixed cleaning method of dipping and polish.

Laboratory Findings and Subjective Symptoms of Car Repair Workers (자동차 정비공의 혈액 및 뇨검사 소견과 자각증상에 대한 조사)

  • 이광성;이명구;조영채
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.80-87
    • /
    • 1998
  • To evaluate the effects on health by exposure to low dose organic solvents, the author analyzed the air concentration of mixed organic solvents (toluene, xylene, butylacetate) at worker's breathing zone during painting, some laboratory findings of blood (WBC, RBC, Hb, Hct, SGOT, SGPT, TC, TG, HDL-C, LDL-C, IgG, IgM, IgA and IgE) and urine (hippuric acid, urinary protein, urobilinogen), surveyed the subjective symptoms those were obtained from 35 male workers exposed to mixed organic solvents, and 25 male workers not exposed to organic solvents who worked in car repair workshops in Taejon area from December 1, 1995, to February 29, 1996. The results were as follows: 1. The mean concentration of urinary hippuric acid of car painting worker group (organic solvent exposure group) was 0.76$\pm$ 0.21 g/l, which is significantly higher than that of non-exposed group. 2. In hematologic findings, the values of RBC, TC, LDL-C, IgG and IgE in the exposure group were significantly lower than those of the nonexposed group, but SGOT and SGPT in the exposure group were significantly higher than those of the non-exposed group. 3. Urinary hippuric acid levels showed positively correlated with toluene, urobilinogen and HDL-C levels, but those were negatively correlated with RBC, LDL-C, IgM levels. 4. Rates of the subjective symptoms such as "dizziness", "appetite loss", "weight loss", "palpitation", "chest tightness", "sore throat and eye discomfort", "tingling sense and acrodynia", "illusion or hallucination" and "decreaased motor power" were significantly higher in the exposure group than those of the non-exposed group.

  • PDF